== RadiMation version 2022.2.2 ==
 
== RadiMation version 2022.2.2 ==
 +
* #4601: Report, view and compare improvements for CAL files
 +
* #5742: Determination of % out of 6dB error after UFA calculation
 +
* #5936: Possibility to generate a report of a calibration with Report Generator
 +
* #8586: Milmega 80RF1000-175 amplifier is not switching.
 
* #9626: Driver: ETS-Lindgren 2090
 
* #9626: Driver: ETS-Lindgren 2090
 
* #12686: Wrong test level if order is tick checkbox/change testlevel.
 
* #12686: Wrong test level if order is tick checkbox/change testlevel.
 +
* #12765: Extend Uniform Field Area (UFA) calculation to include statistical information
 +
* #12767: Calculate statistical information of UFA calculation.
 +
* #12769: Show the result of statistical information of the UFA calculation on the UFA result window.
 +
* #12770: Include report generator codes to include Statistical information in the report
 +
* #12771: Update standard printout of UFA calculation to includes the calculated statistical information:
 +
* #12861: Milmega 80RF1000 does not switch.
 
* #12957: The Note and Units buttons are not shown on the UFA result window.
 
* #12957: The Note and Units buttons are not shown on the UFA result window.
 
* #12988: The maximum tolerance of the UFA calculation is not shown if it is all below the accepted tolerance
 
* #12988: The maximum tolerance of the UFA calculation is not shown if it is all below the accepted tolerance
Line 9: Line 19:
 
* #13000: N9322C Fails
 
* #13000: N9322C Fails
 
* #13002: Remove code related to HP3478A from Fluke 8840 driver
 
* #13002: Remove code related to HP3478A from Fluke 8840 driver
 +
* #13003: Show the number of device drivers on the RadiWiki website
 +
* #13092: Can the QP detector value be shown in the peak table if the QP detector has been used in the measurement?
 +
* #13094: Columns hidden from the detected peak table are still shown in the report

Latest revision as of 08:58, 24 October 2022

RadiMation version 2022.2.2

  • #4601: Report, view and compare improvements for CAL files
  • #5742: Determination of % out of 6dB error after UFA calculation
  • #5936: Possibility to generate a report of a calibration with Report Generator
  • #8586: Milmega 80RF1000-175 amplifier is not switching.
  • #9626: Driver: ETS-Lindgren 2090
  • #12686: Wrong test level if order is tick checkbox/change testlevel.
  • #12765: Extend Uniform Field Area (UFA) calculation to include statistical information
  • #12767: Calculate statistical information of UFA calculation.
  • #12769: Show the result of statistical information of the UFA calculation on the UFA result window.
  • #12770: Include report generator codes to include Statistical information in the report
  • #12771: Update standard printout of UFA calculation to includes the calculated statistical information:
  • #12861: Milmega 80RF1000 does not switch.
  • #12957: The Note and Units buttons are not shown on the UFA result window.
  • #12988: The maximum tolerance of the UFA calculation is not shown if it is all below the accepted tolerance
  • #12989: Wrong unit is shown at maximum deviation frequency on printout of uniform field area calculation.
  • #12996: Reading a binary block buffer results in a time out when using VISA Socket communication
  • #12999: N9322C Fails
  • #13000: N9322C Fails
  • #13002: Remove code related to HP3478A from Fluke 8840 driver
  • #13003: Show the number of device drivers on the RadiWiki website
  • #13092: Can the QP detector value be shown in the peak table if the QP detector has been used in the measurement?
  • #13094: Columns hidden from the detected peak table are still shown in the report