Release Notes/Solved items Version 2017.1
Jump to navigation
Jump to search
RadiMation version 2017.1.4[edit]
- #6093: Turntable CO3000 is not moving when setting it to make a full turn from 0 till 360 degrees
- #6798: Apply multiple testlevels at same frequency
- #7780: Exporting EUT executed tests list
- #8207: Configurable Device driver frequencies with different units
- #8244: Climat typo it should be Climate
- #8301: Unhandled exception access to the path ErrorModeFile.radilog is denied
- #8322: RPR2006C overranges during CDN voltage calibration
- #8371: 1% Stepsize in RI Manual mode is not correct when a frequency list is used
- #8382: ODBC customer database is not working anymore
- #8383: Store RADIMAT_SESSION.LOG in a PC local temporary folder
- #8389: Received power is rounded in Antenna Scan EUT Calibration
- #8397: Searching for a customer in the customer database closes the window before the customer can be selected
- #8399: Loading a multiband immunity test is not possible, unable to create VSWRGatherer
- #8415: RadiMation crash at startup after updating to 2017.1.4
- #8416: Agilent N9000A (version A.07.06) Error with GPIB
- #8426: Unable to select correct OPC channels for AD converter.
- #8435: Allow control of CANoe 9.0.65 (SP2)
- #8443: Driver: Amplifier BLMA 1060-50
- #8458: Unable to connect to radigen RADIGEN0230A
RadiMation version 2017.1.3[edit]
- #8210: Opening a RE Multiband test is taking one and a half minutes
RadiMation version 2017.1.2[edit]
- #8045: RDC files are always stored to the Global configuration path while standalone setting is used
- #8091: Improve calculation of multiband immunity graphs
- #8097: Linear and logaritmische scale setting are not saved
- #8145: Unable to show AD Channels in 2017.1.1
- #8199: Opening Multiband Immunity results takes a lot of time since graph filtering is implemented
- #8238: Language file 0.lng
- #8363: RadiLog option in view menu incorrect behaviour
RadiMation version 2017.1.1[edit]
- #506: 1 Hz on off modulation is not possible according to the DO-160E / ED-14E standards
- #2947: Amplifier is turned off when closing another multiband test
- #3032: Opening an Multiband test while performing a Multi band test is messing up the test
- #3241: RI multi band test is overwriting the previous information
- #3598: Configurable Peak Table
- #3970: Radiated emission multiband: detector from pre-measurement used during "continuous measure"
- #4001: Difficulties to differ results from 2 bands with the same frequency range in multiband immunity tests
- #4159: RBW in peak table (RE multiband)
- #4248: Error Multiband start and end frequency
- #5189: Sweeptime is used during final measurement instead of the QP measurement time
- #5216: Test started event log entry should only be added in a restarted multiband test if manual or automatic is pushed
- #5307: Despite of no changes the message "The file has changed, do you want to save changes?" is shown
- #5341: After a Manual Mode change there is undesirable regulation
- #5440: Can't zoom out after maximum zoom in at graph
- #5469: Invalid Device Driver Handle error (Kalmus 727LC)
- #5529: Invalid Device Driver Handle (Virtual) Amplifier
- #5545: Graph is not updated when switching to the second band
- #6075: During instable measurements it may happen that Peak and Quasi-Peak measurements are inconsistent
- #6191: Add an 'Add Test' button to the Sequence window, to simplify the addition of a test
- #6230: Table export only copies the time and frequency data
- #6264: Overlapping bands in MB immunity are tested multiple times when only the modulation is different
- #6352: Changing the activated detector during Continuous Measure clears the measured value of the deactivated detector
- #6449: Frequency range settings are generating an error and the configuration of the TSF is lost when a read only test is saved as new test
- #6452: Frequency array calculation of emission sweep of analyser is missing a step
- #6861: Radiated Immunity Multiband is referring to a receiver
- #6907: Improve autosave functionality that it no longer overwrites the current test data, but first makes a backup
- #7074: Possibility to change polarization of an existing calibration file
- #7077: continuous measure is using sweep time setting
- #7143: RI Multiband only shows Puls when AM is also selected
- #7147: Redoing an already performed test overwrites the previous test-results
- #7167: Amplifier linearity measurement accepted power lines hidden
- #7177: Unable to zoom graph while test is running
- #7203: A generic error occurred in GDI+
- #7214: PI windows still do not fit at full window size using an acceptable resolution
- #7242: Two electrical field graphs are shown. Which one is correct?
- #7247: Prana amplifier is not correctly being put in Operate during immunity test
- #7249: Show example of unit settings
- #7252: RadiMation Free Responsiveness
- #7254: Change Basic small controlling window for PowerMeter
- #7255: Change Basic small controlling window for Amplifier
- #7365: Minimum size of 'Burst' and 'Envelope Tracing' tabs of the VI Powermeter
- #7411: Connection state is still orange while the device is already connected
- #7441: Minimum Form Size is always set to 0,0 at runtime
- #7449: VI Powermeter error lock when removing device
- #7499: RadiMation opening EUT is slow
- #7523: PI EFT Test levels are not covering all the different measurements
- #7575: RadiLog long tests multiple log files.
- #7581: Test description of the test is not visible in the test data
- #7637: Driver: emtest UCS500-M4
- #7644: Filling the EUT information is being slow.
- #7717: Unchanged LLF is asking to be saved when closing the window.
- #7721: System attenuation gain duplicate measurements
- #7737: Report generator query keyword for the table information is not exporting any data
- #7760: Ability to merge multiple Radiated Immunity CALibration files for different frequency ranges into one
- #7768: Wrong frequency at monitoring input events
- #7769: Saving tsf as ReadOnly data lost
- #7773: Incorrect table information for frmVIPowerMeter at the ctlControlGraph table
- #7779: Overlapping bands in MB immunity are tested multiple times when only the modulation is different
- #7796: Compression Gain System Calibration default 1 amount of samples seems to result in a corrupt calibration file
- #7799: Sorting of the ctlFormattableGrid is different when new columns is added
- #7811: Clear button on the VI Fieldsensor doesn't seem to work when the table is shown
- #7812: VI Fieldsensor keeps raising error messages when the probe is turned off before it is disconnected
- #7819: No data document could be created for the test identifier: "
- #7820: Test specific templates are gone after graph customization
- #7824: Reflected power input in Multiband Immunity
- #7836: Connect button is not showing 'Connecting'
- #7842: Saving EUT file with keywords
- #7844: Incorrectly saved Test results starts the test when reviewing the Test results
- #7845: PI test EUT cable selection should be changable while TSF is read only.
- #7866: Corrupt file saving when validator failed.
- #7867: Out of memory when starting RI test
- #7878: RadiLog error report containing # in description gives error.
- #7885: Test data like notes and specific templates settings are updating or overwriting EUT overview settings
- #7886: Resizing of the Graph customization window hides some graph customization controls
- #7887: Missing keyword in Table shifts the table
- #7893: Data file is not saved every 5 minutes, when a final peakmeasurement is busy
- #7894: Radilog memory is not being swapped
- #7896: Missing last test frequency in ReportGenerator output
- #7897: Error Report send not always sending
- #7898: & sign in device driver name is not correctly shown in the EUT Monitoring dialog
- #7902: MessageBox that is shown from the testsite before actions can be shown behind the main window
- #7903: Unable to start RadiMation with incorrectly configured path
- #7904: Default table settings are stored in the user interface
- #7905: ReportGenerator Report and output file selection is not saved.
- #7908: Invalid tsf in sequence can corrupt the sequence
- #7915: Merging of calibration files looses the originally desired fieldstrength
- #7918: Graph customization window can be made too small
- #7922: External modulation should not be possible for a VI signal generator
- #7926: The RBW value has changed by the device from 120 to 100 User description:
- #7927: Duplicate more than 1 test at the same time in the new Sequence window.
- #7932: Very long filenames of the RadiLog file cannot be opened by RadiLog
- #7937: Signal generator VI frequency can be set outside the range of the controlled device
- #7940: Why is the Peak Table disabled during an Emission test?
- #7946: Opening test results directly sets the changed flag.
- #7947: Switching to a different band using 'Continue automatic mode settings' is incorrectly checking if the carrier frequency is valid
- #7950: Ability to hide Report Generator Template column for 'The keyword "" is available in the tempate' window
- #7951: Sending unprintable characters with configurable device driver
- #7953: Frequency list settings are not saved for a sequence and thus not used when Fixed power test is run from within a SEQ file
- #7955: Size of Voltage Dips and interrupts TSF window can be made too small
- #7962: RadiLog to long subject gives error. Strange behaviour occurs.
- #7963: RadiLog parsing fail
- #7964: Directly after installation, the power graphlines are not shown in the VI Powermeter
- #7965: A read only TSF is also asked to save the changes
- #7966: Last View update is being skipped
- #7969: EFT tests with repetition rate 100 kHz (burst duration 0,75ms) can NOT be performed
- #7971: Radilog saving file, file in use while reporting error.
- #7980: Test data files are zero based count on disk which is confusing for end-users
- #8003: Clear graph button for VI windows does not work (when disconnected)
- #8004: Opening of locked files should wait for a few seconds and retry opening locked files
- #8009: Opening a second CE Absorbing clamp test, switches both graphs from log to linear xaxis.
- #8011: Exporting polar graphs contains a white space area.
- #8015: Improve graphical representations of graph
- #8021: When a Band has been selected the TSF is marked as being changed
- #8029: Graphs during Multiband Immunity are not updated during test
- #8030: VI powermeter windows does not work correctly
- #8033: Combine user defined units to prevent multiple equal axis from being shown in graph
- #8040: Error window location cut off
- #8046: Error report, cant write to temporary directory
- #8053: EUT being removed after network reset.
- #8054: Manual frequency is not measured when it is exactly the same as the last frequency in the calibration file.
- #8061: Before actions are prompted multiple times at the end of the test
- #8069: Shortcutkeys not updating ctlEvents
- #8085: Gaps in graph lines.
- #8096: Auto detect peaks shows object reference error
- #8101: RadiLog SQL files containing ";" is not opening correctly
- #8104: RadiMation does not automatically refer and open the latest installed version
- #8106: RadiLog object reference after saving
- #8107: Errors are not reported in RadiMation
- #8108: Error window tooltip causes object reference error.
- #8109: Export full PEAK table
- #8112: Radilog Parsing error when opening log from zip
- #8114: Calibration Files do not use the same calibration method
- #8130: Virtual Instruments infinit loop errors
- #8137: Language files as unicode
- #8138: VDI Impedance is set incorrectly to the device
- #8140: VI Signal Generator all controls are still disabled after connected
- #8144: Exporting graph to LLF in the graph options crashes