RadiMation version 5.6.2

  • #2134: AD Convertor device driver that monitors received measurement values on the serial port
  • #2447: Emco 2090 driver update after install
  • #2645: Call was rejected by the callie
  • #3028: option to remove the overrange warning from the 4455 driver
  • #3053: Driver: Pmm 8051 + probe BA05
  • #3423: the "Print Report"-Box in the Report Generator is activated by default.
  • #3479: driver: PMM EP600
  • #3481: Import rsus substitution file is incorrect
  • #3482: Release note is not generated in the automated build scripts
  • #3486: FSEM 30 Input 1 and input 2 are incorrect because the device only has 1 input.
  • #3488: Multi band manual mode generates an error of start stop frequency during the init of the test

RadiMation version 5.6.1

  • #3478: An error message is shown when the configuration window of the Agilent 4440 is closed
  • #3477: Using a sub template as an template for reporting after the tests results in an empty graph
  • #3472: Sorting peaks according to numbers does not work correctly
  • #3470: peaks wrongly detected & merged graphs wrongly displayed
  • #3469: Limitation of net-power instead of forward power
  • #3466: Second band of a emission multiband test is using the same step frequency as the first band
  • #3464: Crash (error 91) when the configuration window is closed
  • #3463: Kalmus 757LC amplifier is not working. Test seems to hang
  • #3462: SMA100A is going to 0 dBm all the time
  • #3452: Driver Antenna AR AT5080 and Schwarzbeck HFRA9150
  • #3451: Driver: Teseq CBA 1G-1000 and milmega AS0104-400/200
  • #3439: Starting level of a multiband test is -100 while the start level setting of the signal generator is -50 in the configuration
  • #3375: Error message from ESU8 in CE/RE-MB test "more points received than expected"
  • #3094: Using a measure and observation time of both 5 seconds is raising problems with the R&S ESU
  • #3017: ESU-40 driver issues in FFT mode
  • #2589: R&S ESU (GPIB controlled) and R&S ESU (LAN controlled) should be combined into a single driver
  • #2745: Problems with ESU 8 when doing Time Domain Scan
  • #2871: Determination of interference threshold does not work at BCI closed loop
  • #2958: R&S SME 03 AM 0% instead of off to prevent the relay from dying

RadiMation version 5.6.0

  • #420: Option to limit the power in a conducted immunity substitution test, based on the calibrated forward power
  • #421: Configurable device driver for reading out an AD-convertor
  • #954: Step frequency in RE test
  • #1302: EMI test with log. Frequency steps
  • #1741: PSA limit not the only one describing power limitation on forward power calibration
  • #1803: Device driver for AR 500W1000 is conflicting for different end-users
  • #1811: Switch matrix device driver for the HP 3488A
  • #2145: Amplifier is switch in POWER OFF after BCI test
  • #2450: Changing description 'PSA-Limit' to 'Power Limit' in BCI
  • #2538: Not possible to level on the current in CI substitution manual mode
  • #2699: During a 'Check' for a device, all the other controls should be disabled
  • #2774: Question to CE measurement (problem with accuracy of detected peak)
  • #2881: Driver: Advantest R3131A as powermeter
  • #2925: Driver for Yokogawa Oscilloscope DL1740
  • #2929: A small misspell in the CE test.
  • #2957: RadiSwitch 6 port does not have an option to not switch the relay
  • #3111: How to level on the current during BCI substitution tests?
  • #3178: 500W1000 is not switched to OPERATE in version 5.3.18
  • #3182: RadiMation sets Anritsu 2623B to wrong settings
  • #3185: Driver: SUNOL CONT94
  • #3231: 150A400 "needs" a reset command when leaving manual mode
  • #3248: Selecting square wave AM modulation does not change the waveform on the Agilent 83640B, and it doesn't raise an error
  • #3264: Speaker of the HP 8591E analyser is sometimes activated
  • #3318: files are getting bigger, customer can't open them anymore
  • #3320: wrong remeasured frequencies in Radiated Immunity (singleband)- Manual Mode
  • #3334: Peak not detected when zooming in Multiband Emisson graph
  • #3337: How is the Ramp in Mult. Im. configured?
  • #3338: Problems starting Cond. Im. Multiband
  • #3379: Final measurement with QP detector using a PMM 9030 receiver results in a software crash
  • #3391: Clean install crashes when opening device driver configuration window
  • #3392: clean install sets the configuration directory incorrectly to Radimationconfdvdr
  • #3399: HP8657 signal generator driver does not support 400 Hz AM.
  • #3405: Rs-232 support for the configurable switch matrix
  • #3406: signal generator sml03 sometimes is not responding to opc?
  • #3408: Driver FC03, turn table and antenna tower controller
  • #3413: Carad driver is reporting mcItestData is nothing
  • #3416: AM modulation indication on the HP 83630 is not activated
  • #3417: Using the ESU tracking generator as a signal generator for the attenuation measurement
  • #3422: PSA preselector need option to set the preselector off so that you can measure above the 1 GHz.
  • #3426: Driver: Agilent 87405C pre amplifier
  • #3428: Driver: HP 59307
  • #3426: Driver: ESV-Z1 VHF Current Probe
  • #3430: Driver: LISN PMM L3-64
  • #3431: Driver: ENI 603L and 411LA
  • #3432: Driver: Solar 9142-1N and 9719-1N
  • #3433: Driver: EATON 93686-8L and EM test HFK
  • #3437: LISN ESU User port
  • #3438: TDS220 is only available as an AD convertor not as an oscilloscope
  • #3448: Conducted Immunity Fixed Current with activated performance threshold is crashing
  • #3460: Format string does not work correctly with %lf and a double.