Line 8: |
Line 8: |
| !Expert | | !Expert |
| |- | | |- |
− | |General
| + | !General |
| | | | | |
| * Able to create a new EUT file | | * Able to create a new EUT file |
Line 23: |
Line 23: |
| | | | | |
| |- | | |- |
− | |[[Radiated Immunity]]
| + | ![[Radiated Immunity]] |
| | | | | |
| | | | | |
Line 31: |
Line 31: |
| | | | | |
| |- | | |- |
− | |[[Conducted Immunity]]
| + | ![[Conducted Immunity]] |
| | | | | |
| | | | | |
Line 39: |
Line 39: |
| | | | | |
| |- | | |- |
− | |[[Pulsed Immunity]]
| + | ![[Pulsed Immunity]] |
| | | | | |
| | | | | |
Line 45: |
Line 45: |
| | | | | |
| |- | | |- |
− | |[[Radiated Emission]]
| + | ![[Radiated Emission]] |
| | | | | |
| | | | | |
Line 52: |
Line 52: |
| | | | | |
| |- | | |- |
− | |[[Conducted Emission]]
| + | ![[Conducted Emission]] |
| | | | | |
| | | | | |
Line 59: |
Line 59: |
| | | | | |
| |- | | |- |
− | |[[Report Generator]]
| + | ![[Report Generator]] |
| | | | | |
| * Able to generate a report from an existing template | | * Able to generate a report from an existing template |
Line 71: |
Line 71: |
| * Able to create custom SQL report generator codes | | * Able to create custom SQL report generator codes |
| |- | | |- |
− | |Configuration / Installation
| + | !Configuration / Installation |
| | | | | |
| * Able to start a sequence | | * Able to start a sequence |
Line 80: |
Line 80: |
| * Able to create / modify a sequence | | * Able to create / modify a sequence |
| * Able to create and configure testsites | | * Able to create and configure testsites |
| + | * Able to add / modify test engineers |
| | | | | |
| * Able to install and configure {{RadiMation}} on a network | | * Able to install and configure {{RadiMation}} on a network |
Line 89: |
Line 90: |
| * Able to modify Advanced Options | | * Able to modify Advanced Options |
| |- | | |- |
− | | Measurement equipment
| + | !Measurement equipment |
| | | | | |
| | | | | |
Revision as of 11:54, 2 December 2014
To structure the different levels of experience with RadiMation, we created an experience level matrix:
|
Novice
|
Competent
|
Master
|
Expert
|
General
|
- Able to create a new EUT file
- Able to start an existing TSF
|
- Able to create / modify a TSF
- Able to specify Monitoring inputs
- Able to create / modify Correction files
- Able to retrieve customer information from another database
- Able to change / add information items
- Able to export graphs and data to other software programs
|
- Able to optimize the change order in Multiband tests
|
|
Radiated Immunity
|
|
- Able to perform a calibration
- Able to perform a 16 point UFA calculation
|
|
|
Conducted Immunity
|
|
- Able to perform a calibration
- Able to create / modify a TSF
|
|
|
Pulsed Immunity
|
|
|
|
|
Radiated Emission
|
|
- Able to create / modify limit lines
|
|
|
Conducted Emission
|
|
- Able to create / modify limit lines
|
|
|
Report Generator
|
- Able to generate a report from an existing template
|
- Able to create or modify report generator templates
- Able to use the Excel Exporter functionality
|
- Able to use sub-templates
- Able to use ||...|IncludeFile()|| codes
|
- Able to create custom SQL report generator codes
|
Configuration / Installation
|
- Able to start a sequence
- Able to check if a device is connected
|
- Able to install RadiMation on a PC
- Able to update device drivers
- Able to create / modify a sequence
- Able to create and configure testsites
- Able to add / modify test engineers
|
- Able to install and configure RadiMation® on a network
- Able to add actions to a testsite
- Able to configure a customer database interface
- Able to configure basic standards and product standards
|
- Able to configure default EUT Information Items
- Able to modify Advanced Options
|
Measurement equipment
|
|
- Able to add and configure device drivers for measurement equipment
- Aware of diffences between spectrum analyzer / scanning receiver / receiver
|
- Able to create NI-SPY files
- Able to optimize powermeter and field sensor monitoring settings
- Able to use configurable device drivers to control equipment
- Able to configure automatically controlled LISN's
- Able to configure switch matrixes
- Able to apply corrections to the measurement equipment
|
|
RadiMation® Free
|
- Able to connect to devices and perform measurements
|
- Able to perform ETSI EN 300328 burst measurements
|
|
|