Difference between revisions of "Configurable AD Convertor"
(→Channels) |
|||
Line 17: | Line 17: | ||
== Channels == | == Channels == | ||
+ | |||
AD convertors can have multiple channels on which AD values could be read. | AD convertors can have multiple channels on which AD values could be read. | ||
For each AD channel, different commands can be set. | For each AD channel, different commands can be set. | ||
+ | === Trigger and Reading === | ||
# A trigger command can be specified to request a measurement from the device. | # A trigger command can be specified to request a measurement from the device. | ||
# A regular expression can be set to parse 1 numeric value from the returned message of the device. The parsed number will be used in RadiMation | # A regular expression can be set to parse 1 numeric value from the returned message of the device. The parsed number will be used in RadiMation | ||
Line 35: | Line 37: | ||
}} | }} | ||
− | {{ScreenElementDescription| | + | === Trigger and Reading === |
+ | {{ScreenElementDescription|Minimum and maximum value| | ||
+ | Minimum and maximum can be set to limit the measured value. | ||
+ | #!Minimum value! The minimum on which the measured value will be cut off. | ||
+ | #!Maximum value! The maximum on which the measured value will be cut off. | ||
+ | |||
{{ScreenElementDescription|Minimum value|The lowest value that can be measured with this device. The value must be the same as filled in the [[EUT]] window.}} | {{ScreenElementDescription|Minimum value|The lowest value that can be measured with this device. The value must be the same as filled in the [[EUT]] window.}} | ||
Revision as of 10:02, 6 October 2016
The Configurable AD Convertor device driver is a AD Converter which is supported by RadiMation®.
Initialisation and Check
Reset | The reset code that needs to be send to device. When left blank no command will be send. |
Init | The command that is send to initialize the configured device. When left blank no command will be send. |
Get Id | The command that is send to retrieve the ID of the device. This is used to check if the device is connected. A common used SCPI command is *IDN?. When left blank no command will be send. |
Channels
AD convertors can have multiple channels on which AD values could be read. For each AD channel, different commands can be set.
Trigger and Reading
- A trigger command can be specified to request a measurement from the device.
- A regular expression can be set to parse 1 numeric value from the returned message of the device. The parsed number will be used in RadiMation
Trigger and Readback |
The trigger and read back commands are used to receive the measured values into RadiMation
|
Trigger and Reading
Minimum and maximum value |
Minimum and maximum can be set to limit the measured value.
|
Readback example(s)
Received information
|
Regex
|
RadiMation Readout
|
Note
|
---|---|---|---|
U_L_N 325 | (-?[0-9.,Ee-]+)
|
325
|
Takes the first number.
|
I_L1;12.34 | ;(-?[0-9.,Ee-]+)
|
12.34
|
Takes the first number after ";".
|
THD_U_L1;;14,5 | ;;(-?[0-9.,Ee-]+)
|
14.5
|
Takes the first number after ";;".
|
AC_FREQ;Channel1;1.23E3 | ;*;(-?[0-9.,Ee-]+)
|
1230
|
Takes the first number after the appearance of a second ";".
|