Difference between revisions of "RadiMation Error: 805329475"

From RadiWiki
Jump to: navigation, search
(Created page with '= The requested carrier level is higher than the maximum (<1> dBm) that is allowed with AM Modulation. AM Modulation is not activated. = An AM modulated signal power value is req…')
 
 
Line 1: Line 1:
 
= The requested carrier level is higher than the maximum (<1> dBm) that is allowed with AM Modulation. AM Modulation is not activated. =
 
= The requested carrier level is higher than the maximum (<1> dBm) that is allowed with AM Modulation. AM Modulation is not activated. =
An AM modulated signal power value is requested from the [[DARE!! Instruments]] RadiGen, which is higher than the maximum allowed AM modulated carrier level.
+
An AM modulated signal power value is requested from the [[Raditeq]] RadiGen, which is higher than the maximum allowed AM modulated carrier level.
 
The maximum allowed AM Modulated carrier level is shown in the error message as the location of '<1>'.
 
The maximum allowed AM Modulated carrier level is shown in the error message as the location of '<1>'.
  

Latest revision as of 11:36, 9 September 2022

The requested carrier level is higher than the maximum (<1> dBm) that is allowed with AM Modulation. AM Modulation is not activated.

An AM modulated signal power value is requested from the Raditeq RadiGen, which is higher than the maximum allowed AM modulated carrier level. The maximum allowed AM Modulated carrier level is shown in the error message as the location of '<1>'.

Solution

Possible solutions for this error can be:

  • Reduce the required test-level.
  • Do not use AM modulation.
  • Include a maximum amplifier input correction, at the specified level.