Chapter 13
Report Generator[edit]
The Report Generator is a software module to automatically generate a test report from tests that are carried out by RadiMation®. Once RadiMation® had carried out a test, all collected test data is available to the RadiMation® report generator, and this data can be merged into a test report. Using the Report Generator module, a test engineer can save a huge amount of time. The Report Generator only needs a few minutes to generate a complete test report.
Test reports can be written in Microsoft Word, Microsoft Excel or Text format.
Generating a report[edit]
Open an EUT and press the Report button on the Reports tab of the EUT window. This button shows the screen in which the settings for the generation of the report can be selected.
To select a template file, select the folder button for the template. The red cross is for deleting the file selection, not the file itself. The magnifying glass is for viewing the template. If you want to print the report directly after it has been generated then check the check box for print report. If you want to edit the report then check the Edit report check box. By default all tests are included for generating a report. If you want to alter the selection press the Advanced Option button. An additional screen will be displayed like as shown above. All tests with the red checks in front will be included. Double clicking a test will alter the include/exclude selection. With the "Include All" button all tests will be included. With "Include None" all tests will be excluded from the report. "Invert Selection" will invert all the including/excluding. Selecting the "Generate" button will start the report generation process. The report will be finished in a few moments. The generation time varies between a couple of seconds for a text file to several minutes for an extensive report containing many tables and graphs in MS Word.
Template files and Report files[edit]
The report Generator uses two files to generate a report. These two files are the Template file and the Report file. The Template file is the complete Report containing keywords. The test Data is represented by unique keywords, which tell the report generator which data to insert at the position of the code. The Report Generator changes all codes into test data and thus creates the report. This Report file is the complete test report including all test data. The Template file is not altered. It is recommended to make this Template file read-only, so no one can accidentally delete or modify this file. The Template file must exist, the Report file will be created, if it doesn’t exist. The Template file and report file may not be the same file!
Keywords and Main Keywords[edit]
A template file contains one or more unique keywords. These keywords consist of a Main Keyword and a second Keyword. The codes are of the following type: ||Main keyword | second keyword|| The Main Keyword indicates the part of RadiMation® from which the data must be retrieved. The Keyword specifies the data to be merged into the report file. The Main Keyword can be:
- EUT
- "Configuration" - The name of a test specified in the list in the EUT Window
Every Main Keyword has a set of Keywords that can only be used in combination with the used Main Keyword.
For example:
The EUT Main Keyword can use the keyword "Serial Number", but the "Serial Number" keyword is not supported by the "Configuration" Main Keyword. A list of Keywords is given in the succeeding paragraphs of in this manual. The keywords must be spelled correctly, including spaces and other symbols. To separate multiple words, only one space is used. Keywords and Main keywords are not case sensitive. When a Keyword or Main Keyword is not recognised, or when there is no test data available for this Keyword or Main keyword, the code will not be altered. The test engineer will be given a message in the settings screen of the Report Generator. One failure will be added to the total amount of failures. If a template file is altered, or the test-name has changed, the test engineer should search a generated report for codes from the template file for he may have used codes that contain no data or are not recognised by the Report Generator.
Available Report Generator Codes for EUT's[edit]
The Main keyword for EUT data is "EUT". All data entered in the EUT Window in RadiMation® can be merged into a report file. All data can be merged as single lines of text or in tables. Tables are supported for Client data, Manufacturer data and Test site data. In addition, a table with all information can be merged.
Available Report Generator Keywords[edit]
As different tests use different equipment and perform different actions each test has its own set of keywords. In many cases tests share the same keywords although this will refer to different data as the combination of main keyword and secondary keyword will always result in a unique combination. Errors are easily located by searching the report for the characters "||". Once found these can be deleted, or changed into an existing code. If the Report Generator is executed once again, using the modified file as the template, the Report Generator will finish the report without errors.
EUT[edit]
Common[edit]
Keyword | Description |
---|---|
FILENAME | The filename of the EUT |
BRAND | The brand of the EUT specified in the EUT Window |
CONDITION RECEPTION | The condition of reception of the EUT specified in the EUT Window |
DATE RECEIPT | The date of reception of the EUT specified in the EUT Window |
DATE MEASURMENT | The date of measurment of the EUT specified in the EUT Window |
DIMENSIONS | The dimensions of the EUT specified in the EUT Window |
EMISSION STANDARD | The emission standard of the EUT specified in the EUT Window |
ENVIRONMENT | The environment of the EUT specified in the EUT Window |
IMMUNITY STANDARD | The immunity standard of the EUT specified in the EUT Window |
NAME | The name of the EUT specified in the EUT Window |
ORDER NUMBER | The order number of the EUT specified in the EUT Window |
PCB RELEASE | The PCB release of the EUT specified in the EUT Window |
PERIPHERAL EQUIPMENT | The peripheral equipment of the EUT specified in the EUT Window |
PLACE MEASURMENT | The place of measurment of the EUT specified in the EUT Window |
RADIMATION VERSION | The RadiMation® version |
RATED POWER | The rated power of the EUT specified in the EUT Window |
SERIAL NUMBER | The serial number of the EUT specified in the EUT Window |
SETUP TYPE | The test setup type of the EUT specified in the EUT Window |
SOFTWARE RELEASE | The software release of the EUT specified in the EUT Window |
TYPE NUMBER | The type number of the EUT specified in the EUT Window |
VOLTAGE SUPPLY | The voltage supply of the EUT specified in the EUT Window |
Client Address Information[edit]
Keyword | Description |
---|---|
CLIENT ADDRESS | The address of the client specified in the EUT Window |
CLIENT CAPACITY | The capacity of the client specified in the EUT Window |
CLIENT CITY | The city of the client specified in the EUT Window |
CLIENT COMPANY | The client name specified in the EUT Window |
CLIENT CONTACT PERSON | The contact person of the client specified in the EUT Window |
CLIENT COUNTRY | The country of the client specified in the EUT Window |
CLIENT EMAIL ADDRESS | The email address of the client specified in the EUT Window |
CLIENT FAX NUMBER | The fax number of the client specified in the EUT Window |
CLIENT STATE | The state of the client specified in the EUT Window |
CLIENT TELEPHONE NUMBER | The telephone number of the client specified in the EUT Window |
CLIENT ZIP CODE | The ZIP code of the client specified in the EUT Window |
Manufacturer Address Information[edit]
Keyword | Description |
---|---|
MANUFACTURER ADDRESS | The address of the manufacturer specified in the EUT Window |
MANUFACTURER CITY | The city of the manufacturer specified in the EUT Window |
MANUFACTURER COMPANY | The manufacturer name specified in the EUT Window |
MANUFACTURER CONTACT PERSON | The contact person of the manufacturer specified in the EUT Window |
MANUFACTURER COUNTRY | The country of the manufacturer specified in the EUT Window |
MANUFACTURER EMAIL ADDRESS | The email address of the manufacturer specified in the EUT Window |
MANUFACTURER FAX NUMBER | The fax number of the manufacturer specified in the EUT Window |
MANUFACTURER STATE | The state of the manufacturer specified in the EUT Window |
MANUFACTURER TELEPHONE NUMBER | The telephone number of the manufacturer specified in the EUT Window |
MANUFACTURER ZIP CODE | The ZIP code of the manufacturer specified in the EUT Window |
Test Site Address Information[edit]
Keyword | Description |
---|---|
TEST SITE ADDRESS | The address of the test site specified in the EUT Window |
TEST SITE CITY | The city of the test site specified in the EUT Window |
TEST SITE COMPANY | The test site name specified in the EUT Window |
TEST SITE CONTACT PERSON | The contact person of the test site specified in the EUT Window |
TEST SITE COUNTRY | The country of the test site specified in the EUT Window |
TEST SITE EMAIL ADDRESS | The email address of the test site specified in the EUT Window |
TEST SITE FAX NUMBER | The fax number of the test site specified in the EUT Window |
TEST SITE STATE | The state of the test site specified in the EUT Window |
TEST SITE TELEPHONE NUMBER | The telephone number of the test site specified in the EUT Window |
TEST SITE ZIP CODE | The ZIP code of the test site specified in the EUT Window |
Cable information[edit]
Keyword | Description |
---|---|
CABLE TABLE | A table with the cable information specified in the EUT Window |
CABLE X PORT TYPE | The port type of cable X in the EUT window ( X starting from 1) |
CABLE X CABLE TYPE | The cable type of cable X in the EUT window (X starting from 1) |
CABLE X CABLE LENGTH | The cable length of cable X in the EUT window (X starting from 1) |
CABLE X FIXING SHIELD | The fixing shield of cable X in the EUT window (X starting from 1) |
CABLE X LOAD AT PORT | The load at port of cable X in the EUT window (X starting from 1) |
Standards Information[edit]
Keyword Description PRODUCT STANDARD ... Specifications of the used Product Standard BASIC STANDARD ... Specifications of the used Basic Standard
Where ... is one of the following parameters:
Parameter | Description |
---|---|
DATEOFRELEASE | Release date of the standard |
DESCRIPTION | String containing official name / scope |
FILELOCATION | The location of the file associated with the standard |
LANGUAGE | The language in which the standard is described |
NOTE | Additional note to the standard |
OFFICIALNAME | The official name of the standard |
REFERRED STANDARDS | A string of referred standards, separated by a "," |
SCOPE | The scope of the standard |
STANDARDISATIONINSTITUTE | Description of Measurement equipment given by the user |
TABLE | Table of the used standards |
Configuration[edit]
Report Generator[edit]
Keyword | Description |
---|---|
COMNAME | Internal COM Name selected report generator |
DESCRIPTION | Selected report generator |
EXTENSION | Report generator extension |
CHECKEXTENSION | Report generator should check extension |
EDITOR | Report generator |
Directories[edit]
Keyword | Description |
---|---|
DEVICEDRIVERFILESDIRECTORY | CONFDVDR directory |
CALFILESDIRECTORY | CAL Files directory |
EUTFILESDIRECTORY | EUT Files directory |
TSFFILESDIRECTORY | TSF Files directory |
SEQFILESDIRECTORY | SEQ Files directory |
CORFILESDIRECTORY | COR Files directory |
DIRECTORIES | All directories |
Units[edit]
Keyword | Description |
---|---|
CURRENT | Current |
EMISSION AMPLITUDE | Emission |
FIELD | Electrical Field |
FREQUENCY | Frequency |
POWER | Power |
VOLTAGE | Voltage |
UNITS | All units |
General[edit]
Keyword | Description |
---|---|
CURRENTUSERNAME | Current username |
Radiated Immunity[edit]
Calibration[edit]
Keyword | Description |
---|---|
NUMBER OF EVENTS | The number of events that occur during a test |
EVENTS | Table of events which occur during a test |
Uniform Field Area Calculation[edit]
Keyword | Description |
---|---|
NUMBER OF EVENTS | The number of events that occur during a test |
TEST START TIME | The date and time at which the test is started |
TEST STOP TIME | The date and time at which the test is stopped |
TEST DATE | The date at which the test is performed |
TEST ENGINEER | The name of the test engineer |
TEST TIME | The time at which the test is performed |
TEST SITE NAME | The name of the test equipment list |
AVERAGE FIELD GRAPH | The graph representing the average field graph |
CALCULATED FIELD GRAPH | The graph representing the calculated field graph |
ERROR GRAPH | The graph representing the error graph |
FIELD GRAPH x | The graph representing the field graph of field strength sensor number [x], where x is a number between 1 and 8 |
FORWARD POWER GRAPH | The graph representing the forward power graph |
NET POWER GRAPH | The graph representing the net-power power graph |
POINT 16 ERROR GRAPH x | The graph representing the error graph of point number [x], where x is a number between 1 and 16 |
POINT 16 FIELD GRAPH x | The graph representing the field graph of point number [x], where x is a number between 1 and 16 |
POINT 16 POWER GRAPH x | The graph representing the power graph of point number [x], where x is a number between 1 and 16 |
REFLECTED POWER GRAPH | The graph representing the reflected power graph |
SIGNAL POWER GRAPH | The graph representing the signal power graph |
AMPLIFIER PROTECTION MODE | The Amplifier Protection mode: Signal Power, Forward Power and / or Reflected Power. |
AVERAGE FIELD | Which probes are selected for the calculation of the average field |
CURRENT MEASURED | Indication whether or not the current is measured: Yes / No |
DESCRIPTION | The description of the Test Setup File (TSF) |
DISTANCE | The distance between the antenna and the EUT in meters [m] |
DWELL TIME | The dwell time in seconds [s] |
FIELD TEST LEVEL | The field strength level in the unit selected by the user |
FORWARD POWER MEASURED | Indication whether or not the forward power is measured: Yes / No |
FREQUENCY CHANGE MODE | The method used to change frequency: Stress Method, Ramp Method, Constant Method or Fast Constant Method. |
Keyword | Description |
---|---|
HUMIDITY | Relative Humidity during the test in percentage relative Humidity [%RH] |
LOGARITHMIC STEP | The logarithmic frequency step in a percentage of the previous step |
LOGARITHMIC STEP FROM | The frequency the test was started from to calculate the proper logarithmic step size |
MAIN VOLTAGE | The mains voltage during the test in Volt [V] |
NET POWER MEASURED | Indication whether or not the net-power power is measured: Yes / No |
NOTE | Note or remark made during the test |
POLARIZATION | Antenna polarisation: Horizontal or Vertical |
PRESSURE | Air Pressure during the test in milliBar [mbar] |
RECALCULATE AVERAGE | Indication whether or not the average is recalculated: Yes / No |
REFLECTED POWER MEASURED | Indication whether or not the reflected power is measured: Yes / No |
START FREQUENCY | The start frequency in megahertz [MHz] |
STEP FREQUENCY | The linear frequency step in megahertz [MHz] |
STOP FREQUENCY | The stop frequency in megahertz [MHz] |
TEMPERATURE | Temperature during the test in degrees Celsius [oC] |
TSF FILENAME | The filename of the TSF file |
EQUIPMENT TABLE | A table containing all used equipment |
EVENTS | Table of events which occur during a test |
FIELD UNIT | The selected unit for field strength: [dBuV/m], [dBmV/m], [dBV/m], [uV/m], [mV/m] or [V/m] |
POWER UNIT | The selected unit for power: [dBuW], [dBm], [dBmW], [dBW], [uW], [mW] or [W] |
VOLTAGE UNIT | The selected unit for voltage: [dBuVrms], [dBmVrms], [dBVrms], [uVrms], [mVrms] or [Vrms] |
Equipment for Uniform Field Area calculation[edit]
The equipment keyword consists of two parts: the keyword followed by a parameter. For each keyword all parameters are valid.
Example: AMPLIFIER BRAND returns the brand name of the amplifier.
Keyword | Description |
---|---|
AMPLIFIER ... | Specifications of the used Amplifier |
ANTENNA ... | Specifications of the used Antenna |
COUPLER ... | Specifications of the used Coupler |
FIELD SENSOR x ... | Specifications of the used Field Sensor number [x], where x is a number between 1 and 8 |
FORWARD POWER METER ... | Specifications of the used Forward Power Meter |
REFLECTED POWER METER ... | Specifications of the used Reflected Power Meter |
SIGNAL GENERATOR ... | Specifications of the used Signal Generator |
Where ... is one of the following parameters:
Parameter | Description |
---|---|
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
Radiated Immunity Tests[edit]
Keyword | Description |
---|---|
"keyword or name of photo" | The name or keyword of the photo |
NUMBER OF EVENTS | The number of events that occur during a test |
TEST START TIME | The date and time at which the test is started |
TEST STOP TIME | The date and time at which the test is stopped |
TEST DATE | The date at which the test is performed |
TEST ENGINEER | The name of the test engineer |
TEST TIME | The time at which the test is performed |
TEST SITE NAME | The name of the test equipment list |
AD GRAPH x | The graph representing the A/D graph of channel number [x], where x is a number between 1 and 8 |
AVERAGE FIELD GRAPH | The graph representing the average field graph |
CALCULATED FIELD GRAPH (1) | The graph representing the calculated field graph |
CURRENT GRAPH | The graph representing the current graph |
FIELD GRAPH x | The graph representing the field graph of field strength sensor number [x], where x is a number between 1 and 8 |
FORWARD POWER GRAPH | The graph representing the forward power graph |
NET POWER GRAPH | The graph representing the net-power power graph |
REFLECTED POWER GRAPH | The graph representing the reflected power graph |
SIGNAL POWER GRAPH | The graph representing the signal power graph |
AMPLIFIER PROTECTION MODE | The Amplifier Protection mode: Signal Power, Forward Power and or Reflected Power. |
AVERAGE FIELD | Which probes are selected for the calculation of the average field |
CALCULATED FIELD MEASURED(1) | Indication whether or not the calculated power is measured: Yes / No |
CALIBRATION FILE (1) | The name of the calibration file used for the test |
CALIBRATION METHOD | The calibration method used: Signal Generator Level, Forward Power or Net-Power |
CURRENT LIMIT | The Current limit in Ampere [A] |
CURRENT MEASURED | Indication whether or not the current is measured: Yes / No |
CURRENT UNIT | The selected current unit: [dBuA],[dBmA], [dBA], [uA], [mA] or [A] |
DESCRIPTION | The description of the Test Setup File (TSF) |
DISTANCE | The distance between the antenna and the EUT in meters [m] |
DWELL TIME | The dwell time in seconds [s] |
FIELD TEST LEVEL (2) | The field strength level in the unit selected by the user |
FORWARD POWER MEASURED | Indication whether or not the forward power is measured: Yes / No |
FREQUENCY CHANGE MODE | The method used to change frequency: Stress Method, Ramp Method, Constant Method or Fast Constant Method. |
HUMIDITY | Relative Humidity during the test in percentage relative Humidity [%RH] |
LOGARITHMIC STEP | The logarithmic frequency step in a percentage of the previous step |
LOGARITHMIC STEP FROM | The frequency the test was started from to calculate the proper logarithmic step size |
MAIN VOLTAGE | The mains voltage during the test in Volt [V] |
Keyword | Description |
---|---|
MODULATION | The type of modulation: none, Internal AM, External AM or Pulse |
MODULATION CONSERVATION | Indication whether peak conservation is used: Power, Voltage, none |
MODULATION DEPTH | Modulation depth in percentage of the carrier [%] |
MODULATION DUTY CYCLE | The duty cycle of the pulse modulation as a percentage [%] |
MODULATION FREQUENCY | The modulation frequency in Hertz [Hz] |
MODULATION SIGNAL | The type of modulation signal: Sine Wave or Square Wave |
NET POWER MEASURED | Indication whether or not the net-power power is measured: Yes / No |
NOTE | Note or remark made during the test |
POLARIZATION | Antenna polarisation: Horizontal or Vertical |
PRESSURE | Air Pressure during the test in milliBar [mbar] |
REFLECTED POWER MEASURED | Indication whether or not the reflected power is measured: Yes / No |
START FREQUENCY | The start frequency in megahertz [MHz] |
STEP FREQUENCY | The linear frequency step in megahertz [MHz] |
STOP FREQUENCY | The stop frequency in megahertz [MHz] |
TAKE START PICTURE | Indication whether or not to take a photo at the start of the test: Yes/No |
TEMPERATURE | Temperature during the test in degrees Celsius [oC] |
TSF FILENAME | The filename of the TSF file |
USE CURRENT LIMIT | Is the current limit used: Yes / No |
EQUIPMENT TABLE | A table containing all used equipment |
EVENTS | Table of events which occur during a test |
MANUAL MODE | Table containing the information collected during a manual mode session |
FIELD UNIT | The selected unit for field strength: [dBuV/m], [dBmV/m], [dBV/m], [uV/m], [mV/m] or [V/m] |
POWER UNIT | The selected unit for power: [dBuW], [dBm], [dBmW], [dBW], [uW], [mW] or [W] |
VOLTAGE UNIT | The selected unit for voltage: [dBuVrms], [dBmVrms], [dBVrms], [uVrms], [mVrms] or [Vrms] |
1) Substitution Method only 2) Substitution Method and Fixed Field Method only
Equipment for Radiated Immunity Tests[edit]
The equipment keyword consists of two parts: the keyword followed by a parameter. For each keyword all parameters are valid.
Example: AMPLIFIER SERIAL NUMBER returns the serial number of the amplifier.
Keyword | Description |
---|---|
AD CONVERTOR ... | Specifications of the used A/D Converter |
AMPLIFIER ... | Specifications of the used Amplifier |
ANTENNA ... | Specifications of the used Antenna |
CABLE x ... | Specifications of the used Cable number [x], where x is a number between 1 to 8 |
COUPLER ... | Specifications of the used Coupler |
CURRENT SENSOR ... | Specifications of the used Current Sensor |
FIELD SENSOR x ... | Specifications of the used Field Sensor number [x], where x is a number between 1 and 8 |
FORWARD POWER METER ... | Specifications of the used Forward Power Meter |
REFLECTED POWER METER ... | Specifications of the used Reflected Power Meter |
SENSOR POWER METER ... | Specifications of the used Sensor Power Meter |
SIGNAL GENERATOR ... | Specifications of the used Signal Generator |
Where ... is one of the following parameters:
Parameter | Description |
---|---|
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
Conducted Immunity[edit]
Calibration[edit]
Keyword | Description |
---|---|
NUMBER OF EVENTS | The number of events that occur during a test |
TEST START TIME | The date and time at which the test is started |
TEST STOP TIME | The date and time at which the test is stopped |
TEST DATE | The date at which the test is performed |
TEST ENGINEER | The name of the test engineer |
TEST TIME | The time at which the test is performed |
TEST SITE NAME | The name of the test equipment list |
AMPLIFIER PROTECTION MODE | The Amplifier Protection mode: Signal Power, Forward Power and / or Reflected Power. |
CALIBRATION METHOD | The calibration method used: Signal Generator Level, Forward Power or Net-Power |
CURRENT MEASURED | Indication whether or not the current is measured: Yes / No |
CURRENT TEST LEVEL | The current test level in Ampere [A] |
CURRENT UNIT | The selected current unit: [dBuA], [dBmA], [dBA], [uA], [mA] or [A] |
DESCRIPTION | The description of the Test Setup File (TSF) |
DISTANCE | The distance between the antenna and the EUT in meters [m] |
DWELL TIME | The dwell time in seconds [s] |
FORWARD POWER MEASURED | Indication whether or not the forward power is measured: Yes / No |
FREQUENCY CHANGE MODE | The method used to change frequency: Stress Method, Ramp Method, Constant Method or Fast Constant Method. |
HUMIDITY | Relative Humidity during the test in percentage rel. Humidity [%RH] |
LOGARITHMIC STEP | The logarithmic frequency step in a percentage of the previous step |
LOGARITHMIC STEP FROM | The frequency the test was started from to calculate the proper logarithmic step size |
MAIN VOLTAGE | The mains voltage during the test in Volt [V] |
NET POWER MEASURED | Indication whether or not the net-power power is measured: Yes / No |
NOTE | Note or remark made during the test |
POLARIZATION | Antenna polarisation: Horizontal or Vertical |
PRESSURE | Air Pressure during the test in milliBar [mbar] |
REFLECTED POWER MEASURED | Indication whether or not the reflected power is measured: Yes / No |
START FREQUENCY | The start frequency in megahertz [MHz] |
STEP FREQUENCY | The linear frequency step in megahertz [MHz] |
STOP FREQUENCY | The stop frequency in megahertz [MHz] |
TEMPERATURE | Temperature during the test in degrees Celsius [oC] |
TSF FILENAME | The filename of the TSF file |
USE CURRENT TEST LEVEL | Indication the current test level is used: Yes / No |
USE VOLTAGE TEST LEVEL | Indication the voltage test level is used: Yes / No |
VOLTAGE TEST LEVEL | The voltage test level in the unit selected by the user |
EQUIPMENT TABLE | A table containing all used equipment |
EVENTS | Table of events which occur during a test |
POWER UNIT | The selected unit for power: [dBuW], [dBm], [dBmW], [dBW], [uW], [mW] or [W] |
VOLTAGE UNIT | The selected unit for voltage: [dBuVrms], [dBmVrms], [dBVrms], [uVrms], [mVrms] or [Vrms] |
Equipment for Calibration[edit]
The equipment keyword consists of two parts: the keyword followed by a parameter. For each keyword all parameters are valid.
Example: COUPLER TYPE returns the type of the coupler.
Keyword | Description |
---|---|
AMPLIFIER ... | Specifications of the used Amplifier |
ANTENNA ... | Specifications of the used Antenna |
CABLE x ... | Specifications of the used Cable number [x], where x is a number between 1 to 8 |
CLAMP ... | Specifications of the used Clamp |
CLAMP RESISTANCE | The resistance in Ohm (Ω) of the clamp |
COUPLER ... | Specifications of the used Coupler |
CURRENT SENSOR ... | Specifications of the used Current Sensor |
FORWARD POWER METER ... | Specifications of the used Forward Power Meter |
JIG ... | Specifications of the used Calibration Jig |
REFLECTED POWER METER ... | Specifications of the used Reflected Power Meter |
SENSOR POWER METER ... | Specifications of the used Sensor Power Meter |
SIGNAL GENERATOR ... | Specifications of the used Signal Generator |
Where ... is one of the following parameters:
Parameter | Description |
---|---|
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
Conducted Immunity Tests[edit]
Keyword | Description |
---|---|
"keyword or name of photo" | The name or keyword of the photo |
NUMBER OF EVENTS | The number of events that occur during a test |
TEST START TIME | The date and time at which the test is started |
TEST STOP TIME | The date and time at which the test is stopped |
TEST DATE | The date at which the test is performed |
TEST ENGINEER | The name of the test engineer |
TEST TIME | The time at which the test is performed |
TEST SITE NAME | The name of the test equipment list |
AD GRAPH x | The graph representing the A/D graph of channel number [x], where x is a number between 1 and 8 |
CALCULATED CURRENT GRAPH (1) | The graph representing the current graph |
CALCULATED VOLTAGE GRAPH (1) | The graph representing the calculated voltage graph |
CURRENT GRAPH | The graph representing the current graph |
FIELD GRAPH x | The graph representing the field graph of field strength sensor number [x], where x is a number between 1 and 8 |
FORWARD POWER GRAPH | The graph representing the forward power graph |
NET POWER GRAPH | The graph representing the net-power power graph |
REFLECTED POWER GRAPH | The graph representing the reflected power graph |
SIGNAL POWER GRAPH | The graph representing the signal power graph |
VOLTAGE GRAPH | The graph representing the voltage graph |
CALIBRATED POWER GRAPH | The graph representing the calibrated power limitation graph |
CALIBRATED POWER LIMIT GRAPH | The graph representing the calibrated power limitation graph |
AMPLIFIER PROTECTION MODE | The Amplifier Protection mode: Signal Power, Forward Power and / or Reflected Power. |
CALIBRATION FILE (1) | The name of the calibration file used for the test |
CALIBRATION METHOD | The calibration method used: Signal Generator Level, Forward Power or Net-Power |
CURRENT LIMIT | The Current limit in Ampere [A] |
CURRENT MEASURED | Indication whether or not the current is measured: Yes / No |
CURRENT TEST LEVEL | The current test level in Ampere [A] |
CURRENT UNIT | The selected current unit: [dBuA],[dBmA], [dBA], [uA], [mA] or [A] |
DESCRIPTION | The description of the Test Setup File (TSF) |
DISTANCE | The distance between the antenna and the EUT in meters [m] |
DWELL TIME | The dwell time in seconds [s] |
FORWARD POWER MEASURED | Indication whether or not the forward power is measured: Yes / No |
FREQUENCY CHANGE MODE | The method used to change frequency: Stress Method, Ramp Method, Constant Method or Fast Constant Method. |
HUMIDITY | Relative Humidity during the test in percentage relative Humidity [%RH] |
LOGARITHMIC STEP | The logarithmic frequency step in a percentage of the previous step |
LOGARITHMIC STEP FROM | The frequency the test was started from to calculate the proper logarithmic step size |
MAIN VOLTAGE | The mains voltage during the test in Volt [V] |
Keyword | Description |
---|---|
MODULATION | The type of modulation: none, Internal AM, External AM or Pulse |
MODULATION CONSERVATION | Indication whether peak conservation is used: Power, Voltage, none |
MODULATION DEPTH | Modulation depth in percentage of the carrier [%] |
MODULATION DUTY CYCLE | The duty cycle of the pulse modulation as a percentage [%] |
MODULATION FREQUENCY | The modulation frequency in Hertz [Hz] |
MODULATION SIGNAL | The type of modulation signal: Sine Wave or Square Wave |
NET POWER MEASURED | Indication whether or not the net-power power is measured: Yes / No |
NOTE | Note or remark made during the test |
POLARIZATION | Antenna polarisation: Horizontal or Vertical |
PRESSURE | Air Pressure during the test in milliBar [mbar] |
REFLECTED POWER MEASURED | Indication whether or not the reflected power is measured: Yes / No |
START FREQUENCY | The start frequency in megahertz [MHz] |
STEP FREQUENCY | The linear frequency step in megahertz [MHz] |
STOP FREQUENCY | The stop frequency in megahertz [MHz] |
TAKE START PICTURE | Indication whether or not a photo is taken at the start of the test: Yes/No |
TEMPERATURE | Temperature during the test in degrees Celsius [oC] |
TSF FILENAME | The filename of the TSF file |
USE CURRENT LIMIT | Is the current limit used: Yes / No |
USE CURRENT TEST LEVEL (2) | Indication the current test level is used: Yes / No |
USE VOLTAGE TEST LEVEL (6) | Indication the voltage test level is used: Yes / No |
VOLTAGE TEST LEVEL (6) | The voltage test level in the unit selected by the user |
EQUIPMENT TABLE | A table containing all used equipment |
EVENTS | Table of events which occur during a test |
MANUAL MODE | Table containing the information collected during a manual mode session |
POWER UNIT | The selected unit for power: [dBuW], [dBm], [dBmW], [dBW], [uW], [mW] or [W] |
VOLTAGE UNIT | The selected unit for voltage: [dBuVrms], [dBmVrms], [dBVrms], [uVrms], [mVrms] or [Vrms] |
POWER TEST LEVEL (3) | The power test level in the unit selected by the user |
STEP DOWN (4) | The number of dB's the test level is stepped down during a minimum performance test |
TOLERANCE (5) | The maximum allowable tolerance of the test-level |
1) Fixed Generator method and Minimum Performance Level Method Excluded
2) Substitution method and Fixed Current Method only
3) Fixed Generator level method only
4) Minimum Performance test method only
5) Fixed Current method and Minimum Performance test method only
6) Substitution method only
Equipment for Conducted Immunity Tests[edit]
The equipment keyword consists of two parts: the keyword followed by a parameter. For each keyword all parameters are valid.
Example: ANTENNA DESCRIPTION returns the description of the antenna.
Keyword | Description |
---|---|
AD CONVERTOR ... | Specifications of the used A/D Converter |
AMPLIFIER ... | Specifications of the used Amplifier |
ANTENNA ... | Specifications of the used Antenna |
CABLE x ... | Specifications of the used Cable number [x], where x is a number between 1 to 8 |
CLAMP ... | Specifications of the used Clamp |
CLAMP RESISTANCE | The resistance in Ohm (Ω) of the clamp |
COUPLER ... | Specifications of the used Coupler |
CURRENT SENSOR ... | Specifications of the used Current Sensor |
FORWARD POWER METER ... | Specifications of the used Forward Power Meter |
REFLECTED POWER METER ... | Specifications of the used Reflected Power Meter |
SENSOR POWER METER ... | Specifications of the used Sensor Power Meter |
SIGNAL GENERATOR ... | Specifications of the used Signal Generator |
Where ... is one of the following parameters:
Parameter | Description |
---|---|
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
Pulsed Immunity[edit]
ESD Test[edit]
Keyword | Description |
---|---|
NEG AIR MEASURED POINT x | Indication a Negative Air Discharge is performed at point number [x]: Yes / No |
NEG AIR RESULT POINT x | Results of Negative Air Discharge at point number [x]: pass or fail |
NEG CONTACT MEASURED POINT x | Indication a Negative Contact Discharge is performed at point number [x]: Yes / No |
NEG CONTACT RESULT POINT x | Results of Negative Contact Discharge at point number [x]: pass or fail |
NUMBER OF EVENTS | The number of events that occur during a test |
POS AIR MEASURED POINT x | Indication a Positive Air Discharge is performed at point number [x]: Yes / No |
POS AIR RESULT POINT x | Results of Positive Air Discharge at point number [x]: pass or fail |
POS CONTACT MEASURED POINT x | Indication a Positive Contact Discharge is performed at point number [x]: Yes / No |
POS CONTACT RESULT POINT x | Results of Positive Contact Discharge at point number [x]: pass or fail |
TEST START TIME | The time at which the test is stopped |
TEST STOP TIME | The time at which the test is started |
TEST SITE NAME | The name of the test equipment list |
AMPLITUDE POINT x | Amplitude of pulse performed at point number [x] in [V] |
CONFIGURATION TIME | The date and time when the TSF file is saved |
DESCRIPTION | Description of the Test Setup File (TSF) |
DISCHARGE INTERVAL | The interval of the discharge in seconds. |
HUMIDITY | Relative Humidity during the test in percentage relative Humidity [%RH] |
MAIN VOLTAGE | Mains Voltage during the test in Volt [V] |
NEG AIR LEVEL POINT x | Level of the Negative Air Discharge at point number [x] in [V] |
NEG CONTACT LEVEL POINT x | Level of the Negative Contact Discharge at point number [x] in [V] |
NOTE | Note or remark made during the test |
NOTE POINT x | Note or remark for point number [x] |
NUMBER OF DISCHARGES | The number of discharges |
PERFORMANCE CRITERIA CUSTOMER | The performance criteria according to the customer |
PERFORMANCE CRITERIA PRODUCT STANDARD | The performance criteria according to the product standard |
POS AIR LEVEL POINT x | Level of the Positive Air Discharge at point number [x] in [V] |
POS CONTACT LEVEL POINT x | Level of the Positive Contact Discharge at point number [x] in [V] |
PRESSURE | Air Pressure during the test in MilliBar [mbar] |
TDURATION POINT x | Duration of pulse at point number [x] in milliseconds [ms] |
TEMPERATURE | Temperature during the test in degrees Celsius [oC] |
TEST ENGINEER | The name of the test engineer |
TESTPOINT DESCRIPTION POINT nr | Position at EUT where discharge was applied |
TRISE POINT x | Rise time of pulse at point number [x] in milliseconds [ms] |
EQUIPMENT TABLE | A table containing all used equipment |
EVENTS | Table of events which occur during a test |
Equipment for ESD Tests[edit]
The equipment keyword consists of two parts: the keyword followed by a parameter. For each keyword all parameters are valid.
Example: ESDGUN BRAND returns the brand name of the ESD gun.
Keyword | Description |
---|---|
ESDGUN ... | Specifications of the used ESD Gun |
Where ... is one of the following parameters:
Parameter | Description |
---|---|
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
EFT Test[edit]
Keyword | Description |
---|---|
(L1-L2)/PE RESULT | Results on (L1-L2)/PE: Pass or Fail |
CAPCLAMP RESULT | Results on Capacitive Clamp: Pass or Fail |
L1 RESULT | Results on L1: Pass or Fail |
L1/L2 RESULT | Results on L1/L2: Pass or Fail |
L1/PE RESULT | Results on L1/PE: Pass or Fail |
L2 RESULT | Results on L2: Pass or Fail |
L2/PE RESULT | Results on L2/PE: Pass or Fail |
NUMBER OF EVENTS | The number of events that occur during a test |
PE RESULT | Results on PE (Protective Earth): Pass or Fail |
TEST START TIME | The time at which the test is stopped |
TEST STOP TIME | The time at which the test is started |
TEST SITE NAME | The name of the test equipment list |
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
(L1-L2)/PE MEASURED | (L1-L2)/PE Measured: Yes / No |
AMPLITUDE | Amplitude of burst in Volt [V] |
CAPCLAMP MEASURED | Capacitive Clamp Measured: Yes / No |
CONFIGURATION TIME | The date and time when the TSF file is saved |
DESCRIPTION | Description of the Test Setup File (TSF) |
DURATION | Duration of test in milliseconds [ms] |
FREQUENCY | Frequency of burst in Hertz [Hz] |
HUMIDITY | Relative Humidity during the test in percentage relative Humidity [%RH] |
L1 MEASURED | L1 Measured: Yes / No |
L1/L2 MEASURED | L1/L2 Measured: Yes / No |
L1/PE MEASURED | L1/PE Measured: Yes / No |
L2 MEASURED | L2 Measured: Yes / No |
L2/PE MEASURED | L2/PE Measured: Yes / No |
MAIN VOLTAGE | Mains Voltage during the test in Volt [V] |
Keyword | Description |
---|---|
NOTE | Note or remark made during the test |
NOTE (L1-L2)/PE | Notes or remarks for (L1-L2)/PE |
NOTE CAPCLAMP | Notes or remarks for Capacitive Clamp |
NOTE L1 | Notes or remarks for L1 |
NOTE L1/L2 | Notes or remarks for L1/L2 |
NOTE L1/PE | Notes or remarks for L1/PE |
NOTE L2 | Notes or remarks for L2 |
NOTE L2/PE | Notes or remarks for L2/PE |
NOTE PE | Notes or remarks for PE |
PE MEASURED | PE Measured: Yes / No |
PRESSURE | Air Pressure during the test in milliBar [mbar] |
TBURST | Duration of burst in milliseconds [ms] |
TEMPERATURE | Temperature during the test in degrees Celsius [oC] |
TEST ENGINEER | The name of the test engineer |
TPERIOD | Duration of period in milliseconds [ms] |
EQUIPMENT TABLE | A table containing all used equipment |
EVENTS | Table of events which occur during a test |
For every possible line the following items are available:
Keyword | Description |
---|---|
MEASURED | If the line was measured |
RESULT | The result on this line |
AMPLITUDE | The amplitude on this line |
NOTE | The note that is related to this line |
So for example code ||<testname>|L1 / L2 RESULT|| is valid.
Equipment for EFT Tests[edit]
The equipment keyword consists of two parts: the keyword followed by a parameter. For each keyword all parameters are valid.
Example: EFTGENERATOR TYPE returns the type of the EFT generator.
Keyword | Description |
---|---|
EFTGENERATOR ... | Specifications of the used EFT Generator |
Where ... is one of the following parameters:
Parameter | Description |
---|---|
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
Surge Test[edit]
Keyword | Description |
---|---|
(L1-L2)/PE MEASURED | (L1-L2)/PE measured: Yes / No |
(L1-L2)/PE RESULT | Results of Surge Test at (L1-L2)/PE: pass or fail |
L1/L2 MEASURED | Indication whether or not L1/L2 is measured: Yes / No |
L1/L2 RESULT | Results of Surge Test at L1/L2: pass or fail |
L1/PE MEASURED | Indication whether or not L1/PE is measured: Yes / No |
L1/PE RESULT | Results of Surge Test at L1/PE: pass or fail |
L2/PE MEASURED | Indication whether or not L2/PE is measured: Yes / No |
L2/PE RESULT | Results of Surge Test at L2/PE: pass or fail |
NUMBER OF EVENTS | The number of events that occur during a test |
TEST START TIME | The time at which the test is stopped |
TEST STOP TIME | The time at which the test is started |
TEST SITE NAME | The name of the test equipment list |
CINTSETTINGS (L1-L2)/PE | Internal Capacitance for (L1-L2)/PE |
CINTSETTINGS L1/L2 | Internal Capacitance for L1/L2 |
CINTSETTINGS L1/PE | Internal Capacitance for L1/PE |
CINTSETTINGS L2/PE | Internal Capacitance for L2/PE |
CONFIGURATION TIME | The date and time when the TSF file is saved |
DESCRIPTION | Description of the Test Setup File (TSF) |
HUMIDITY | Relative Humidity during the test in percentage relative Humidity [%RH] |
MAIN VOLTAGE | Mains Voltage during the test in Volt [V] |
NOTE | Note or remark made during the test |
NOTE (L1-L2)/PE | Note or remark for Surge Test at (L1-L2)/PE |
NOTE L1/L2 | Note or remark for Surge Test at L1/L2 |
NOTE L1/PE | Note or remark for Surge Test at L1/PE |
NOTE L2/PE | Note or remark for Surge Test at L2/PE |
PHASE (L1-L2)/PE | Phase angle between L1 - L2 and PE in degrees: 0, 90, 270, random |
PHASE L1/L2 | Phase angle between L1 and L2 in degrees: 0, 90, 270, random |
PHASE L1/PE | Phase angle between L1 and PE in degrees: 0, 90, 270, random |
PHASE L2/PE | Phase angle between L2 and PE in degrees: 0, 90, 270, random |
POLARISATION OF (L1-L2)/PE TESTLEVEL | Polarisation of test voltage at (L1-L2)/PE: Positive, Negative or both |
POLARISATION OF L1/L2 TESTLEVEL | Polarisation of test voltage at L1/L2: Positive, Negative or both |
POLARISATION OF L1/PE TESTLEVEL | Polarisation of test voltage at L1/PE: Positive, Negative or both |
POLARISATION OF L2/PE TESTLEVEL | Polarisation of test voltage at L2/PE: Positive, Negative or both |
PRESSURE | Air Pressure during the test in milliBar [mbar] |
RINTSETTINGS (L1-L2)/PE | Internal Resistance for (L1-L2)/PE |
RINTSETTINGS L1/L2 | Internal Resistance for L1/L2 |
RINTSETTINGS L1/PE | Internal Resistance for L1/PE |
RINTSETTINGS L2/PE | Internal Resistance for L2/PE |
TEMPERATURE | Temperature during the test in degrees Celsius [oC] |
TEST ENGINEER | The name of the test engineer |
Keyword | Description |
---|---|
TESTLEVEL (L1-L2)/PE | Test level at (L1-L2)/PE in kilo Volt [kV] |
TESTLEVEL L1/L2 | Test level at L1/L2 in kilo Volt [kV] |
TESTLEVEL L1/PE | Test level at L1/PE in kilo Volt [kV] |
TESTLEVEL L2/PE | Test level at L2/PE in kilo Volt [kV] |
EQUIPMENT TABLE | A table containing all used equipment |
EVENTS | Table of events which occur during a test |
For every available line the following codes can be applied:
Keyword | Description |
---|---|
MEASURED | If the selected line was measured |
RESULT | The result of the measurement |
POSITIVE TEST LEVEL | The positive test level(Yes / No) |
NEGATIVE TEST LEVEL | The negative testlevel(Yes / No) |
CI | The capacity used for this line configuration |
RI | The resistance used for this line configuration |
Test Level | The test level used for this line configuration |
Note | The note that applies to this line configuration |
PHASE 0 | Phase 0 measured (Yes / No) |
PHASE 90 | Phase 90 measured (Yes / No) |
PHASE 270 | Phase 270 measured (Yes / No) |
PHASE RANDOM | Phase random measured (Yes / No) |
Equipment for Surge Tests[edit]
The equipment keyword consists of two parts: the keyword followed by a parameter. For each keyword all parameters are valid.
Example: SURGEGENERATOR ID returns the internal ID of the Surge generator.
Keyword | Description |
---|---|
SURGEGENERATOR ... | Specifications of the used Surge Generator |
Where ... is one of the following parameters:
Parameter | Description |
---|---|
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
Radiated Emission[edit]
Note: | The pass/fail criteria, shown in the tables of the report generator do not take the measure uncertainty of the test setup into account. |
Radiated Emission Tests[edit]
Keyword | Description |
---|---|
"keyword or name of photo" | The name or keyword of the photo |
NUMBER OF EVENTS | The number of events that occur during a test |
PEAK DETECTION COUNT | The number of detected peaks |
TEST START TIME | The time at which the test is stopped |
TEST STOP TIME | The time at which the test is started |
MAX HOLD GRAPH | The max hold graph of the all the traces |
MAX HOLD PEAKS GRAPH | The max hold graph of all the traces and markers |
MAX PEAK GRAPH | The max hold graph of the Peak trace |
MAX AVERAGE GRAPH | The max hold graph of the Average trace |
MAX QUASI PEAK GRAPH | The max hold graph of the Quasi Peak trace |
MAX RMS GRAPH | The max hold graph of the RMS trace |
ANGLE STEPS | The number of steps between the start position and the stop position |
ATTENUATOR | The attenuation of the attenuator in dB |
ATTENUATOR MODE | The Attenuator Mode: Auto, Coupled or Manual |
AVERAGE DETECTOR | Indication whether or not the Average detector is measured: Yes / No |
AVERAGE MEASURE TIME | The measurement time of the average peak detector in seconds [s] |
AVERAGE OBSERVATION TIME | The observation time per average peak in seconds [s] |
AVERAGE TRACE | Indication whether or not the Average trace is measured: Yes / No |
BELOW LIMITLINE OFFSET | The level of peaks to detect in dB below the limit line |
CONFIGURATION TIME | The date and time when the TSF file is saved |
CURRENT UNIT | The selected unit for current: [dBuA], [dBmA], [dBA], [uA], [mA] or [A] |
DB/DIV | N/A |
DB/DIV MODE | N/A |
DESCRIPTION | Description of the Test Setup File (TSF) |
DISTANCE | The distance between the antenna and the EUT in meters [m] |
EMISSION OPTIMIZING METHOD | N/A |
HEIGHT STEPS | The number of steps between the minimum height and the maximum height |
HIGHEST HEIGHT | The maximum height of the antenna tower in meters [m] |
HUMIDITY | Relative Humidity during the test in percentage relative Humidity [%RH] |
INTERNAL PREAMPLIFIER | The amplification of the internal pre amplifier in [dB] |
INTERNAL PREAMPLIFIER MODE | The Internal Pre Amplifier Mode: Auto, Coupled or Manual |
LOWEST HEIGHT | The minimum height of the antenna tower in meters [m] |
MAIN VOLTAGE | Mains Voltage during the test in Volt [V] |
MAXIMUM PEAK COUNT | The maximum number of peaks to be detected |
MEASURE TIME | The measure time in milliseconds [ms] |
MEASURE TIME MODE | The Mode: Auto, Coupled or Manual |
NOTE | Note or remark made during the test |
PEAK DETECTOR | Indication whether or not the Peak detector is measured: Yes / No |
PEAK MEASURE TIME | The measurement time of the peak detector in seconds [s] |
PEAK OBSERVATION TIME | The observation time per peak in seconds [s] |
PEAK SEARCH | Indication whether or not a peak search is performed: Yes / No |
PEAK TRACE | Indication whether or not the Peak trace is measured: Yes / No |
PEAKSWEEPS | Number of peak sweeps performed |
Keyword | Description |
POINT X FREQUENCY | The frequency of point X in the peak list ( X starting from 1) |
POINT X PEAK | The peak value of point X in the peak list (X starting from 1) |
POINT X QUASI PEAK | The quasi peak value of point X in the peak list (X starting from 1) |
POINT X AVERAGE | The average value of point X in the peak list (X starting from 1) |
POLARIZATION | The polarisation of the antenna: horizontal, vertical or both |
PRESSURE | Air Pressure during the test in milliBar [mbar] |
QUASIPEAK DETECTOR | Indication whether or not the Quasi peak detector is measured: Yes/No |
QUASIPEAK MEASURE TIME | The measurement time of the quasi peak detector in seconds [s] |
QUASIPEAK OBSERVATION TIME | The observation time per quasi peak in seconds [s] |
QUASIPEAK TRACE | Indication whether or not the Quasi peak trace is measured: Yes / No |
RBW | The Radio Bandwidth in kilo Hertz [kHz] |
RBW MODE | The RBW Mode: Auto, Coupled or Manual |
RECEIVER DATA SAVE MODE | Indication whether all data is saved or only the test results |
REFERENCE LEVEL | The reference level in the unit selected by the user |
REFERENCE LEVEL MODE | The Reference Level Mode: Auto, Coupled or Manual |
RMS DETECTOR | Indication whether or not the RMS detector is measured: Yes / No |
RMS MEASURE TIME | The measurement time of the RMS peak detector in seconds [s] |
RMS OBSERVATION TIME | The observation time per RMS peak in seconds [s] |
RMS TRACE | Indication whether or not the RMS trace is measured: Yes / No |
START ANGLE | The start position in degrees |
START FREQUENCY | The start frequency in megahertz [MHz] |
STEP FREQUENCY | The step frequency in kilo Hertz [kHz] |
STEP FREQUENCY MODE | The Step frequency Mode: Auto, Coupled or Manual |
STOP ANGLE | The stop position in degrees |
STOP FREQUENCY | The stop frequency in megahertz [MHz] |
SWEEP TIME | The sweep time in milliseconds [ms] |
SWEEP TIME MODE | The Sweep Time Mode: Auto, Coupled or Manual |
TAKE START PICTURE | Indication whether or not a picture is taken at the start of the test: Yes / No |
TEMPERATURE | Temperature during the test in degrees Celsius [oC] |
TEST ENGINEER | The name of the test engineer |
TEST SITE NAME | The name of the test equipment list |
USE INTERNAL PREAMP | N/A |
USE START STOP FREQUENCY | Yes / No, if Yes: Start/Stop if No: Frequency list is used. |
VBW | The Video Bandwidth in kilo Hertz [kHz] |
VBW MODE | The Video Bandwidth Mode: Auto, Coupled or Manual |
EMISSION TABLE | Table of detected peaks and per peak: frequency, level(s), limit value, pass/fail, location |
EQUIPMENT TABLE | A table containing all used equipment |
EVENTS | Table of events which occur during a test |
EUT HEIGHT (1) | The height of the EUT in meters [m] |
SEPTUM HEIGHT (1) | The height of the septum in meters [m] |
1) GTEM Method only
Equipment for Radiated Emission Tests[edit]
The equipment keyword consists of two parts: the keyword followed by a parameter. For each keyword all parameters are valid.
Example: ANTENNA TOWER BRAND returns the brand name of the antenna tower.
Keyword | Description |
---|---|
ANTENNA ... | Specifications of the used Antenna |
ANTENNA TOWER ... | Specifications of the used Antenna Tower |
CABLE x ... | Specifications of the used Cable number [x], where x is a number between 1 to 8 |
NUMBER OF DETECTORS | The number of detectors the Receiver is able to handle simultaneously |
PRE AMPLIFIER ... | Specifications of the used Pre Amplifier |
RECEIVER TYPE | The type of receiver: Spectrum Analyser, Measurement Receiver or Scanning Receiver |
SPECTRUM ANALYZER ... | Specifications of the used Spectrum Analyser or Measurement Receiver |
TURN TABLE ... | Specifications of the used Turntable |
Where ... is one of the following parameters:
Parameter | Description |
---|---|
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
Conducted Emission[edit]
Note: | The pass/fail criteria, shown in the tables of the report generator do not take the measure uncertainty of the test setup into account. |
Conducted Emission Tests[edit]
Keyword | Description |
---|---|
"keyword or name of photo" | The name or keyword of the photo |
NUMBER OF EVENTS | The number of events that occur during a test |
PEAK DETECTION COUNT | The number of detected peaks |
TEST START TIME | The time at which the test is stopped |
TEST STOP TIME | The time at which the test is started |
TEST SITE NAME | The name of the test equipment list |
MAX HOLD GRAPH | The max hold graph of the all the traces |
MAX HOLD PEAKS GRAPH | The max hold graph of all the traces and markers |
MAX PEAK GRAPH | The max hold graph of the Peak trace |
MAX AVERAGE GRAPH | The max hold graph of the Average trace |
MAX QUASI PEAK GRAPH | The max hold graph of the Quasi Peak trace |
MAX RMS GRAPH | The max hold graph of the RMS trace |
ATTENUATOR | The attenuation of the attenuator in dB |
ATTENUATOR MODE | The Attenuator Mode: Auto, Coupled or Manual |
AVERAGE DETECTOR | Indication whether or not the average detector is measured: Yes / No |
AVERAGE MEASURE TIME | The measurement time of the average peak detector in seconds [s] |
AVERAGE OBSERVATION TIME | The observation time per average peak in seconds [s] |
AVERAGE TRACE | Indication whether or not the average trace is measured: Yes / No |
BELOW LIMITLINE OFFSET | The level of peaks to detect in dB below the limit line |
CONFIGURATION TIME | The date and time when the TSF file is saved |
CURRENT UNIT | The selected unit for current: [dBuA], [dBmA], [dBA], [uA], [mA] or [A] |
DB/DIV | N/A |
DB/DIV MODE | N/A |
DESCRIPTION | Description of the Test Setup File (TSF) |
EMISSION OPTIMIZING METHOD | N/A |
HUMIDITY | Relative Humidity during the test in percentage relative Humidity [%RH] |
INTERNAL PREAMPLIFIER | The amplification of the internal pre amplifier in [dB] |
INTERNAL PREAMPLIFIER MODE | The Internal Pre Amplifier Mode: Auto, Coupled or Manual |
LISN LINE | Which LISN line is used: Neutral, Phase 1, Phase 2 or Phase 3 |
MAIN VOLTAGE | Mains Voltage during the test in Volt [V] |
MAXIMUM PEAK COUNT | The maximum number of peaks to be detected |
MEASURE TIME | The measure time in milliseconds [ms] |
MEASURE TIME MODE | The Mode: Auto, Coupled or Manual |
NOTE | Note or remark made during the test |
PEAK DETECTOR | Indication whether or not the Peak detector is measured: Yes / No |
PEAK MEASURE TIME | The measurement time of the peak detector in seconds [s] |
PEAK OBSERVATION TIME | The observation time per peak in seconds [s] |
PEAK TRACE | Indication whether or not the Peak trace is measured: Yes / No |
PEAKSWEEPS | Number of peak sweeps performed |
PRESSURE | Air Pressure during the test in milliBar [mbar] |
QUASIPEAK DETECTOR | Indication whether or not the Quasi peak detector is measured: Yes / No |
QUASIPEAK MEASURE TIME | The measurement time of the quasi peak detector in seconds [s] |
QUASIPEAK OBSERVATION TIME | The observation time per quasi peak in seconds [s] |
QUASIPEAK TRACE | Indication whether or not the Quasi peak trace is measured: Yes / No |
Keyword | Description |
RBW | The Radio Bandwidth in kilo Hertz [kHz] |
RBW MODE | The RBW Mode: Auto, Coupled or Manual |
RECEIVER DATA SAVE MODE | Indication whether all data is saved or only the test results |
REFERENCE LEVEL | The reference level in the unit selected by the user |
REFERENCE LEVEL MODE | The Reference Level Mode: Auto, Coupled or Manual |
RMS DETECTOR | Indication whether or not the RMS detector is measured: Yes / No |
RMS MEASURE TIME | The measurement time of the RMS peak detector in seconds [s] |
RMS OBSERVATION TIME | The observation time per RMS peak in seconds [s] |
RMS TRACE | Indication whether or not the RMS trace is measured: Yes / No |
START FREQUENCY | The start frequency in megahertz [MHz] |
STEP FREQUENCY | The step frequency in kilo Hertz [kHz] |
STEP FREQUENCY MODE | The Step frequency Mode: Auto, Coupled or Manual |
STOP FREQUENCY | The stop frequency in megahertz [MHz] |
SWEEP TIME | The sweep time in milliseconds [ms] |
SWEEP TIME MODE | The Sweep Time Mode: Auto, Coupled or Manual |
TAKE START PICTURE | Indication whether or not a picture is taken at the start of the test: Yes / No |
TEMPERATURE | Temperature during the test in degrees Celsius [oC] |
TEST ENGINEER | The name of the test engineer |
USE INTERNAL PREAMP | N/A |
USE START STOP FREQUENCY | Yes / No, if Yes: Start/Stop if No: Frequency list is used. |
VBW | The Video Bandwidth in kilo Hertz [kHz] |
VBW MODE | The Video Bandwidth Mode: Auto, Coupled or Manual |
EMISSION TABLE | Table of detected peaks and per peak: frequency, level(s), limit value, pass/fail, location |
EQUIPMENT TABLE | A table containing all used equipment |
EVENTS | Table of events which occur during a test |
ABSORBING CLAMP ... (1) | Specifications of the used Absorbing Clamp |
CLAMP MOVER ... (1) | Specifications of the used Clamp Mover |
LARGEST DISTANCE | The maximum distance of the clamp in meters [m] |
SMALLEST DISTANCE | The minimum distance of the clamp in meters [m] |
STEPS | The number of steps between the minimum distance and the maximum distance |
1) Absorbing clamp method only
Equipment for Conducted Emission Tests[edit]
The equipment keyword consists of two parts: the keyword followed by a parameter. For each keyword all parameters are valid.
Example: CABLE 5 BRAND returns the brand name of cable nr. 5.
Keyword | Description |
---|---|
CABLE x ... | Specifications of the used Cable number [x], where x is a number between 1 to 8 |
LISN ... | Specifications of the used LISN |
NUMBER OF DETECTORS | The number of detectors the Receiver is able to handle simultaneously |
PRE AMPLIFIER ... | Specifications of the used Pre Amplifier |
RECEIVER TYPE | The type of receiver: Spectrum Analyser, Measurement Receiver or Scanning Receiver |
SPECTRUM ANALYZER ... | Specifications of the used Spectrum Analyser or Measurement Receiver |
Where ... is one of the following parameters:
Parameter | Description |
---|---|
BRAND | Brand of Measurement equipment |
CALIBRATION EXPIRES | Date when calibration expires of equipment, given by the user |
DESCRIPTION | Description of Measurement equipment given by the user |
DEVICE DRIVER DLL | N/A |
DEVICE DRIVER NAME | The internal name of the device driver |
HARDWARE VERSION | Hardware version of Measurement equipment |
ID | Internal ID of Measurement equipment |
INI FILE NAME | N/A |
NAME | Name of Measurement equipment |
SERIAL NUMBER | Serial number of Measurement equipment |
SOFTWARE VERSION | Software version of Measurement equipment |
SUPPORTED DEVICE TYPES | N/A |
TYPE | Type of Measurement equipment |
Excel Exporter[edit]
The EUT data can be exported using the Excel Exporter to Microsoft Excel. Press the Export button on the Reports tab of the EUT window, and the Excel Export window will open:
Selecting filename[edit]
To select the filename you want to use for saving the information press the select file button next to the red cross. A save window will appear allowing you to select the path and filename. After closing the save window the name will be displayed on the export window.
Selecting tests to be exported[edit]
You can select or deselect a test for export by checking or un-checking the checkbox in front of the name of the test. Pressing Select all will select all tests, pressing Unselect all will deselect all tests and pressing Invert selection will invert the selected. Invert means that all selected tests will be deselected and all deselect tests will be selected.
Changing the test order[edit]
The export module exports all the selected tests from the first test at the top to the last test at the bottom of the list. This order of the tests can be changed. Select the test you want to move, press the arrow up or down button and the test is moved one place up or one place down.
Export options[edit]
There are some options that can be selected when exporting the test information:
Insert header above data | With insert header above data you can select, if you want, headers above every exported column, for example signal generator level, forward power and reflected power for immunity test. |
Export EUT data | Export EUT data allows you to select, if you want, the EUT data to be exported. Only the EUT information stored in the top test can be exported. |
Include not measured columns | Include not measured columns allows you to select, if you want, not measured columns to be exported. If you want to run a macro after exporting, it may be easier to export all the columns. You can then use the same macro for a signal level, forward power level and net power level test. It is not possible to have RadiMation® run the macro automatically after the export. Deselecting exporting not measured columns will result in faster exporting of the information. |
Performing the export[edit]
Once the Export button is pressed, all the raw data of the selected tests will be exported to the selected Excel file. The exported data, it's format and the amount of data that is exported is depending on the selected tests. When the export of the data is finished, the Excel Export window will close.
Warning: | Microsoft Excel needs to be installed on the PC to export the EUT information. The version of Microsoft Excel should be greater then or equal to version 'Microsoft Excel 97'. |