Revision as of 15:47, 23 January 2009

Theory

Current sensor Transfer impedance Prove.PNG

The left impedance is the signal generator which is generating enough power for 1 ampere.

This 1Amp. generates in the right impedance.

The current sensor has 1 ohm transfer impedance, this means 1 ampere generates 1 Volt on the measuring part below.

The power in the lower 50 ohm impedance is

So 1 ohm:

Reference measurement

Current sensor Transfer impedance Ref measurement.PNG

Probe measurement

Current sensor Transfer impedance final measurement.PNG

Calculation

and in dBm.


Example

On 10 MHz we have the following information:

  • Calibration: 0 dBm.
  • Measurement: -27,96 dBm.

So:

Verification

Information.png
Note: This method is not a replacement for a real calibration.