The Configurable AD Convertor device driver is a AD Converter which is supported by RadiMation®.
Reset | The reset code that needs to be send to device. When left blank no command will be send. |
Init | The Init code that needs to be send to device. When left blank no command will be send. |
Get Id | The code that needs to be send to device to get the identification back. A common used SCPI command is *IDN?. When left blank no command will be send. |
Trigger and Reading |
|
Trigger and Reading |
|
Examples[edit]
Received information
|
Regex
|
RadiMation Readout
|
Note
|
---|---|---|---|
U_L_N 325 | (-?[0-9.,Ee-]+)
|
325
|
Takes the first number.
|
I_L1;12.34 | ;(-?[0-9.,Ee-]+)
|
12.34
|
Takes the first number after ";".
|
THD_U_L1;;14,5 | ;;(-?[0-9.,Ee-]+)
|
14.5
|
Takes the first number after ";;".
|
AC_FREQ;Channel1;1.23E3 | ;*;(-?[0-9.,Ee-]+)
|
1230
|
Takes the first number after the appearance of a second ";".
|
Read backs can always be tested trough the "Validate Expression tool" File:ValidateExpressionTool.jpg