The factory for the persistable object (identifier ") is not registered. The file is probably corrupt, or it is created with a newer version of the software.

After a new RadiMation version is installed it could be that the customize file modified with a newer version of the software, which is the cause that it is corrupted in the older version.

Solution

This error is raised because a file that is shared by both versions is written in a newer file format that cannot be read anymore by version 5.8. The solution for this problem is to remove the file: (C:\Program Files\DARE Development\RadiMation\) Confdvdr\customiz.dat file. The customiz.dat file is used to remember customization's of the color of the graphs, so removing the file will not influence the measurements. However the graph colors will probably be changed to the defaults as specified by RadiMation®.