During the measurement, all parameter such as {{ScreenElement|Max. e.i.r.p}}, {{ScreenElement|medium utilisation}}, {{ScreenElement|Duty cycle}}, {{ScreenElement|Min. Gap time}},{{ScreenElement|Max. Sequence time}} and {{ScreenElement|RMS}} are calculated and shown.  
During the measurement, the resulting measurement values such as {{ScreenElement|Max. e.i.r.p}}, {{ScreenElement|medium utilisation}}, {{ScreenElement|Duty cycle}}, {{ScreenElement|Min. Gap time}},{{ScreenElement|Max. Sequence time}} and {{ScreenElement|RMS}} are calculated and shown.  


{{ScreenElementDescriptionStart}}
{{ScreenElementDescriptionStart}}

Revision as of 16:34, 2 December 2014

Performing an ETSI EN300328 MIMO measurement

This application note explains how a MIMO measurement can be performed with RadiMation® Free as it is described in the ETSI EN300328.

It is assumed that device drivers for the used powermeters are already configured in the configuration of RadiMation®. Otherwise see Device driver configuration in Chapter 2 of the RadiMation® Manual.

Create a new EUT-file by selecting from the menu bar:

   Menu.svg File
      Menu.svg New
         Menu.svg EUT

Specify a filename for the new EUT-file and select OK. A new EUT-window will now be opened.

To start the Burst measurement select from the menu bar:

   Menu.svg Tests
      Menu.svg Radiated Emission
         Menu.svg Burst

SelectRadiatedEmissionBurstFromMenu.png

Press New to create a new TSF-file.

The Radiated Emission Burst TSF window will now be opened in which the burst test can be configured.

RadiatedEmissionBurstTSF.png

In this TSF window it is important to Add a powermeter, and to configure the measurement parameters.

The following settings are available and can be configured:

ScreenElementDescription.svg Powermeters Shows the list of currently selected powermeters that will be used during the measurement
ScreenElementDescription.svg Add Allows to add one or more power meters to your test.
ScreenElementDescription.svg Edit Shows the device driver configuration of the selected powermeter
ScreenElementDescription.svg Remove Removes the selected powermeter from the list of powermeters that will be used
ScreenElementDescription.svg Carrier Frequency The primary frequency that will be measured by the powermeters. This frequency is used to correct the measurement result of the powermeters.
ScreenElementDescription.svg Trigger level Specifies the power level for the trigger level of the powermeters. The powermeters will assume that a measurement sample is part of a burst if the measurement sample is above the specified Trigger level
ScreenElementDescription.svg Measurement time The total time for the measurement
ScreenElementDescription.svg Sample Rate The sample rate that should be used by the powermeters
ScreenElementDescription.svg Gap Time The Gap Time specifies the minimum time that the measurement samples should be below the Trigger level to designate that period of time as a gap in the transmission
ScreenElementDescription.svg Threshold Level The Threshold Level defines a dB difference to the maximum measured burst value, which is used to determine if a measured burst value is designated as a transmission. Any burst that has a maximum value that is more than Threshold Level below the maximum burst value during the complete Measure time will not be designated as a transmission.
ScreenElementDescription.svg Assembly Gain The gain of the antenna that is normally connected to an output of the EUT. This Assembly Gain is used to calculate the total e.i.r.p. power.
ScreenElementDescription.svg Beamforming Gain The gain of the additional benefit of the combining of the multiple antenna's of the EUT. This Beamforming Factor is used to calculate the total e.i.r.p. power.


The Gap Time, Threshold Level, Assembly Gain and Beamforming Gain are terms that are explained in the ETSI EN300328 standard.

Pressing Start Test will start the measurement with the selected power meters and the configured parameters. Enter a filename to save the TSF-file, so it can be used again in the future.

The measurement is then started and the results are shown in the Radiated Emission Burst Status window.

RadiatedEmissionBurstResult.png

During the measurement, the resulting measurement values such as Max. e.i.r.p, medium utilisation, Duty cycle, Min. Gap time,Max. Sequence time and RMS are calculated and shown.


ScreenElementDescription.svg Graph Shows the measurement result of the burst measurement. The individual measurement of each selected powermeter will be shown, and also the combined measurement result of all the graphs. It is possible to zoom-in on the measurement data to have more measurement details.
ScreenElementDescription.svg Measurement Values Shows some final resulting measurement values as it is required by the ETSI EN300328
ScreenElementDescription.svg Max. e.i.r.p. Shows the maximum effective isotropic radiated power of the last combined measurement data.
ScreenElementDescription.svg Medium Utilisation Shows the percentage of the medium utilisation of the last combined measurement data.
ScreenElementDescription.svg Duty Cycle Shows the percentage of the time that a transmission was active during the last combined measurement data. This is the total TxSequence time compared to the total TxGap time.
ScreenElementDescription.svg Min. Gap Time Shows the smallest period of time that was designated as a gap during the last combined measurement data.
ScreenElementDescription.svg Max. Sequence Time Shows the largest period of time that was designated as a transmission during the last combined measurement data.
ScreenElementDescription.svg RMS Shows the total RMS power of the complete last combined measurement data (including the gap and transmissions). This value should be the same as the power meter reading of True RMS powermeter.
ScreenElementDescription.svg Measurement Settings Contains more measurement parameters that can be changed.
ScreenElementDescription.svg Carrier Frequency The primary frequency that will be measured by the powermeters. This frequency is used to correct the measurement result of the powermeters.
ScreenElementDescription.svg Manual Selects the manual triggering mode, where a new measurement is only performed when the Trigger button is pressed.
ScreenElementDescription.svg Trigger Starts a new measurement of all the selected powermeters with the configured measurement settings. Also the combined measurement data will be recalculated and also the Measurement Values will be recalculated.
ScreenElementDescription.svg Auto Selects the auto triggering mode. A new measurement will be started using the interval that is specified at the Auto setting. Also the combined measurement data will be recalculated and also the Measurement Values will be recalculated.
ScreenElementDescription.svg Trigger level Specifies the power level for the trigger level of the powermeters. The powermeters will assume that a measurement sample is part of a burst if the measurement sample is above the specified Trigger level
ScreenElementDescription.svg Measure time The total time for the measurement
ScreenElementDescription.svg Sample Rate The sample rate that should be used by the powermeters
ScreenElementDescription.svg Gap Time The Gap Time specifies the minimum time that the measurement samples should be below the Trigger level to designate that period of time as a gap in the transmission
ScreenElementDescription.svg Threshold Level The Threshold Level defines a dB difference to the maximum measured burst value, which is used to determine if a measured burst value is designated as a transmission. Any burst that has a maximum value that is more than Threshold Level below the maximum burst value during the complete Measure time will not be designated as a transmission.
ScreenElementDescription.svg Assembly Gain The gain of the antenna that is normally connected to an output of the EUT. This Assembly Gain is used to calculate the total e.i.r.p. power.
ScreenElementDescription.svg Beamforming Gain The gain of the additional benefit of the combining of the multiple antenna's of the EUT. This Beamforming Factor is used to calculate the total e.i.r.p. power.
ScreenElementDescription.svg Powermeters Shows the list of currently selected powermeters that will be used during the measurement
ScreenElementDescription.svg Add Allows to add one or more power meters to your test.
ScreenElementDescription.svg Edit Shows the device driver configuration of the selected powermeter
ScreenElementDescription.svg Remove Removes the selected powermeter from the list of powermeters that will be used
ScreenElementDescription.svg Connected Shows the connection state with the selected powermeters. Also the connection with the powermeters can be disabled or re-activated by pressing the Connected button.


When the measurement is finished configuration parameters can be changed if desired, and a new measurement can be triggered by pressing the Trigger button.

The measurement results can be saved into the created EUT file by pressing the Close button, which will also close the measurement window.