RadiMation Error: 805306944

From RadiWiki
Revision as of 17:47, 16 February 2021 by Joro (talk | contribs) (Created page with "= GPIB system driver error (EDVR): Virtual machine/USB connection problem = A RadiMation device driver is trying to control a GPIB device through a GPIB board. However an...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

GPIB system driver error (EDVR): Virtual machine/USB connection problem

A RadiMation device driver is trying to control a GPIB device through a GPIB board. However an error is raised by the GPIB system driver that controls that GPIB board. The driver has detected that the the link to the USB based GPIB controller is suddenly lost. This for example can happen when a virtual machine is used and from which the connection was suddenly interrupted.

Solution

When a National Instruments GPIB board is used, the configuration of the GPIB board can be checked and changed in the NI-MAX software.

  • Check if the GPIB device is still present and available in the NI-MAX software.
  • Disconnect and connect the GPIB device again.