== RadiMation version 2015.1.6 ==
 
== RadiMation version 2015.1.6 ==
 +
* #4598: Driver PMM9010F
 +
* #4947: Diagram description in dBuA/m with Magnetic field setting
 +
* #5155: Driver PMM9010F
 
* #5369: RadiMation crashes when SRQ line is busy
 
* #5369: RadiMation crashes when SRQ line is busy
 
* #5594: Driver Agilent Power Meters U2000H, U2000B and U2002A
 
* #5594: Driver Agilent Power Meters U2000H, U2000B and U2002A
 +
* #5641: Signal power went to high errors with Gigatronic 8542C powermeter
 +
* #5645: Peak measurements give different results
 
* #5841: MXE receiver N9038 is not starting performing the measurement
 
* #5841: MXE receiver N9038 is not starting performing the measurement
 
* #5843: First point of forward powermeter (Advantest analyser) measurement is wrong
 
* #5843: First point of forward powermeter (Advantest analyser) measurement is wrong
* #5844: Advantest analyzer as powermeter is not automatically switching the attenuator
+
* #5844: Advantest analyser as powermeter is not automatically switching the attenuator
 
* #5847: RadiField field verification
 
* #5847: RadiField field verification
 
* #5883: ESL 6 quasi-peak measurement gets stuck
 
* #5883: ESL 6 quasi-peak measurement gets stuck
 +
* #5907: Error detected during the start of the sweep with PMM 9010 F
 +
* #5919: Unexpected power readings with RPR3006W Powermeter
 
* #5932: RIGOL DSA 815 AVG and QP measurements are showing differences compared to manual measurements
 
* #5932: RIGOL DSA 815 AVG and QP measurements are showing differences compared to manual measurements
 
* #5933: Regulation in the Multiband Immunity test is not increasing the power to satisfy both Testlevels
 
* #5933: Regulation in the Multiband Immunity test is not increasing the power to satisfy both Testlevels
Line 12: Line 19:
 
* #5945: RIGOL DSA 815 timeout and query interrupted
 
* #5945: RIGOL DSA 815 timeout and query interrupted
 
* #5948: When opening test data a Run-time error '91' Object variable or With block variable not set is shown
 
* #5948: When opening test data a Run-time error '91' Object variable or With block variable not set is shown
* #5949: Driver AR Field Analyzer 7006 read out
+
* #5949: Driver AR Field Analyser 7006 read out
 +
* #5951: RadiMation crash during startup
 
* #5955: Drivers AR DC2500AM1, DC7128A, DC7420M1, DC7530 and DC 7620
 
* #5955: Drivers AR DC2500AM1, DC7128A, DC7420M1, DC7530 and DC 7620
 
* #5957: Driver AR 40T26G40A
 
* #5957: Driver AR 40T26G40A
 
* #5958: Drivers Antennas ATEK30MM1, ATL80M1G, ATH18G27, ATH26G40
 
* #5958: Drivers Antennas ATEK30MM1, ATL80M1G, ATH18G27, ATH26G40
 +
* #5965: What is the difference between the average value and the measurement value of the used field probe?
 +
* #5966: Why is the setting of the frequency range missing in the driver window?
 +
* #5972: When is the CAL calibration file needed to be used
 +
* #5979: What is the External Dwell Time and how is it working?

Latest revision as of 09:30, 3 January 2020

RadiMation version 2015.1.6

  • #4598: Driver PMM9010F
  • #4947: Diagram description in dBuA/m with Magnetic field setting
  • #5155: Driver PMM9010F
  • #5369: RadiMation crashes when SRQ line is busy
  • #5594: Driver Agilent Power Meters U2000H, U2000B and U2002A
  • #5641: Signal power went to high errors with Gigatronic 8542C powermeter
  • #5645: Peak measurements give different results
  • #5841: MXE receiver N9038 is not starting performing the measurement
  • #5843: First point of forward powermeter (Advantest analyser) measurement is wrong
  • #5844: Advantest analyser as powermeter is not automatically switching the attenuator
  • #5847: RadiField field verification
  • #5883: ESL 6 quasi-peak measurement gets stuck
  • #5907: Error detected during the start of the sweep with PMM 9010 F
  • #5919: Unexpected power readings with RPR3006W Powermeter
  • #5932: RIGOL DSA 815 AVG and QP measurements are showing differences compared to manual measurements
  • #5933: Regulation in the Multiband Immunity test is not increasing the power to satisfy both Testlevels
  • #5937: Driver: Rigol DSG3060
  • #5945: RIGOL DSA 815 timeout and query interrupted
  • #5948: When opening test data a Run-time error '91' Object variable or With block variable not set is shown
  • #5949: Driver AR Field Analyser 7006 read out
  • #5951: RadiMation crash during startup
  • #5955: Drivers AR DC2500AM1, DC7128A, DC7420M1, DC7530 and DC 7620
  • #5957: Driver AR 40T26G40A
  • #5958: Drivers Antennas ATEK30MM1, ATL80M1G, ATH18G27, ATH26G40
  • #5965: What is the difference between the average value and the measurement value of the used field probe?
  • #5966: Why is the setting of the frequency range missing in the driver window?
  • #5972: When is the CAL calibration file needed to be used
  • #5979: What is the External Dwell Time and how is it working?