= The 'Variable' test-level is not supported. Use a 'Constant' test-level. = | = The 'Variable' test-level is not supported. Use a 'Constant' test-level. = | ||
− | When an antenna scan calibration is performed, this can be performed with the 'signal generator method' or the 'network | + | When an antenna scan calibration is performed, this can be performed with the 'signal generator method' or the 'network analyser method'. |
− | * Signal generator method: will control the signal generator to regulate the forward power to the desired power level, and measure with the spectrum | + | * Signal generator method: will control the signal generator to regulate the forward power to the desired power level, and measure with the spectrum analyser on the receiving antenna. |
− | * Network | + | * Network analyser method: will only use the network analyser to generate a power level on one port, and measure the received signal on the receiving antenna with the other port. |
− | If a network | + | If a network analyser is present in the selected testsite the 'Network analyser method' will be used, otherwise the 'Signal generator method' will be used. |
− | This error indicates that a variable test-level is selected in the TSF, in combination with the 'Network | + | This error indicates that a variable test-level is selected in the TSF, in combination with the 'Network analyser method'. When the 'Network analyser method' is used, it is only allowed to use the 'Constant' 'test-level'. |
== Solution == | == Solution == | ||
* Select the 'Constant' 'Test-level'. | * Select the 'Constant' 'Test-level'. | ||
− | * Use the 'Signal generator method', by removing the 'Network | + | * Use the 'Signal generator method', by removing the 'Network analyser' device driver from the selected testsite. |
[[Category:RadiMation]] | [[Category:RadiMation]] | ||
[[Category:RadiMation Error]] | [[Category:RadiMation Error]] |
Latest revision as of 09:19, 3 January 2020
The 'Variable' test-level is not supported. Use a 'Constant' test-level.
When an antenna scan calibration is performed, this can be performed with the 'signal generator method' or the 'network analyser method'.
- Signal generator method: will control the signal generator to regulate the forward power to the desired power level, and measure with the spectrum analyser on the receiving antenna.
- Network analyser method: will only use the network analyser to generate a power level on one port, and measure the received signal on the receiving antenna with the other port.
If a network analyser is present in the selected testsite the 'Network analyser method' will be used, otherwise the 'Signal generator method' will be used.
This error indicates that a variable test-level is selected in the TSF, in combination with the 'Network analyser method'. When the 'Network analyser method' is used, it is only allowed to use the 'Constant' 'test-level'.
Solution
- Select the 'Constant' 'Test-level'.
- Use the 'Signal generator method', by removing the 'Network analyser' device driver from the selected testsite.