RadiMation Error: 805309372

From RadiWiki
Revision as of 12:48, 2 March 2021 by Roge (talk | contribs) (Created page with "= Measuring at 150 kHz in a sweep with an activated "preselector" is not possible. Create a band below 150 kHz and a band above 150 kHz. = The R&S ESI analyser won't allow to...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Measuring at 150 kHz in a sweep with an activated "preselector" is not possible. Create a band below 150 kHz and a band above 150 kHz.

The R&S ESI analyser won't allow to set a start frequency below 150 kHz and end frequency at 150 kHz or higher with the preselector enabled.

Possible solutions

  • Create a multiband test with a band to max 149 kHz and one band from 150 kHz and higher.
  • Wen not using a multiband test, then create two tests.