Difference between revisions of "RadiMation Application Note 121"

From RadiWiki
Jump to: navigation, search
(Created page with "= How to measure amplifier harmonics using RadiMation = In this application note we explain how you can use RadiMation to perform accurate measurement of the harmonics that ar...")
 
(Using RadiMation free to read out the PowerMeter)
 
(47 intermediate revisions by 3 users not shown)
Line 1: Line 1:
= How to measure amplifier harmonics using RadiMation =
+
= Using a RadiPower powermeter stand-alone with {{RadiMation}} free =
In this application note we explain how you can use RadiMation to perform accurate measurement of the harmonics that are generated by an amplifier.
+
In this application note we explain how you can configure {{RadiMation}} free to perform measurements with the RadiPower.
  
 
== Overview ==
 
== Overview ==
There are two ways to measure amplifier harmonics.
+
Our powermeters are intended to be used in an automated test-setup. And they can also be used in a stand-alone mode to measure power. To use it stand-alone mode you need to install the drivers, install RadiMation free, add the power meter in RadiMation and set it up. This application note will describe all these actions, step by step.
#Measure the initial power on the first harmonic and the rest of the harmonics with a spectrum analyser.
 
#Measure the initial power with a broadband power meter and measure the harmonics with a spectrum analyser.
 
  
A schema of the test setup:
+
== Installing the software ==
  
[[File:Harmonics schematic.png]]
+
=== Download RadiMation free ===
 +
RadiMation is available for download, without requiring a license. Without a license, RadiMation will start in free mode. If RadiMation is running in free mode, will be shown on top of the RadiMation window.  
  
== Configuring the testsite ==
+
[[File:RadimationFree.png]]
=== Using a spectrum analyser ===
 
To use only the spectrum analyser we need to configure the the Forward power meter to be the spectrum analyser device driver in the testsite.
 
Keep in mind to not select any device for the sensor power meter on the second tab.
 
  
[[File:Harmonics_Configure_Spectrum_analyser_as_power_meter.PNG]]
+
In this free mode, the RadiMation functions are limited, but it is possible to use the RadiPower in stand-alone mode.
  
=== Using a broadband powermeter and a spectrum analyser ===
+
A [[Main_Page|download link]] to the latest RadiMation version, is available on our [[Main_Page|support website]].
When using the powermeter to setup the required testlevel and a spectrum analyser to measure the harmonics we need to setup the forward power meter to the power meter and on the devices 2 tab we select the spectrum analyser.
 
  
[[File:Harmonics_Configure_Broadband_power_meter.PNG]]
+
The RadiMation download will also include the driver for the RadiPower.
  
[[File:Harmonics_Configure_Spectrum_Analyser_as_Sensor_Power_meter.PNG]]
+
=== Installing the USB driver for the RPR PowerMeter ===
 +
Use the supplied USB cable to connect the sensor to your computer. Microsoft Windows will prompt that new hardware has been found.
 +
The USB-driver for the RadiPower® is Windows certified and will be loaded automatically from the Microsoft Windows update website.  
  
== Configuring the test ==
+
If the drivers are not loaded automatically, the drivers can be installed manually from the supplied USBkey.
To start the harmonics test open a EUT file and choose the menu:
+
Follow the normal instructions from Windows to install the drivers manually.
{{Menu|Calibration|EUT Calibration|Harmonics}}
 
  
[[File:Harmonics_configure_test.png]]
+
Additional information regarding installing the RadiPower®, can be found in the [https://www.raditeq.com/raditeq-downloads/radipower-series/ RadiPower manual].
  
== Test results ==
+
Once the drivers are loaded successfully, the RadiPower® should be shown in Windows Device Manager, under the 'Universal Serial Bus controllers' section.
In the test results it is possible to show the forward power measured.
 
When only using a spectrum analyser this will be the same as the first harmonic and when also using the broadband power meter this of course will be the broadband power measured.
 
  
[[File:Harmonics_test_results.PNG]]
+
[[File:device_manager.png]]
 +
 
 +
== Configuring the software ==
 +
After installing the driver and RadiMation Free, some additional configuration of RadiMation needs to be performed, to be able to use the RadiPower device. When executing this step, make sure that the RadiPower device is connected.
 +
 
 +
=== Installing and configuring the driver in RadiMation free ===
 +
Start-up RadiMation® Free. To begin, add the power meters, which will be used for the measurements, in the configuration. From the menu bar select {{ScreenElement|Configuration}} and select {{ScreenElement|Configuration}} again.
 +
 
 +
[[File:Config-Config.png]]
 +
 
 +
In the configuration window, select the {{ScreenElement|device drivers}} tab and select {{ScreenElement|power meters}} from the drop down box.
 +
 
 +
[[File:devicedrivers.png|700px]]
 +
 +
Press the {{ScreenElement|Add}} button. From the list, search for “Raditeq RPRxxxxX” and select this power meter.
 +
After selecting the type, you need to enter a name. Multiple power meters of the same type brand and model can be used at the same time, however they each need to have a unique name.
 +
 
 +
[[File:ConfigList.png|700px]]
 +
 
 +
{{Warning|Make sure that the power meter is detected by windows, and shown in device manager}}
 +
A Device Driver Settings window will now appear. Press the advanced button, to open the settings specifically for this device.
 +
Ensure {{ScreenElement|Communication}} tab is selected. In {{ScreenElement|Communication Streams}}, select {{ScreenElement|USB}}.
 +
Make sure that only one RadiPower is connected and press {{ScreenElement|Detect}}. The Device Identifier will be requested, updated in the window, and saved.
 +
 
 +
[[File:detect.png]]
 +
 
 +
{{Warning|The USB device is detected, however the PowerMeter will not work until it is specified how the PowerMeter is connected.}}
 +
 
 +
We now need select the {{ScreenElement|RadiCentre}} tab and select {{ScreenElement|Directly to PC}}.
 +
 
 +
[[File:communication.png]]
 +
 
 +
You now may configure additional options:
 +
* Select the {{ScreenElement|Option}} tab and set the desired filter for CW measurements, for example: Filter 5.
 +
 
 +
After configuring, press {{ScreenElement|OK}} to save and return to the Device Driver Settings Window.
 +
Perform a final check, by pressing the {{ScreenElement|Check}} button. The RadiPower® should now be ready to be used.
 +
 
 +
[[File:check.png]]
 +
 
 +
When the device returns "The check for this device has passed" then the device is correctly configured and RadiMation confirms that the communication is working.
 +
 
 +
== Using RadiMation free to read out the PowerMeter ==
 +
The software and the hardware are now installed,, and also the device has been added to RadiMation and it is checked that it works.
 +
Now the power meter can be used to measure power and read the measurement.
 +
 
 +
* Go to {{ScreenElement|Devices}} and open {{ScreenElement|Power meters}}
 +
* Select the power meter you have just configured (In this example we named the driver: "StandAlone PowerMeter")
 +
 
 +
[[File:DevicesPowermeter.png]]
 +
 
 +
This opens a device window for the power meter:
 +
 
 +
[[File:Stanalonepowermeter.png|700px]]
 +
 
 +
Make sure that the device is connected to your machine via USB. Click on {{ScreenElement|Connect}} to open the connection to the RadiPower.
 +
The red bar will become yellow, while it is connecting. When it is connected correctly it changes green and the button displays {{ScreenElement|Connected}}.
 +
 
 +
[[File:Powermeterconnected.png|700px]]]
 +
 
 +
Once the powermeter is connected, you can read out the values from the power meter. This can be done manually by hitting the {{ScreenElement|Trigger}} button.
 +
This will give you 1 sample of the signal. To measure continuously set the triggering to {{ScreenElement|Auto}}. The default interval is 1s, but this can be changed to any other interval.
 +
 
 +
[[file:AutoPolling.png|700px]]
 +
 
 +
== Additional information ==
 +
The power meter has now been successfully set up and the first test was successful. For more information see the links below.
 +
 
 +
* RadiMation Application Note 106: [[RadiMation Application Note 106|Powermeter parameter configuration]]
 +
* RadiPower product page: [https://www.raditeq.com/raditeq-downloads/radipower-series/ Manuals + Datasheet]
 +
 
 +
If there are any issues please contact RadiMation support. This can be done by sending an e-mail to {{MailSupport}}.
  
 
[[Category:RadiMation Application Note]]
 
[[Category:RadiMation Application Note]]
 
[[Category:RadiMation]]
 
[[Category:RadiMation]]

Latest revision as of 13:24, 27 July 2022

Using a RadiPower powermeter stand-alone with RadiMation® free

In this application note we explain how you can configure RadiMation® free to perform measurements with the RadiPower.

Overview

Our powermeters are intended to be used in an automated test-setup. And they can also be used in a stand-alone mode to measure power. To use it stand-alone mode you need to install the drivers, install RadiMation free, add the power meter in RadiMation and set it up. This application note will describe all these actions, step by step.

Installing the software

Download RadiMation free

RadiMation is available for download, without requiring a license. Without a license, RadiMation will start in free mode. If RadiMation is running in free mode, will be shown on top of the RadiMation window.

RadimationFree.png

In this free mode, the RadiMation functions are limited, but it is possible to use the RadiPower in stand-alone mode.

A download link to the latest RadiMation version, is available on our support website.

The RadiMation download will also include the driver for the RadiPower.

Installing the USB driver for the RPR PowerMeter

Use the supplied USB cable to connect the sensor to your computer. Microsoft Windows will prompt that new hardware has been found. The USB-driver for the RadiPower® is Windows certified and will be loaded automatically from the Microsoft Windows update website.

If the drivers are not loaded automatically, the drivers can be installed manually from the supplied USBkey. Follow the normal instructions from Windows to install the drivers manually.

Additional information regarding installing the RadiPower®, can be found in the RadiPower manual.

Once the drivers are loaded successfully, the RadiPower® should be shown in Windows Device Manager, under the 'Universal Serial Bus controllers' section.

Device manager.png

Configuring the software

After installing the driver and RadiMation Free, some additional configuration of RadiMation needs to be performed, to be able to use the RadiPower device. When executing this step, make sure that the RadiPower device is connected.

Installing and configuring the driver in RadiMation free

Start-up RadiMation® Free. To begin, add the power meters, which will be used for the measurements, in the configuration. From the menu bar select Configuration and select Configuration again.

Config-Config.png

In the configuration window, select the device drivers tab and select power meters from the drop down box.

Devicedrivers.png

Press the Add button. From the list, search for “Raditeq RPRxxxxX” and select this power meter. After selecting the type, you need to enter a name. Multiple power meters of the same type brand and model can be used at the same time, however they each need to have a unique name.

ConfigList.png

Warning-48px.png
Warning: Make sure that the power meter is detected by windows, and shown in device manager

A Device Driver Settings window will now appear. Press the advanced button, to open the settings specifically for this device. Ensure Communication tab is selected. In Communication Streams, select USB. Make sure that only one RadiPower is connected and press Detect. The Device Identifier will be requested, updated in the window, and saved.

Detect.png

Warning-48px.png
Warning: The USB device is detected, however the PowerMeter will not work until it is specified how the PowerMeter is connected.

We now need select the RadiCentre tab and select Directly to PC.

Communication.png

You now may configure additional options:

  • Select the Option tab and set the desired filter for CW measurements, for example: Filter 5.

After configuring, press OK to save and return to the Device Driver Settings Window. Perform a final check, by pressing the Check button. The RadiPower® should now be ready to be used.

Check.png

When the device returns "The check for this device has passed" then the device is correctly configured and RadiMation confirms that the communication is working.

Using RadiMation free to read out the PowerMeter

The software and the hardware are now installed,, and also the device has been added to RadiMation and it is checked that it works. Now the power meter can be used to measure power and read the measurement.

  • Go to Devices and open Power meters
  • Select the power meter you have just configured (In this example we named the driver: "StandAlone PowerMeter")

DevicesPowermeter.png

This opens a device window for the power meter:

Stanalonepowermeter.png

Make sure that the device is connected to your machine via USB. Click on Connect to open the connection to the RadiPower. The red bar will become yellow, while it is connecting. When it is connected correctly it changes green and the button displays Connected.

Powermeterconnected.png]

Once the powermeter is connected, you can read out the values from the power meter. This can be done manually by hitting the Trigger button. This will give you 1 sample of the signal. To measure continuously set the triggering to Auto. The default interval is 1s, but this can be changed to any other interval.

AutoPolling.png

Additional information

The power meter has now been successfully set up and the first test was successful. For more information see the links below.

If there are any issues please contact RadiMation support. This can be done by sending an e-mail to radimation-support@raditeq.com.