Configurable AD Convertor
Jump to navigation
Jump to search
The Configurable AD Convertor device driver is a AD Converter which is supported by RadiMation®.
Initialisation and Check[edit]
Reset | The reset code that needs to be send to device. When left blank no command will be send. |
Init | The command that is send to initialize the configured device. When left blank no command will be send. |
Get Id | The command that is send to retrieve the ID of the device. This is used to check if the device is connected. A common used SCPI command is *IDN?. When left blank no command will be send. |
Channels[edit]
AD convertors can have multiple channels on which AD values could be read. For each AD channel, different commands can be set.
Trigger and Reading[edit]
- A trigger command can be specified to request a measurement from the device.
- A regular expression can be set to parse 1 numeric value from the returned message of the device. The parsed number will be used in RadiMation
Trigger and Readback |
The trigger and read back commands are used to receive the measured values into RadiMation
|
Trigger and Reading[edit]
Minimum and maximum value |
Minimum and maximum can be set to limit the measured value.
|
Readback example(s)[edit]
Received information
|
Regex
|
RadiMation Readout
|
Note
|
---|---|---|---|
U_L_N 325 | (-?[0-9.,Ee-]+)
|
325
|
Takes the first number.
|
I_L1;12.34 | ;(-?[0-9.,Ee-]+)
|
12.34
|
Takes the first number after ";".
|
THD_U_L1;;14,5 | ;;(-?[0-9.,Ee-]+)
|
14.5
|
Takes the first number after ";;".
|
AC_FREQ;Channel1;1.23E3 | ;*;(-?[0-9.,Ee-]+)
|
1230
|
Takes the first number after the appearance of a second ";".
|