= How to use the {{RadiCentre}} safety interlock system in {{RadiMation}} =
 
= How to use the {{RadiCentre}} safety interlock system in {{RadiMation}} =
 +
{{Warning|This page is a draft}}
 +
 
This application note describes how {{RadiMation}} can be configured to make optimal use of the safety interlock system that is available on the {{RadiCentre}}.
 
This application note describes how {{RadiMation}} can be configured to make optimal use of the safety interlock system that is available on the {{RadiCentre}}.
  
 +
== Hardware setup. ==
 +
The rf switch card in the RadiCentre has an interlock input which must be connected to all safety switches (doors etc). Typically the "A" relay is switched to NC when the interlock is not closed. Also in the case the interlock is not closed, {{Radimation}} will not start a test.
 +
 +
=== Schematic overview of interlock relay. ===
 +
 +
In this schema we can see that we are using 7A, 7 for the 7th slot in {{Radimation}} and A for the relay.
 +
 +
[[File:interlock_schema.jpg]]
 +
 +
Picture of the backside of the RadiCentre:
 +
 +
[[File:interlock-radicentre-back.jpg]]
 +
 +
== Configure RadiMation. ==
 +
In this example we are going to configure a RSW1024S switch card.
 +
 +
Open {{Radimation}}
 +
Open the menu:
 +
{{Menu|Test-sites|Configure...}}
 +
 +
At test equipment select the applicable test-site
 +
 +
[[File:interlock-select-testsite.jpg]]
 +
 +
Right click on the switch matrix and select the applicable driver.
 +
 +
[[File:interlock-select-driver]]
 +
 +
== Driver configuration ==
 +
Select the tab "Switches"
 +
Configure on the “During” tab relay A to “Normally open”
 +
Configure on the “After” tab, Relay A to “Normally closed”
 +
 +
[[File:interlock-driver-switches.jpg]]
  
 
[[Category:RadiMation Application Note]]
 
[[Category:RadiMation Application Note]]
 
[[Category:RadiMation]]
 
[[Category:RadiMation]]

Revision as of 09:39, 25 February 2019

How to use the RadiCentre® safety interlock system in RadiMation®

Warning-48px.png
Warning: This page is a draft

This application note describes how RadiMation® can be configured to make optimal use of the safety interlock system that is available on the RadiCentre®.

Hardware setup.

The rf switch card in the RadiCentre has an interlock input which must be connected to all safety switches (doors etc). Typically the "A" relay is switched to NC when the interlock is not closed. Also in the case the interlock is not closed, RadiMation® will not start a test.

Schematic overview of interlock relay.

In this schema we can see that we are using 7A, 7 for the 7th slot in RadiMation® and A for the relay.

File:Interlock schema.jpg

Picture of the backside of the RadiCentre:

Interlock-radicentre-back.jpg

Configure RadiMation.

In this example we are going to configure a RSW1024S switch card.

Open RadiMation® Open the menu:

   Menu.png Test-sites
      Menu.png Configure...

At test equipment select the applicable test-site

File:Interlock-select-testsite.jpg

Right click on the switch matrix and select the applicable driver.

File:Interlock-select-driver

Driver configuration

Select the tab "Switches" Configure on the “During” tab relay A to “Normally open” Configure on the “After” tab, Relay A to “Normally closed”

File:Interlock-driver-switches.jpg