(RadiMation version 2018.2.1)
Line 5: Line 5:
 
* #7794: Compression Gain System Calibration when saved it removes rest of suggested name discription after any.
 
* #7794: Compression Gain System Calibration when saved it removes rest of suggested name discription after any.
 
* #7869: Y axis scaling in graph improvements
 
* #7869: Y axis scaling in graph improvements
 +
* #8021: When a Band has been selected the TSF is marked as being changed
 
* #8148: Modification to Monitoring input channel sometimes reset the configured channel to 1
 
* #8148: Modification to Monitoring input channel sometimes reset the configured channel to 1
 +
* #8149: Graph Customization Configuration of the global graph color settings outside a test is not updating the global settings
 +
* #8158: Multiband Emission TSF configuration is not using the maximum number of selectable detectors
 +
* #8263: Opening non existing file with RadiLog crash Gives exception
 +
* #8265: Confirmation message is default selecting wrong answer (No) instead of Yes
 
* #8272: General Information in a calibration file cannot be shown if the calibration file is readonly
 
* #8272: General Information in a calibration file cannot be shown if the calibration file is readonly
 
* #8283: A 'Copy to Clipboard' action is marking a COR file as being changed
 
* #8283: A 'Copy to Clipboard' action is marking a COR file as being changed
 +
* #8290: System Calibration Attenuation / Gain Message shows message to connect the sensor power, but requires a forward powermeter in test equipment
 
* #8380: Selecting a field probe in a testsite takes more than 20 seconds
 
* #8380: Selecting a field probe in a testsite takes more than 20 seconds
 +
* #8587: Changing graph customizations is not setting the changed state of the test
 
* #8757: Not possible to edit MB EFT test from the sequence window
 
* #8757: Not possible to edit MB EFT test from the sequence window
 
* #8864: Graphs of gain compression calibration are not showing all the data
 
* #8864: Graphs of gain compression calibration are not showing all the data
Line 19: Line 26:
 
* #8948: Not all calibration tests are listed in the add test function of the sequence.
 
* #8948: Not all calibration tests are listed in the add test function of the sequence.
 
* #9002: Also show the latest DRIVERS.EXE version on the RadiWiki Main page
 
* #9002: Also show the latest DRIVERS.EXE version on the RadiWiki Main page
 +
* #9032: Harmonics show -1000dBm
 
* #9062: Measurement of Harmonics with 2 power meters
 
* #9062: Measurement of Harmonics with 2 power meters
 
* #9082: RadiMation calibration expire date database error crash
 
* #9082: RadiMation calibration expire date database error crash
Line 26: Line 34:
 
* #9202: Adding input fieldprobe without enabling any probe in RI MB test, is causing object reference
 
* #9202: Adding input fieldprobe without enabling any probe in RI MB test, is causing object reference
 
* #9218: Infinit loop graph elements being added for gain calibration test
 
* #9218: Infinit loop graph elements being added for gain calibration test
 +
* #9219: Cannot find the device driver - (Device is not on - Device driver is installed)
 
* #9224: In ErrorReport an unknown label 'usr agr' is present
 
* #9224: In ErrorReport an unknown label 'usr agr' is present
 +
* #9232: Emission peak number not correct
 
* #9242: Exception is shown when EUT Monitoring input is opened
 
* #9242: Exception is shown when EUT Monitoring input is opened
 
* #9246: Script for copying latest RadiMation release to Radi-Products Production folder
 
* #9246: Script for copying latest RadiMation release to Radi-Products Production folder
 
* #9248: Readonly Network Analyzer system calibration still has some fields enabled
 
* #9248: Readonly Network Analyzer system calibration still has some fields enabled
 
* #9250: Number of sweeps in TSF of Network Analyzer EUT Calibration is not correctly initialized
 
* #9250: Number of sweeps in TSF of Network Analyzer EUT Calibration is not correctly initialized
 +
* #9267: Continue button does not work
 
* #9300: How to show the points only that have the status 'fail'  
 
* #9300: How to show the points only that have the status 'fail'  
 
* #9301: ErrorReport: "ETS-Lindgren EMField 7008-005 FWD power: Parameter too low"
 
* #9301: ErrorReport: "ETS-Lindgren EMField 7008-005 FWD power: Parameter too low"
 +
* #9303: ErrorReport: "Radimation crashes suddenly after CE measurement is finished "
 
* #9312: EMI reciver switch to spectrum analyzermode while initialisation for conducted emission testing
 
* #9312: EMI reciver switch to spectrum analyzermode while initialisation for conducted emission testing
 +
* #9315: Auto Backup of RadiLog
 
* #9323: SystemCrash: Source array was not long enough. Check srcIndex and length, and the array's lower bounds.
 
* #9323: SystemCrash: Source array was not long enough. Check srcIndex and length, and the array's lower bounds.
 
* #9333: ErrorReport: "Cannot find the device driver.
 
* #9333: ErrorReport: "Cannot find the device driver.

Revision as of 13:40, 5 September 2018

RadiMation version 2018.2.1

  • #4670: Building the 'TestSites' menu can take a long time
  • #4777: Printing the angle plot of a Multiband emission test is printing the frequency graph
  • #6529: Version numbers in the Device driver DLL's should use the build number that is used, also if adjusted to the SVN revision
  • #7794: Compression Gain System Calibration when saved it removes rest of suggested name discription after any.
  • #7869: Y axis scaling in graph improvements
  • #8021: When a Band has been selected the TSF is marked as being changed
  • #8148: Modification to Monitoring input channel sometimes reset the configured channel to 1
  • #8149: Graph Customization Configuration of the global graph color settings outside a test is not updating the global settings
  • #8158: Multiband Emission TSF configuration is not using the maximum number of selectable detectors
  • #8263: Opening non existing file with RadiLog crash Gives exception
  • #8265: Confirmation message is default selecting wrong answer (No) instead of Yes
  • #8272: General Information in a calibration file cannot be shown if the calibration file is readonly
  • #8283: A 'Copy to Clipboard' action is marking a COR file as being changed
  • #8290: System Calibration Attenuation / Gain Message shows message to connect the sensor power, but requires a forward powermeter in test equipment
  • #8380: Selecting a field probe in a testsite takes more than 20 seconds
  • #8587: Changing graph customizations is not setting the changed state of the test
  • #8757: Not possible to edit MB EFT test from the sequence window
  • #8864: Graphs of gain compression calibration are not showing all the data
  • #8881: Graphs of amplifier linearity calibration cannot be shown in Watts unit
  • #8882: Better auto scaling for the y-axis of the amplifier linearity graphs
  • #8892: Wrong title Harmonics calibration
  • #8893: Harmonics test graphs does not use stored graph settings
  • #8904: Suggested filename for the calibration is not correct if the TSF contains a .
  • #8941: ctlEvents.cs is included twice and seems to be duplicated
  • #8948: Not all calibration tests are listed in the add test function of the sequence.
  • #9002: Also show the latest DRIVERS.EXE version on the RadiWiki Main page
  • #9032: Harmonics show -1000dBm
  • #9062: Measurement of Harmonics with 2 power meters
  • #9082: RadiMation calibration expire date database error crash
  • #9115: Temp filenames in creating new files
  • #9125: Pressing update in graph config does not update the image.
  • #9186: Suggested filename of a calibration file is only 'm.cal' if the TSF description is: "80-1000 MHz, 10 V/m"
  • #9202: Adding input fieldprobe without enabling any probe in RI MB test, is causing object reference
  • #9218: Infinit loop graph elements being added for gain calibration test
  • #9219: Cannot find the device driver - (Device is not on - Device driver is installed)
  • #9224: In ErrorReport an unknown label 'usr agr' is present
  • #9232: Emission peak number not correct
  • #9242: Exception is shown when EUT Monitoring input is opened
  • #9246: Script for copying latest RadiMation release to Radi-Products Production folder
  • #9248: Readonly Network Analyzer system calibration still has some fields enabled
  • #9250: Number of sweeps in TSF of Network Analyzer EUT Calibration is not correctly initialized
  • #9267: Continue button does not work
  • #9300: How to show the points only that have the status 'fail'
  • #9301: ErrorReport: "ETS-Lindgren EMField 7008-005 FWD power: Parameter too low"
  • #9303: ErrorReport: "Radimation crashes suddenly after CE measurement is finished "
  • #9312: EMI reciver switch to spectrum analyzermode while initialisation for conducted emission testing
  • #9315: Auto Backup of RadiLog
  • #9323: SystemCrash: Source array was not long enough. Check srcIndex and length, and the array's lower bounds.
  • #9333: ErrorReport: "Cannot find the device driver.
  • #9334: ErrorReport: "Startfrequenz ist zu niedrig fuer das gewaehlte Geraet"
  • #9340: Driver: Shaffner Broadband Horn Antenna 1-18 GHZ - BHA 9118
  • #9353: Popup menu of available devices has no seperator between the actions and the devices
  • #9358: Radimation crashes when device is in use by other software
  • #9372: How to remote control LISN R&S ENV216 with the R&S ESW 26 via radimation
  • #9373: Rohde & Schwarz SMR 20 (ID7340): Specific System Error: 110,"Output unleveled"
  • #9389: How do we set-up for testing acording EN6100-3-2 and EN 61000-3-3
  • #9390: The file extensions of the template and the output document do not match