Configurable Switch Matrix

From RadiWiki
Revision as of 12:23, 3 April 2019 by Mahe (talk | contribs)
Jump to navigation Jump to search

The Configurable Switch Matrix device driver is a Switch Matrix which is supported by RadiMation®.  

Screenshot configurable switch matrix configuration window.png

For all text field applies: when a text field is left empty, no command is being send at that time.

ScreenElementDescription.svg Device Driver
ScreenElementDescription.svg Reset Text field to specify the reset command. The command is send to the device during the test initialization.
ScreenElementDescription.svg Init Text field to specify the initialize command. The command is send to the device during the test initialization.
ScreenElementDescription.svg Get ID Text field to specify the *IDN? query. The command is send to the device during the device check.
ScreenElementDescription.svg Returned ID Text field to specify the expected respond to have the Get ID compared with. The string is used during the device check in case a query is specified.
ScreenElementDescription.svg Deinit Text field to specify the deinitialize command. The command is send to the device during the test deinitialization.
ScreenElementDescription.svg Operation
ScreenElementDescription.svg During Test The command is send to the device just before starting the test.
ScreenElementDescription.svg After Test The command is send to the device after finishing the test.
ScreenElementDescription.svg After sending perform a read and discard result When selected the driver will perform a read after sending the command. Some device need to be read out before

sending the next command.

ScreenElementDescription.svg Operation Complete
ScreenElementDescription.svg Wait for Operation Completion after sending command(s) This will append the *OPC? to the commands being send.

Configurable switch matrix configuration window custom2.png

ScreenElementDescription.svg Test
ScreenElementDescription.svg Test started Text field to specify the command, which is send to the device at start of a test.
ScreenElementDescription.svg Test stopped Text field to specify the command, which is send to the device when a test has ended.
ScreenElementDescription.svg Signal
ScreenElementDescription.svg Frequency changed Text field to specify the command, which is send to the device when the frequency has changed. The __freq__ will be replaced by the frequency value in case the retrieval of the respond was successful.
ScreenElementDescription.svg Carrier Level changed Text field to specify the command, which is send to the device when the carrier level has changed. The __carrier__ will be replaced by the carrier level value in case the retrieval of the respond was successful.
ScreenElementDescription.svg Dwell-time
ScreenElementDescription.svg Dwell-time started Text field to specify the command, which is send to the device when the dwell-time has started.
ScreenElementDescription.svg Dwell-time stopped Text field to specify the command, which is send to the device when the dwell-time has stopped.
ScreenElementDescription.svg Modulation
ScreenElementDescription.svg Modulation on Text field to specify the modulation on command. The command is send to the device when the modulation must be turned on.
ScreenElementDescription.svg Modulation off Text field to specify the modulation off command. The command is send to the device when the modulation must be turned off.

Configurable switch matrix configuration window custom3.png

For the following specified commands is applicable that the __result__ will be replaced by the results in case the respond was retrieved successfully.

ScreenElementDescription.svg Measurements
ScreenElementDescription.svg Before Forward Power Text field to specify the command which will be send to the device before a Forward Power measurement.
ScreenElementDescription.svg After Forward Power Text field to specify the command which will be send to the device after a Forward Power measurement.\tKeyword __result__ will be replaced by measured Forward power in dBm
ScreenElementDescription.svg Before Reflected Power Text field to specify the command which will be send to the device before a Reflected Power measurement.
ScreenElementDescription.svg After Reflected Power Text field to specify the command which will be send to the device after a Reflected Power measurement.\tKeyword __result__ will be replaced by measured Reflected power in dBm
ScreenElementDescription.svg Net Forward Power Text field to specify the command which will be send to the device when Net Power measurement is performed.\tKeyword __result__ will be replaced by measured Net power in dBm
ScreenElementDescription.svg Field Sensor Text field to specify the command which will be send to the device when a Field Sensor measurement is performed.\tKeyword __result__ will be replaced by measured Field strength in V/m

Configurable switch matrix configuration window custom4.png

ScreenElementDescription.svg Antenna Tower
ScreenElementDescription.svg Antenna Tower started Text field to specify the command. The command is send to the device at start of movement of the Antenna Tower.
ScreenElementDescription.svg Antenna Tower stopped Text field to specify the command. The command is send to the device when the movement of the Antenna Tower stopped.
ScreenElementDescription.svg Antenna Tower changed Text field to specify the command. The command is send to the device when the Antenna Tower height has changed.
ScreenElementDescription.svg Antenna Tower polarization Text field to specify the command. The command is send to the device when the Antenna Tower Polarization has changed.
ScreenElementDescription.svg Turntable
ScreenElementDescription.svg Turntable started Text field to specify the command. The command is send to the device at start of movement of the Turntable.
ScreenElementDescription.svg Turntable stopped Text field to specify the command. The command is send to the device when the movement of the Turntable stopped.
ScreenElementDescription.svg Turntable changed Text field to specify the command. The command is send to the device when the Turntable angle has changed.