Release Notes/Solved items Version 2024.1
Jump to navigation
Jump to search
RadiMation version 2024.1.3[edit]
- #12772: Application note 147: MIL-STD RE101
- #13138: Objects used together must be created from the same factory instance
- #13425: Fix error: Objects used together must be created from the same factory instance
- #13651: Fix update of plugin card is not working correctly in a multislot RadiCentre
- #13758: The progress of the software update of a Raditeq device is only running once from 0 % to 100 %
- #13759: The dialog cannot be closed as long as the software update of a Raditeq device is busy
- #13760: At the end of the software update of Raditeq device a messagebox is shown
- #13761: During the software update of a Raditeq device a message is shown that the update is busy
- #13984: Fix error Objects used together must be created from the same factory instance
- #13998: Fix error objects used together must be created from the same factory instance
- #14365: Loading previous Reverberation calibration files shows all the information again
- #14483: 'Suggest an improvement' redirects to the RadiMation download page
- #14498: Antenna distance exported from Multiband Calibration matches with the antenna distance used during the test
- #14507: UFA calculation stores logarithmic step frequency into resulting CAL file
- #14567: Add reseller ASTAT
- #14589: Keysight E4446A factory preset type is set during the initialisation
- #14617: Terminator is correctly skipped in binary response of Narda PMM600
- #14620: CI system calibration does not allow to set a constant current with decimals e.g. 7.5 mA
- #14632: Fix hiding controls on the virtual instrument window
- #14633: Fix display of controls on Virtual instrument window
- #14636: Fix auto triggering of RSS3018U is not performed
- #14653: FSV40 correctly set the center frequency in final measurement mode
- #14677: Driver: ETS-Lindgren HI-6023
- #14678: Add reseller Comtest SRL
- #14679: Check for system errors in NRT power meter driver
- #14694: Log the new operation mode when it is changed
- #14716: Software update can be be performed on Raditeq RadiSense Ultra
- #14731: Add reseller Netscope RM
- #14760: Fix Logging when directory configuration does not match CONFDVDR directory configuration
- #14764: Update packages
- #14768: Updates to assembly info
- #14769: Fix amplifier initialisation display mismatch
- #14772: Fix freezing when closing MB with open event window
- #14773: Improve PMM9010 communication by clear communication buffers around commands
- #14805: SRM3006 Correctly handle '\r' characters and use ';' as termination only
- #14826: Fix object used together must be created from the same factory instance
- #14855: A saved reverberation calibration file is not triggering a file corrupted error anymore
- #14872: Do not show the stirrer in the signal generator list
- #14884: More retries added to handle sudden disconnects and timeouts for Maturo FCU
- #14890: Prevented deadlock in pulsed immunity multiband EFT test
- #14899: Support for windows 10 enterprise LTSC 2019 x64 17763
- #14917: Drivers added for Raditeq RadiPol RPL3001L, RPL3001H and RPL3001R
- #14928: Resolved a problem that < 1 ms differences between different timing loops are present
RadiMation version 2024.1.2[edit]
- #8756: Virtual Instrument amplifier window. Triangle button is not drawing a triangle
- #12693: A correction file that is opened by a restricted engineer can still be modified by using TAB
- #13711: Fix for error 'Error: Objects used together must be created from the same factory instance. (Exception from HRESULT: 0x88990012)'
- #13819: Added EN61000-4-20:2022 UFA Calculation and TEM mode verification
- #13826: Update to DevExpress 23.2.3
- #13873: Driver: EMCO 5390 XYZ Positioner
- #13916: 2 or more calibration files can be opened at the same time again
- #13921: Show the default button in the Raditeq skin more distinctive
- #13967: Keysight N9038A: Alignment status is not checked during test
- #14150: Simplify selection of the type of the RadiCentre when a RadiCentre Ultra 8 is controlled
- #14283: On/Off buttons should not behave as toggle buttons
- #14315: Textboxes in word templates disappear
- #14323: Driver: Rohde & Schwarz SMB100M
- #14331: A readonly TSF file can still be saved by selecting 'Are you sure to replace it?'
- #14354: Objects used together must be created from the same factory instance. (Exception from HRESULT: 0x88990012)
- #14411: RadiCentre selection is always set to 'RadiCentre Ultra'
- #14413: Raise warning when main template is used as test specific template
- #14419: Returned value of SwitchHoldContinuousOff is always ignored
- #14437: Error while measuring with R&S FPC1500
- #14438: Objects used together must be created from the same factory instance
- #14438: Objects used together must be created from the same factory instance
- #14443: For RadiCentre devices when directly connected to the pc it is not possible to change the baudrate
- #14443: Allow baudrate change for RadiCentre1 devices connected by RS232
- #14444: No response from directly connected RadiPower
- #14446: Error while clicking table
- #14451: Fixed firmware check for the RPR2006C
- #14453: Improve battery check speed for raditower
- #14470: Error opening EUT calibration test graph "attenuation"
- #14472: Implemented a check if the Maturo FCU is enabled and referenced
- #14516: AR75S1G6C was not going to operate
- #14518: No stirrer driver in test site in normal RI MB closed loop test
- #14520: Amplifier not powering on
- #14523: Allow internal and external AM sine and square wave modulation for the R&S SMF100A generator
- #14547: Copying a limit line file table does not consider the unit when pasted into another limit line file
- #14552: Not possible to copy and paste the address information
- #14554: Driver does not read power anymore during zero operation.
- #14564: Objects used together must be created from the same factory instance. (Exception from HRESULT: 0x88990012)
- #14568: Objects used together must be created from the same factory instance. (Exception from HRESULT: 0x88990012)
- #14583: RadiSense Ultra: Add hidden advanced ability to skip range selection
- #14583: RadiSense Ultra should wait until probe is active after laser is activated
- #14584: Agilent ESG-D (E4431B) is automatically switching int/ext reference.
- #14590: Allow pasting correction data in units different from the receiving correction file
RadiMation version 2024.1.1[edit]
- #12009: Support 64 bit time stamps
- #14039: Switching band in a RI MB test using a stepper with a frequency list can be slow
- #14134: Add antenna efficiency setting to all antenna device drives.
- #14163: Objects used together must be created from the same factory instance. (Exception from HRESULT: 0x88990012)
- #14269: Controls on reverberation calibration configuration window are incorrectly aligned
- #14270: Description on the reverberation calibration configuration window is unexpected.
- #14271: Add validator if 'allowed deviation' is selected
- #14272: Add validator if at least one field probe input is selected
- #14273: Add a validator if at least one testlevel is selected
- #14274: Positioning of the field probe cannot be changed in the change order
- #14278: 'Save Calibration As' dialog is shown if reverberation calibration takes longer than 5 minutes
- #14281: Overflow is prevented when searching very large arrays
- #14292: Allignment of radiated immunity related test configurations forms
- #14320: Remove PropertyChanged events in settingbase class