RadiMationInterface.can

From RadiWiki
Revision as of 13:21, 15 February 2019 by Joro (talk | contribs)
Jump to: navigation, search

The RadiMationInterface.can file a CANoe CAPL file that provides specifically named CAPL functions that are called from the RadiMation® software. Those CAPL functions are used to generate an interface to provide measurement values from the RadiMation® software to the CANoe software.

By including this RadiMationInterface.can file inside your CANoe project, it will be possible to get updates of the RadiMation® measurement values.

You can download the RadiMationInterface.can file here

For more details on how to use and attach this file in your CANoe project, please see then CANoe page.

Information.png
Note: The CANoe Switch Matrix device driver is not able to determine if a specifically named CAPL function is existing in the running CANoe environment.

When one or more of the specifically named CAPL functions from the RadiMationInterface.can file, is not implemented, the function call is being forwarded to the CANoe software itself, and there will be no error message or return value. The CANoe Switch Matrix is thus not able to warn or raise an error when one or more of the specifically called CAPL functions is not implemented.

Explanation of available events/functions

Test_Frequency

The current frequency of the test, in other words the frequency of the signal generator.

Parameter: mdFreqMHz

Unit parameter: MHz

Test_Carrier_Level

The carrier level of the signal generator

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Forward_Power

The measured value of the forward power.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Reflected_Power

The measured value of the reflected power.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Net_Power

The measured value of the netto power.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Average_Field

The measured value of the average field.

Parameter: mdFieldVm

Unit parameter: V/m

Test_Calculated_Field

The calculated value of the field based on the calibration file.

Parameter: mdFieldVm

Unit parameter: V/m

Test_Measured_Current

The measured value of the current.

Parameter: mdCurrentInmA

Unit parameter: mA


Test_Calculated_Current

The calculated value of the current.

Parameter: mdCurrentInmA

Unit parameter: mA

Test_Sensor_Power

The measured power of by the current sensor power meter.

Parameter: mdPowerIndBm

Unit parameter: dBm

Test_Amplitude_Modulation_Internal

The modulation in the signal generator is configured as internal amplitude modulation.

Parameter1: mdFreqency

Unit parameter1: Hz

Parameter2: mdDepth

Unit parameter2: %

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Amplitude_Modulation_External

The modulation in the signal generator is configured as external amplitude modulation.

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Frequency_Modulation_Internal

The modulation in the signal generator is configured as internal frequency modulation.

Parameter1: mdFreqency

Unit parameter1: kHz

Parameter2: dmShift

Unit parameter2: kHz

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Frequency_Modulation_External

The modulation in the signal generator is configured as external frequency modulation.

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Pulse_Modulation_Internal

The modulation in the signal generator is configured as internal pulse modulation.

Parameter1: mdFreqency

Unit parameter1: kHz

Parameter2: mdWidth

Unit parameter2: %

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Pulse_Modulation_External

The modulation in the signal generator is configured as external pulse modulation.

Information.png
Note: The modulation may not be active at this moment, Test_Modulation_On is the event called when the modulation is turned on.

Test_Modulation_On

The currently configured modulation is turned on.

Test_Modulation_Off

The current configured modulation is turned off.

Test_DwellTime_Start

The currently dwelltime has started.

Test_DwellTime_Stop

The currently dwelltime has stopped.

Antenna_Movement_Started

Starting of the movement of the antenna tower with the target position of the antenna tower.

Parameter: position

Unit parameter: Meter

Antenna_Movement_Stopped

The stop position of the antenna tower.

Parameter: position

Unit parameter: Meter

Antenna_Movement_Percentage

The current percentage of the antenna tower movement from the start position to the end position

Parameter: percentage

Unit parameter: %

Antenna_Movement_Changing_Polarisation

Changing the antenna polarisation.

Parameter: target

Unit parameter: unitless

When the target is 1 the antenna is changed to horizontal.

When the target is 2 the antenna is changed to vertical.

Antenna_Polarisation_Changed

Notification that the changing of the antenna polarisation has finished.

Parameter: target

Unit parameter: unitless

When the target is 1 the antenna is changed to horizontal.

When the target is 2 the antenna is changed to vertical.

TurnTable_Movement_Started

Starting of the movement of the turn table with the target position of the turn table.

Parameter: position

Unit parameter: Degrees

TurnTable_Movement_Stopped

The stop position of the turn table.

Parameter: position

Unit parameter: Degrees

TurnTable_Movement_Turning_Percentage

The current percentage of the turn table movement from the start position to the end position

Parameter: percentage

Unit parameter: %