Difference between revisions of "RadiMation Application Note 100"

From RadiWiki
Jump to: navigation, search
(Enhanced Status Window)
(Parameters)
Line 14: Line 14:
  
 
* Frequency
 
* Frequency
* Signal generator
+
* Signal Power
* Antenna distance
+
* Forward Power
* Antenna height
+
* Reflected Power
* Forward power
+
* Modulation
* Reflected power
+
* Average Field
 +
* Calculated Field
 +
* Voltage
 +
* Calculated Voltage
 +
* Current
 +
* Calculated Current
 +
* Measured Magnetic Field
 +
* Generated Magnetic Field
 +
* Out Power
 +
* Harmonic Frequency
 +
* Received Power At Antenna
 +
* Desired Antenna Height
 +
* Progress Antenna Height
 +
* Power Offset Due To Conservation
 +
 
 +
* AD Channel 1
 +
* AD Channel 2
 +
* AD Channel 3
 +
* AD Channel 4
 +
* AD Channel 5
 +
* AD Channel 6
 +
* AD Channel 7
 +
* AD Channel 8
 +
 
 +
* Field Sensor 1
 +
* Field Sensor 2
 +
* Field Sensor 3
 +
* Field Sensor 4
 +
* Field Sensor 5
 +
* Field Sensor 6
 +
* Field Sensor 7
 +
* Field Sensor 8
  
 
[[Category:RadiMation Application Note]]
 
[[Category:RadiMation Application Note]]
 
[[Category:RadiMation]]
 
[[Category:RadiMation]]

Revision as of 10:18, 18 June 2015

Enhanced Status Window

This Application Note will explain how the Enhanced Status Window settings can be configured in RadiMation®. It is used by the EMC test engineer to provide clear status information during automatic EMC testing. At moment of writing the Enhanced Status Window is only implemented for the Singleband tests and will therefore not (correctly) work for the Multiband tests.

Configuration

The configure this feature or to completely enable or disable it, go from the RadiMation® main menu to:

   Menu.png Configuration
      Menu.png Configuration
         Menu.png Enhanced Status Window

Adding items

It is possible to add different parameters, which are available during a test. For example, the current frequency. To show the current frequency throughout the test, type "Frequency" in the text box and press the 'add' button. The item is now added to the list. It is possible to add this item multiple times, which will result that the information is also shown multiple times.

Parameters

  • Frequency
  • Signal Power
  • Forward Power
  • Reflected Power
  • Modulation
  • Average Field
  • Calculated Field
  • Voltage
  • Calculated Voltage
  • Current
  • Calculated Current
  • Measured Magnetic Field
  • Generated Magnetic Field
  • Out Power
  • Harmonic Frequency
  • Received Power At Antenna
  • Desired Antenna Height
  • Progress Antenna Height
  • Power Offset Due To Conservation
  • AD Channel 1
  • AD Channel 2
  • AD Channel 3
  • AD Channel 4
  • AD Channel 5
  • AD Channel 6
  • AD Channel 7
  • AD Channel 8
  • Field Sensor 1
  • Field Sensor 2
  • Field Sensor 3
  • Field Sensor 4
  • Field Sensor 5
  • Field Sensor 6
  • Field Sensor 7
  • Field Sensor 8