Release Notes/Solved items Version 2024.2.6
Jump to navigation
Jump to search
RadiMation version 2024.2.6[edit]
- #15034: Add option to disable automatical log-in of engineers
- #15257: Multiple measurement of the Keysight 34400-series multimeter are performed during the dwell time
- #15282: Improvements related to sharing of device stream run time configurations
- #15458: Improvements related to sharing of device stream run time configurations
- #15658: Fix N9038A raises error about SYST:PRES:FULL
- #15704: Add Ametek GTEM cell drivers
- #15756: Fix the correction file contains the column 'Attenuation' which is not allowed'
- #15796: Option to ignore connection errors when Netatmo is unavailable
- 15798: Driver: Modulation source Agilent 33511B
- #15816: Switch commands for the R&S OSP are retransmitted when an error is raised
- #15825: Show 'RadiMation 30 years' logo's on about window
- #15826: Fix TESEQ CBA 1G-300D reboots when initialised
- #15832: UCS 500N Set the nominal and reduced voltage using U- commands
- #15836: Fix FC06.1 times out after activating the tilt mode
- #15839: Updated documentation regarding usage of magnetic field antenna factor
- #15851: Edit sequence button is working again
- #15854: CWS 500N1 device driver function not implemented
- #15855: Extend Lumiloop 1.2 driver with multi axis readout functionality
- #15859: Fix index out of bounds error when pasting correction data from excel
- #15865: Updated wiki page for the "Timeout while waiting on a response that matches with the regular expression" error
- #15878: KEYSIGHT MSOX3034T select the correct channel
- #15886: Improve communication with ETS-Lindgren amplifiers
- #15983: Limit frequency to the AC/DC coupling start frequency
- #15902: Correct error handling for getinfo call for the the XYZ postioner
- #15903: innco CO2000 and CO3000 auto detection
- #15905: Powering of RS232 devices using the DTR line is now allowed by the RadiVISA layer
- #15906: HP34465A cache the max, min and last value correctly
- #15938: An item with the same key has already been added
- #15950: Driver: Rohde & Schwarz ESU/ESR/ESW/EPL Controlled LISN
- #15952: Add reseller: EM Test Solution
- #15956: AC/DC coupling selection in ESCI scanning receiver
- #15959: Driver: IFI SCCX750
- #16098: CWS500N1.3 Show errors like RR,41 when adjusting the carrier level
version 2024.2.6
- #6508: USB controlled RadiCentre does not require National Instruments VISA anymore
- #14984: R&S ESR3 Fix an error -222 when applying the RBW after the center frequency has changed
- #15624: TDEMI unexpected differences in measurement results when the pre-selector has been activated and a reduced span is being measured
- #15708: Extended the mk motion driver to support retrieval of values from OCR
- #15746: Driver Siglent spectrum analyzer model SSA5085A
- #15761: Extended the mk motion driver to support retrieval of values from OCR
- #15848: R&S OSP switching commands are retransmitted when an error has happened before
- #15907: fixes related to double inclusion of monitorig input graph lines
- #15928: MSO 3000 series fixes related to division scaling
- #15955: Device driver to check if the serial number of the tested EUT is the same as the serial number in the EUT file
- #15963: dBm is shown along the Y-axis for a radiated emission test
- #15968: Fix AC DC coupling selection for the R&S ESCI
- #15974: R&S SMCV100B changed default port and IP adress in driver settings
- #15975: Fix setting the receiver measurement time for the R&S FPL
- #15979: Fix AC DC coupling selection for the tektronix TDS scopes
- #15980: unexpected results performing the amplifier harmonics test
- #15985: Allow lower signal generator levels in harmonics eut test
- #15986: Allow lower signal generator levels in network analyser test
- 15989: Network analyser test stimilus limit removed of -20 dBm
- #15991: Performing a final measurement with multiple detectors during a GTEM test is now working correctly
- #16000: IFI SCCX750: Fixes related to initialization behavior
- #16001: RSS2000 will not send MEASMODE with probe versions older than 2.0.6
- #16004: FSW43 Do not use AUTO sweep time while in zero span
- #16008: Improvements to rounding of floating points
- #16009: Switching relay of R&S OSP, module OSP-B136 is now supported
- #16018: EUT Serial number checker, show serial numbers in correct order when they do not match
- #16020: Make RadiSense IDN checks more strict
- #16023: Driver Keysight AP5000 series
- #16027: Teseq NSG 4070 can also be controlled using the TCP/IP connection (without an installed VISA library)
- #16040: R&S ESI Data out of range;SCAN1:BAND:RES
- #16058: Serial number checker is now able to ignore communication errors
- #16064: fixed the error message 'clsCommandSendSwitchMatrixEvent is not registered'
- #16067: use longer timeout for em test CWS500N1.3 and firmware version >= v9
- #16070: Driver: Raditeq RGN2001B
- #16075: fixed the error message 'clsCommandStopRotPositioner is not registered'
- #16080: NX7 unexpected syncronisation errors
- #16082: em test CWS500N1.3 power meter driver, use longer wait times for firmware version 9 and higher
- #16084: NX7 unexpected syncronisation errors
- #16085: Fixes related to resizing of graphs in RI multiband test
- #16086: Fix Keysight 34450A and 34405A: No measurements are performed by the device
- #16095: Fix device driver system warning ranges
- #16106: Fix label for the EFT multiband test
- #16171: Verify that the correction file check uses the start frequency of the configured band, instead of the first frequency of the frequency list.