Difference between revisions of "RadiMationInterface.can"

From RadiWiki
Jump to: navigation, search
(Test_Frequency_Modulation_Internal)
(Test_Amplitude_Modulation_Internal)
Line 55: Line 55:
 
'''Unit parameter:''' dBm
 
'''Unit parameter:''' dBm
 
==Test_Amplitude_Modulation_Internal==
 
==Test_Amplitude_Modulation_Internal==
The modulation in the signal generator is configured as internal frequency modulation.
+
The modulation in the signal generator is configured as internal amplitude modulation.
  
 
'''Parameter1:''' mdFreqency
 
'''Parameter1:''' mdFreqency
Line 66: Line 66:
  
 
{{note|The modulation may not be active at this moment, [[#Test_Modulation_On|Test_Modulation_On]] is the event called when the modulation is turned on.}}
 
{{note|The modulation may not be active at this moment, [[#Test_Modulation_On|Test_Modulation_On]] is the event called when the modulation is turned on.}}
 +
 
==Test_Amplitude_Modulation_External==
 
==Test_Amplitude_Modulation_External==
 
The modulation in the signal generator is configured as external amplitude modulation.
 
The modulation in the signal generator is configured as external amplitude modulation.

Revision as of 10:23, 28 October 2010

The RadiMationInterface.can is an interface between the RadiMation software and CANoe and CANalyser.

By inserting this file inside your CANoe/CANalyser project you are able to extract information from RadiMation using CANoe/CANalyser.

You can download the file here

Explanation of available events/functions

Test_Frequency

The current frequency of the test, in other words the frequency of the signal generator.

Parameter: mdFreqMHz

Unit parameter: MHz

Test_Carrier_Level

The carrier level of the signal generator

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Forward_Power

The measured value of the forward power.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Reflected_Power

The measured value of the reflected power.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Average_Field

The measured value of the average field.

Parameter: mdFieldVm

Unit parameter: V/m

Test_Calculated_Field

The calculated value of the field based on the calibration file.

Parameter: mdFieldVm

Unit parameter: V/m

Test_Measured_Current

The measured value of the current.

Parameter: mdCurrentInmA

Unit parameter: mA

Test_Sensor_Power

The measured power of by the current sensor power meter.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Amplitude_Modulation_Internal

The modulation in the signal generator is configured as internal amplitude modulation.

Parameter1: mdFreqency

Unit parameter1: Hz

Parameter2: mdDepth

Unit parameter2: %

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Amplitude_Modulation_External

The modulation in the signal generator is configured as external amplitude modulation.

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Frequency_Modulation_Internal

The modulation in the signal generator is configured as internal frequency modulation.

Parameter1: mdFreqency

Unit parameter1: Hz

Parameter2: mdDepth

Unit parameter2: %

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Frequency_Modulation_External

The modulation in the signal generator is configured as external frequency modulation.

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Pulse_Modulation_Internal

Test_Pulse_Modulation_External

The modulation in the signal generator is configured as external pulse modulation.

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Modulation_On

The currently configured modulation is turned on.

Test_Modulation_Off

The current configured modulation is turned off.

Antenna_Movement_Started

Starting of the movement of the antenna tower with the target position of the antenna tower.

Parameter: position

Unit parameter: Meter

Antenna_Movement_Stopped

The stop position of the antenna tower.

Parameter: position

Unit parameter: Meter

Antenna_Movement_Percentage

The current percentage of the antenna tower movement from the start position to the end position

Parameter: percentage

Unit parameter: %

Antenna_Movement_Changing_Polarisation

Changing the antenna polarisation.

Parameter: target

Unit parameter: unitless

When the target is 1 the antenna is changed to horizontal.

When the target is 2 the antenna is changed to vertical.

TurnTable_Movement_Started

Starting of the movement of the turn table with the target position of the turn table.

Parameter: position

Unit parameter: Degrees

TurnTable_Movement_Stopped

The stop position of the turn table.

Parameter: position

Unit parameter: Degrees

TurnTable_Movement_Turning_Percentage

The current percentage of the turn table movement from the start position to the end position

Parameter: percentage

Unit parameter: %