+ | The {{ScreenElement|Switches}} tab allows to configure the actual state of the relay on the switch card. | ||
{{ScreenElementDescriptionStart}} | {{ScreenElementDescriptionStart}} |
Revision as of 10:46, 9 January 2024
The Raditeq RSW2002E device driver is a Switch Matrix which is supported by RadiMation®.
On the Communication tab, the desired communication method can be selected and configured. Depending on the selected method, additional relevant settings are shown and can be configured.
Communication Streams | Selects the medium or method that should be used to communicate with the device. Depending on the capabilities of the device this can be one or more of:
See the Communication Settings in Chapter 15, on how to configure each of these methods. |
On the Identification tab, the expected *IDN? response of the test and measurement device can be configured. It is used to determine if the correct test and measurement device is connected.
Expected response | The expected *IDN? response of a device. It can be changed in the case the commands are the same for another device for which no RadiMation® driver is available yet. |
Restore default | Restores the original Exepected response. |
There are several methods in which the Raditeq RSW2002E can be connected to the PC. The Raditeq RSW2002E can for example be connected directly to the PC, or through a plugincard in a RadiCentre 1 or a multi-slot RadiCentre. More information on how to use the RadiCentre is present in the product manual of the RadiCentre. The settings on the RadiCentre tab can be used to specify how the Raditeq RSW2002E is connected.
When the Raditeq RSW2002E is connected to a multi-slot RadiCentre, also the slot number in which the plugincard is fitted, should be specified.
Directly to PC | Specifies that the Raditeq RSW2002E is connected directly to the PC, without the use of a RadiCentre. |
RadiCentre 1 | Specifies that the Raditeq RSW2002E is connected to a plugincard that is fitted in a RadiCentre 1. |
RadiCentre Multi-slot | Specifies that the Raditeq RSW2002E is connected to a plugincard that is fitted in a multi-slot RadiCentre. |
Device ID | Specifies the slot in the multi-slot RadiCentre in which the plugincard of the Raditeq RSW2002E is fitted. |
The settings on this RadiCentre tab, only specifies if and which RadiCentre is used. The communication settings on the Communication tab specify the connection settings to communication with the measurement device.
The configuration on the Communication tab should be configured depending on the outgoing connection from the PC. Thus if Directly to PC is selected, the communication settings should be configured as what is actually used between the PC and the Raditeq RSW2002E itself. If RadiCentre 1 or RadiCentre Multi-slot is selected, the communication settings should be configured as what is actually used between the PC and the RadiCentre. In the configuration where a RadiPower is connected with USB to a Multi-slot RadiCentre, which is connected by GPIB to the PC, the communication settings of the RadiPower device driver should thus be GPIB.
If the Raditeq RSW2002E is for example connected to slot 3 of a multi-slot RadiCentre which has IP address 192.168.178.95 and is connected by LAN to the PC, the following settings should be configured in the device driver of the Raditeq RSW2002E:
- RadiCentre tab
- Connection type: RadiCentre Multi-slot
- Device ID: 3
- Communication tab
- Communication Stream: VISA
- LAN: 192.168.178.95
The Software update tab can be used to update the firmware of the Raditeq RSW2002E.
Firmware | Specifies the filename of the firmware update file that should be used to update the firmware of the measurement device. |
Browse | Allows to select the firmware update file. |
Update Firmware | Starts the actual firmware update. First some checks are performed, and if those checks are successful, the actual firmware update is performed. |
Status | Shows a message during the firmware update, indicating the performed action and the actual status. |
The Switches tab allows to configure the actual state of the relay on the switch card.
During and After |
There are two switch configurations. These two configurations are during and after the test. The settings on the During tab are send to the switch matrix just before the test is started. The settings on the After tab are send to the switch matrix after the test has ended.
|