The left impedance is the signal generator which is generating enough power for 1 ampere.
 +
 +
This 1 Ampere generates <math>P = I^2*R=50 \ Watt</math> in the right impedance.
 +
 +
The current sensor has 2 ohm transfer impedance, this means 1 ampere generates 2 Volt on the measuring part below.
 +
 +
The power in the lower 50 ohm impedance is <math>P = \frac{U^2}{R} = 80 \ mWatt</math>
 +
 +
So 2 ohm: <math>10*^{10}log(\frac{0,08}{50}) \approx -27,96 dB</math>
 +
 +
The difference is <math>-27,96 - (-33,98) = 6,02 dB</math>
 +
 +
'''Conclusion:'''
 +
 +
Correction to a 1 ohm impedance is <math>20*^{10}log(R_{probe})</math>
  
  
 
{{note|This method is not a replacement for a real calibration.}}
 
{{note|This method is not a replacement for a real calibration.}}

Revision as of 15:56, 23 January 2009

Theory

Current sensor Transfer impedance Prove.PNG

The left impedance is the signal generator which is generating enough power for 1 ampere.

This 1Amp. generates in the right impedance.

The current sensor has 1 ohm transfer impedance, this means 1 ampere generates 1 Volt on the measuring part below.

The power in the lower 50 ohm impedance is

So 1 ohm:

Reference measurement

Current sensor Transfer impedance Ref measurement.PNG

Probe measurement

Current sensor Transfer impedance final measurement.PNG

Calculation

and in dBm.


Example

On 10 MHz we have the following information:

  • Calibration: 0 dBm.
  • Measurement: -27,96 dBm.

So:

Verification

The left impedance is the signal generator which is generating enough power for 1 ampere.

This 1 Ampere generates in the right impedance.

The current sensor has 2 ohm transfer impedance, this means 1 ampere generates 2 Volt on the measuring part below.

The power in the lower 50 ohm impedance is

So 2 ohm:

The difference is

Conclusion:

Correction to a 1 ohm impedance is


Information.png
Note: This method is not a replacement for a real calibration.