Software protection key
A protection key (which we often call: Dongle) is used to prevent software piracy of RadiMation. The protection key is required to perform an EMC test, or to use the report generator
The black dongle[edit]
With the release of version 5.3 of RadiMation, all dongles have been replaced with new black dongles. This was necessary because version 5.3 of RadiMation is using an improved mechanism to determine the contens of the dongle. This improvement required that the programming of each dongle was replaced. Each dongle also has a keyhanger connected to it.
The dongle contains a label, that identifies the key as being a dongle for RadiMation. Also the identification of the key itself is included on this label, which starts with: 'SIH00133 ......'
The keyhanger contains a label with more specific information of the programmed dongle. This information consists of the identifier of the dongle, and all activated modules. Each activated module is represented by a two character code.
- RI: Radiated Immunity module
- CI: Conducted Immunity module
- PI: Pulsed Immunity module
- RE: Radiated Emission module
- CE: Conducted Emission module
- RG: Report Generator module
- EE: Excel Exporter module
- RC: RadiCal module
- AC: Amplifier Calibration module
- AD: Antenna Diagram module
We do not provide an utility that can be used to read out the configuration of the dongle.
The purple dongle[edit]
In the past (before version 5.3) several purple dongles have been shipped to RadiMation customers. These keys can still be in use at customers who do not have a service contract, or not yet have performed the upgrade. These dongles do not have a keyhanger and no labels. It is not possible to determine the configuration of activated modules that are programmed inside these purple dongles.
The identification number of these purple dongles however can be determined, by reading the numbers from the dongle. This purple dongle has the key value of SIH00133 0651/24
- Green circle: SIH00133
- Red circle: 0651
- Purple circle: /24
Dongle drivers[edit]
If the protection key is used, it is advisable to use the latest drivers for reading out the protection key. The latest drivers are included in the setup program of RadiMation. However some times it can be necessary to update the protection key drivers, because for example, older drivers can have problems on newer PC's.
Use the following steps to upgrade these drivers:
- Download this zip file
- Get all files from the zip file
- Close any running RadiMation instance
- Start the Setup.exe file
- Follow the instructions of the setup program
- Restart the PC
Note: | Administrator rights are needed to perform the upgrade |