Configurable AD Convertor
The Configurable AD Convertor device driver is a AD Converter which is supported by RadiMation®.
Reset | The reset code that needs to be send to device. When left blank no command will be send. |
Init | The Init code that needs to be send to device. When left blank no command will be send. |
Get Id | The code that needs to be send to device to get the identification back. A common used SCPI command is *IDN?. When left blank no command will be send. |
Trigger and Reading |
|
Trigger and Reading |
|
Readback example(s)[edit]
Receiving Regex Examples[edit]
Received information | Regex | RadiMation Readout | Note |
---|---|---|---|
U_L_N 325 | (-?[0-9.,Ee-]+) | 325 | Takes the first number. |
I_L1;12.34 | ;(-?[0-9.,Ee-]+) | 12.34 | Takes the first number after ";". |
THD_U_L1;;14,5 | ;;(-?[0-9.,Ee-]+) | 14.5 | Takes the first number after ";;". |
AC_FREQ;Channel1;1.23E3 | ;*;(-?[0-9.,Ee-]+) | 1230 | Takes the first number after the appearance of a second ";". |
There are situations where the expression "([+-]?[0-9]*\.?[0-9]+([eE][+-]?[0-9]+)?)" is not giving the wanted result. For example "C1:PAVA RMS,16.4E-3 V,OK", when using the expression the result will be 1 instead of 16.4E-3. In the given situation the expression ",([+-]?[0-9]*\.?[0-9]+([eE][+-]?[0-9]+)?)" will give the correct result. Why does this give the correct answer? When searching for the correct value there is a search for ",[value]" instead of "[value]". Why is the "," not in the ()? Because we want RadiMation® to find the value not the value with a "," in front of it. By leaving it outside the "([expression])" it does search for it but it is not part of the decoding of the value.