Release Notes/Solved items Version 2015.1

From RadiWiki
Revision as of 11:33, 15 April 2015 by Joro (talk | contribs)
Jump to: navigation, search

RadiMation version 2015.1.5

  • #3864: Init of the multiband test is not using the amplifier driver of the amplifier manager
  • #5590: Include option to download latest drivers.exe in RadiMation setup program
  • #5602: Include option to overrule drivers.exe included in RadiMation setup program
  • #5826: Error 76: Could not find a part of the path (..)
  • #5828: Opening a TSF file from a sequence is suddenly changing focus at the sequence window again
  • #5830: Test file is corrupted after opening and saving
  • #5831: Unexpected forward- and sensor power measurements during calibration
  • #5896: Showing graph and table information is making the performed test extremely slow
  • #5909: Configuration of Narrow band / broad band detection according to standards has disappeared
  • #5922: Update Copyright information of device drivers setup
  • #5928: Current Closed loop method is not correctly controlling/reading the sensor power meter
  • #5931: Data files of a RI Multiband test are corrupted after editing the note
  • #5959: Driver: Narda PMM EP408 Field probe

RadiMation version 2015.1.4

  • #2249: Not possible to set limit line from 500 Hz to 900 Hz
  • #4019: Unexpected CIC errors
  • #4733: No trace of the measurement data visible
  • #4748: QP measurements seems to be wrong
  • #5406: Peaks are detected outside the graph trace
  • #5563: Continuously measuring envelope power of the RadiPower results in memory problems
  • #5684: Unexpected high noise floor with CXA 9000A
  • #5818: Driver for R&S ESPC not working anymore after updating drivers.exe
  • #5821: VI Powermeter: Burst Graph doesn't show the graph by default
  • #5823: Driver: Teseq NSG 4070 as Amplifier and Powermeters
  • #5826: Error 76: Could not find a part of the path (..)
  • #5827: TSF files can't be deleted, delete and Ok buttons are always disabled
  • #5837: How can the field sensor be corrected by a RadiMation file?
  • #5846: R&S ESRP error Data out of range during time setting
  • #5848: Does the modulation needs to be turned off and on during each frequency step?
  • #5849: How can a customized warning message be shown?
  • #5857: GPIB Hibernated NI Drivers error required PC restart and loss of data
  • #5860: Frequency range of Agilent N5171B Signal Generator
  • #5862: How to add the correction for the emission antenna VW TL81000?
  • #5868: RadiMation is crashing when device is not connected

RadiMation version 2015.1.3

  • #5642: Driver Teseq NSG 4070 as Signal Generator
  • #5736: No trace data obtained from measurements with FSV13
  • #5739: Cursor information is no longer shown
  • #5778: Rigol spectrum analyser as powermeter is using pre-amp
  • #5780: Control of the Maturo antenna tower is not working if it is controlled with a LAN-to-GPIB convertor
  • #5790: Final measurement of QP detector on R&S ESI always returns 0 dBuV
  • #5797: R&S SME03 Specific system errors Level over range and ALC failure
  • #5800: Windows XP is not supported anymore
  • #5801: Detection if zeroing of RadiSense4 probe is finished takes a long time
  • #5803: Controls of the VI Powermeter are not reenabled if the auto-trigger is disabled during the re-trigger wait time
  • #5805: Old test results cannot be loaded in 2015.1.2
  • #5816: Rigol spectrum analyser pre-amp settings can't be controlled

RadiMation version 2015.1.2

  • #5787: Selection of another TSF folder doesn't update the list of TSF's in that folder
  • #5791: Uniform Field Area Calculation is not working for Constant Power method calibration files

RadiMation version 2015.1.1

  • #5775: Driver R&S switch matrix for amplifier BBA100 interlocks