ISO 11452-4
Jump to navigation
Jump to search
The ISO11452-4 standard describes the testing and measurement techniques for Bulk current injection (BCI).
Test method in short[edit]
Increase the forward power applied to the current injection probe and measure the injected current (Iref) until either
- The measured current reaches the specified test level, or
- The forward power reaches the power limit PCW limit.
The standard describes the following test method:
* Conducted immunity 100 kHz to 400 MHz - see Application Note 160: "How to perform an ISO 11452-4 BCI (Bulk Current Injection) substitution test"
Supported by RadiMation®?[edit]
This method is supported by RadiMation.