Configurable AD Convertor: Difference between revisions
Jump to navigation
Jump to search
Line 35: | Line 35: | ||
== Readback example(s) == | == Readback example(s) == | ||
= | {| class="Regex example table" | ||
|- | |||
! Received information | |||
! Regex | |||
! RadiMation Readout | |||
! Note | |||
|- | |||
| U_L_N 325 | |||
| (-?[0-9.,Ee-]+) | |||
| 325 | |||
| Takes the first number. | |||
|- | |||
| I_L1;12.34 | |||
| ;(-?[0-9.,Ee-]+) | |||
| 12.34 | |||
| Takes the first number after ";". | |||
|- | |||
| THD_U_L1;;14,5 | |||
| ;;(-?[0-9.,Ee-]+) | |||
| 14.5 | |||
| Takes the first number after ";;". | |||
|- | |||
| AC_FREQ;Channel1;1.23E3 | |||
| ;*;(-?[0-9.,Ee-]+) | |||
| 1230 | |||
| Takes the first number after the appearance of a second ";". | |||
|} |
Revision as of 09:31, 6 October 2016
The Configurable AD Convertor device driver is a AD Converter which is supported by RadiMation®.
Reset | The reset code that needs to be send to device. When left blank no command will be send. |
Init | The Init code that needs to be send to device. When left blank no command will be send. |
Get Id | The code that needs to be send to device to get the identification back. A common used SCPI command is *IDN?. When left blank no command will be send. |
Trigger and Reading |
|
Trigger and Reading |
|
Readback example(s)[edit]
Received information | Regex | RadiMation Readout | Note |
---|---|---|---|
U_L_N 325 | (-?[0-9.,Ee-]+) | 325 | Takes the first number. |
I_L1;12.34 | ;(-?[0-9.,Ee-]+) | 12.34 | Takes the first number after ";". |
THD_U_L1;;14,5 | ;;(-?[0-9.,Ee-]+) | 14.5 | Takes the first number after ";;". |