The Configurable Switch Matrix device driver is a Switch Matrix which is supported by RadiMation®.

Links

This information about an equipment is automatically generated from the list of supported device drivers from RadiMation.
If you need more information you can contact radimation-support@raditeq.com.

Screenshot configurable switch matrix configuration window.png

For all text field applies: when a text field is left empty, no command is being send.

ScreenElementDescription.png Device Driver
ScreenElementDescription.png Reset Text field to specify the reset command. The command is send to the device during the test initialization.
ScreenElementDescription.png Init Text field to specify the initialize command. The command is send to the device during the test initialization.
ScreenElementDescription.png Get ID Text field to specify the *IDN? query. The command is send to the device during the device check.
ScreenElementDescription.png Returned ID Text field to specify the expected respond to have the Get ID compared with. The string is used during the device check in case a query is specified.
ScreenElementDescription.png Deinit Text field to specify the deinitialize command. The command is send to the device during the test deinitialization.
ScreenElementDescription.png Operation
ScreenElementDescription.png During Test The command is send to the device just before starting the test.
ScreenElementDescription.png After Test The command is send to the device after finishing the test.
ScreenElementDescription.png After sending perform a read and discard result When selected the driver will perform a read after sending the command. Some device need to be read out before

sending the next command.

ScreenElementDescription.png Operation Complete
ScreenElementDescription.png Wait for Operation Completion after sending command(s) This will append the *OPC? to the commands being send.

Configurable switch matrix configuration window custom2.png

ScreenElementDescription.png Test
ScreenElementDescription.png Test started Text field to specify the command, which is send to the device at start of a test.
ScreenElementDescription.png Test stopped Text field to specify the command, which is send to the device when a test has ended.
ScreenElementDescription.png Signal
ScreenElementDescription.png Frequency changed Text field to specify the command, which is send to the device when the frequency has changed. The __freq__ will be replaced by the frequency value in case the retrieval of the respond was successful.
ScreenElementDescription.png Carrier Level changed Text field to specify the command, which is send to the device when the carrier level has changed. The __carrier__ will be replaced by the carrier level value in case the retrieval of the respond was successful.
ScreenElementDescription.png Dwell-time
ScreenElementDescription.png Dwell-time started Text field to specify the command, which is send to the device when the dwell-time has started.
ScreenElementDescription.png Dwell-time stopped Text field to specify the command, which is send to the device when the dwell-time has stopped.
ScreenElementDescription.png Modulation
ScreenElementDescription.png Modulation on Text field to specify the modulation on command. The command is send to the device when the modulation must be turned on.
ScreenElementDescription.png Modulation off Text field to specify the modulation off command. The command is send to the device when the modulation must be turned off.

Configurable switch matrix configuration window custom3.png

For the following specified commands is applicable that the __result__ will be replaced by the results in case the respond was retrieved successfully.

ScreenElementDescription.png Measurements
ScreenElementDescription.png Before Forward Power Text field to specify the command which will be send to the device before a Forward Power measurement.
ScreenElementDescription.png After Forward Power Text field to specify the command which will be send to the device after a Forward Power measurement.
ScreenElementDescription.png Before Reflected Power Text field to specify the command which will be send to the device before a Reflected Power measurement.
ScreenElementDescription.png After Reflected Power Text field to specify the command which will be send to the device after a Reflected Power measurement.
ScreenElementDescription.png Net Forward Power Text field to specify the command which will be send to the device when Net Power measurement is performed.
ScreenElementDescription.png Field Sensor Text field to specify the command which will be send to the device when a Field Sensor measurement is performed.

Configurable switch matrix configuration window custom4.png

ScreenElementDescription.png Antenna Tower
ScreenElementDescription.png Antenna Tower started Text field to specify the command. The command is send to the device at start of movement of the Antenna Tower.
ScreenElementDescription.png Antenna Tower stopped Text field to specify the command. The command is send to the device when the movement of the Antenna Tower stopped.
ScreenElementDescription.png Antenna Tower changed Text field to specify the command. The command is send to the device when the Antenna Tower height has changed.
ScreenElementDescription.png Antenna Tower polarization Text field to specify the command. The command is send to the device when the Antenna Tower Polarization has changed.
ScreenElementDescription.png Turntable
ScreenElementDescription.png Turntable started Text field to specify the command. The command is send to the device at start of movement of the Turntable.
ScreenElementDescription.png Turntable stopped Text field to specify the command. The command is send to the device when the movement of the Turntable stopped.
ScreenElementDescription.png Turntable changed Text field to specify the command. The command is send to the device when the Turntable angle has changed.