Difference between revisions of "Device Types"

From RadiWiki
Jump to: navigation, search
Line 37: Line 37:
 
The EUT controller is used for controlling the EUT during immunity measurements
 
The EUT controller is used for controlling the EUT during immunity measurements
 
All supported EUT controller devices can be found [[:Category:EUT Controller|here]]
 
All supported EUT controller devices can be found [[:Category:EUT Controller|here]]
 +
 +
= Field Sensor =
 +
The field sensor is used for measuring the field generated during a radiated immunity measurement.
 +
All supported field sensor devices can be found [[:Category:Field Sensor|here]]
  
 
= Forward Power Meter =
 
= Forward Power Meter =
Line 77: Line 81:
 
The Output power meter is used for measuring the output power during an immunity measurement, used in a strip line set up.
 
The Output power meter is used for measuring the output power during an immunity measurement, used in a strip line set up.
 
All supported output power meter devices can be found [[:Category:Power Meter|here]]
 
All supported output power meter devices can be found [[:Category:Power Meter|here]]
 +
 +
= Pre Amplifier =
 +
The pre amplifier is used to amplify the incoming signals.
 +
All supported amplifier devices can be found [[:Category:Pre Amplifier|here]]
  
 
= Reflected Power Meter =
 
= Reflected Power Meter =
Line 85: Line 93:
 
The resistor is used to monitor voltage over a coil during MIL STD testing.  
 
The resistor is used to monitor voltage over a coil during MIL STD testing.  
 
All supported resistor  can be found [[:Category:Resistor|here]]
 
All supported resistor  can be found [[:Category:Resistor|here]]
 +
 +
= Sensor Power Meter =
 +
The sensor power meter is used for measuring the power at the current sensor during an immunity measurement.
 +
All supported sensor power meter devices can be found [[:Category:Power Meter|here]]
  
 
= Signal Generator =
 
= Signal Generator =
The signal generator is used to generate power for immunity tests  
+
The signal generator is used to generate power for immunity tests.
 
All supported signal generator devices can be found [[:Category:Signal Generator|here]]
 
All supported signal generator devices can be found [[:Category:Signal Generator|here]]
 +
 +
= Spectrum Analyser =
 +
The spectrum analyser is used to receive the emission coming from the [[EUT]].
 +
All supported spectrum analyser devices can be found [[:Category:Spectrum Analyser|here]]
  
 
= Switch matrix =
 
= Switch matrix =

Revision as of 12:41, 19 December 2007

A/D converter

The A/D convertor is used to monitor the EUT during testing. All supported A/D converter devices can be found here

Absorbing Clamp

The absorbing clamp is used measure the conducted emission All absorbing clamp devices can be found here

Amplifier

The amplifier is used to generate power for immunity tests All supported amplifier devices can be found here

Antenna

The antenna is used to send or receive signals All supported antenna devices can be found here

Antenna Tower

The antenna tower is used to move the antenna in height and change the polarisation All supported antenna tower devices can be found here

Calibration Antenna

The calibration antenna is used magnetic field calibration. All supported calibration antenna devices can be found here

Clamp Positioner

The clamp positioner is used position the absorbing clamp for the measurement All clamp positioner devices can be found here

Coupler

The coupler is used for coupling the power meter to be measured power. All supported coupler devices can be found here

Current Sensor

The current sensor is used for measuring the current in a cable. All supported current sensor devices can be found here

EUT Controller

The EUT controller is used for controlling the EUT during immunity measurements All supported EUT controller devices can be found here

Field Sensor

The field sensor is used for measuring the field generated during a radiated immunity measurement. All supported field sensor devices can be found here

Forward Power Meter

The forward power meter is used for measuring the forward power during an immunity measurement. All supported forward power meter devices can be found here

Injection Device

The injection device is used for injecting the power into cables. All supported injection devices can be found here

Jig

The Jig is used for calibrating the injection devices. All supported Jig devices can be found here

LISN

The LISN is used for measuring conducted emissions All supported LISN devices can be found here

Modulation Source

The modulation source is used as an external modulator for the signal generator. All supported modulation source devices can be found here

Multimeter

The multimeter is used to monitor voltage over a coil during MIL STD testing. All supported multimeter devices can be found here

Network Analyser

The network analyser is used for specialized calibration tests. All supported network analyser devices can be found here

Oscilloscope

The oscilloscope is used to monitor voltage over a coil during MIL STD testing. All supported oscilloscope devices can be found here

Output Coupler

The output coupler is used for coupling the output power meter to be measured power, used in a strip line set up. All supported output coupler devices can be found here

Output Power Meter

The Output power meter is used for measuring the output power during an immunity measurement, used in a strip line set up. All supported output power meter devices can be found here

Pre Amplifier

The pre amplifier is used to amplify the incoming signals. All supported amplifier devices can be found here

Reflected Power Meter

The reflected power meter is used for measuring the reflected power during an immunity measurement. All supported forward power meter devices can be found here

Resistor

The resistor is used to monitor voltage over a coil during MIL STD testing. All supported resistor can be found here

Sensor Power Meter

The sensor power meter is used for measuring the power at the current sensor during an immunity measurement. All supported sensor power meter devices can be found here

Signal Generator

The signal generator is used to generate power for immunity tests. All supported signal generator devices can be found here

Spectrum Analyser

The spectrum analyser is used to receive the emission coming from the EUT. All supported spectrum analyser devices can be found here

Switch matrix

The switch matrix is used to create the signal path of the emitted or received signal All supported switch matrix devices can be found here

Turn Table

The Turn Table is used to turn the EUT in the correct position. All supported turn table devices can be found here