Difference between revisions of "RadiMation Application Note 114"

From RadiWiki
Jump to: navigation, search
(Created page with '= Measuring data from the EUT using the Configurable AD Convertor device driver = This Application Note explains how {{RadiMation}} can be configured to protect changes in the co…')
 
Line 14: Line 14:
 
[[Category:RadiMation Application Note]]
 
[[Category:RadiMation Application Note]]
 
[[Category:RadiMation]]
 
[[Category:RadiMation]]
 +
 +
 +
= How to configure a Configurable AD Convertor =
 +
 +
<!-- Include a space to get a newline!! --> <!-- Beware of the space!! -->
 +
 +
<div style="text-align: left; direction: ltr; margin-left: 2em;">[[Image:Configurable AD Converter Configuration Window.png]]</div>
 +
 +
== 1 Specify the communication type ==
 +
 +
First the communication type must be configured.
 +
 +
<div style="text-align: left; direction: ltr; margin-left: 2em;">[[File:ConfigureCommunication.png]]</div>
 +
 +
== 2 Configure the initialization of the device ==
 +
 +
{{ScreenElementDescriptionStart}}
 +
{{ScreenElementDescription|Reset|The reset code that needs to be send to device. When left blank no command will be send.}}
 +
{{ScreenElementDescription|Init|The Init code that needs to be send to device. When left blank no command will be send.}}
 +
{{ScreenElementDescription|Get Id|The code that needs to be send to device to get the identification back. A common used [[SCPI]] command is *IDN?. When left blank no command will be send.}}
 +
{{ScreenElementDescriptionEnd}}
 +
 +
 +
 +
== 3 Configure the data readout of the device ==
 +
 +
{{ScreenElementDescription|Trigger and Reading|
 +
 +
{{ScreenElementDescription|Trigger|The command need to trigger the measurement. A common used [[SCPI]] is *TRG. When left blank no command will be send.}}
 +
 +
{{ScreenElementDescription|Read Back|In the read back the returned information is defined. This is different for every type of machine there for {{radimation}} used [[regular expressions]] to understand the format. A good regular expression for finding the first number in scientific notation in a text is:
 +
 +
'''([+-]?[0-9]*\.?[0-9]+([eE][+-]?[0-9]+)?)'''
 +
 +
For more possibilities see the example section
 +
}}
 +
}}
 +
 +
{{ScreenElementDescription|Trigger and Reading|
 +
 +
{{ScreenElementDescription|Minimum value|The lowest value that can be measured with this device. The value must be the same as filled in the [[EUT]] window.}}
 +
 +
{{ScreenElementDescription|Maximum value|The highest value that can be measured with this device. The value must be the same as filled in the [[EUT]] window.}}
 +
 +
}}
 +
 +
== 4 Configure multiple channels for 1 device ==
 +
 +
 +
== Examples ==
 +
 +
{| class="Regex example table"
 +
|-
 +
! <div style="text-align: left; direction: ltr; margin-left: 0em;">Received information</div>
 +
! <div style="text-align: left; direction: ltr; margin-left: 1em;">Regex</div>
 +
! <div style="text-align: left; direction: ltr; margin-left: 1em;">RadiMation Readout</div>
 +
! <div style="text-align: left; direction: ltr; margin-left: 1em;">Note</div>
 +
|-
 +
| U_L_N 325
 +
| <div style="text-align: right; direction: ltr; margin-left: 1em;">(-?[0-9.,Ee-]+)</div>
 +
| <div style="text-align: right; direction: ltr; margin-left: 1em;">325
 +
| <div style="text-align: left; direction: ltr; margin-left: 1em;">Takes the first number.</div>
 +
|-
 +
| I_L1;12.34
 +
| <div style="text-align: right; direction: ltr; margin-left: 1em;">;(-?[0-9.,Ee-]+)</div>
 +
| <div style="text-align: right; direction: ltr; margin-left: 1em;">12.34
 +
| <div style="text-align: left; direction: ltr; margin-left: 1em;">Takes the first number after ";".</div>
 +
|-
 +
| THD_U_L1;;14,5
 +
| <div style="text-align: right; direction: ltr; margin-left: 1em;">;;(-?[0-9.,Ee-]+)</div>
 +
| <div style="text-align: right; direction: ltr; margin-left: 1em;">14.5</div>
 +
| <div style="text-align: left; direction: ltr; margin-left: 1em;">Takes the first number after ";;".
 +
|-
 +
| AC_FREQ;Channel1;1.23E3
 +
| <div style="text-align: right; direction: ltr; margin-left: 1em;">;*;(-?[0-9.,Ee-]+)</div>
 +
| <div style="text-align: right; direction: ltr; margin-left: 1em;">1230</div>
 +
| <div style="text-align: left; direction: ltr; margin-left: 1em;">Takes the first number after the appearance of a second ";".
 +
|}
 +
 +
 +
Read backs can always be tested trough the "Validate Expression tool"
 +
<div style="text-align: left; direction: ltr; margin-left: 2em;">[[File:ValidateExpressionTool.png]]<\div>
 +
 +
[[Category:Configurable Drivers]]

Revision as of 12:24, 6 October 2016

Measuring data from the EUT using the Configurable AD Convertor device driver

This Application Note explains how RadiMation® can be configured to protect changes in the configuration by unqualified engineers.

Title of alinea 1

Text here


How to configure a Configurable AD Convertor

Configurable AD Converter Configuration Window.png

1 Specify the communication type

First the communication type must be configured.

ConfigureCommunication.png

2 Configure the initialization of the device

ScreenElementDescription.png Reset The reset code that needs to be send to device. When left blank no command will be send.
ScreenElementDescription.png Init The Init code that needs to be send to device. When left blank no command will be send.
ScreenElementDescription.png Get Id The code that needs to be send to device to get the identification back. A common used SCPI command is *IDN?. When left blank no command will be send.



3 Configure the data readout of the device

ScreenElementDescription.png Trigger and Reading
ScreenElementDescription.png Trigger The command need to trigger the measurement. A common used SCPI is *TRG. When left blank no command will be send.
ScreenElementDescription.png Read Back In the read back the returned information is defined. This is different for every type of machine there for RadiMation® used regular expressions to understand the format. A good regular expression for finding the first number in scientific notation in a text is:
([+-]?[0-9]*\.?[0-9]+([eE][+-]?[0-9]+)?)

For more possibilities see the example section

ScreenElementDescription.png Trigger and Reading
ScreenElementDescription.png Minimum value The lowest value that can be measured with this device. The value must be the same as filled in the EUT window.
ScreenElementDescription.png Maximum value The highest value that can be measured with this device. The value must be the same as filled in the EUT window.


4 Configure multiple channels for 1 device

Examples

Received information
Regex
RadiMation Readout
Note
U_L_N 325
(-?[0-9.,Ee-]+)
325
Takes the first number.
I_L1;12.34
;(-?[0-9.,Ee-]+)
12.34
Takes the first number after ";".
THD_U_L1;;14,5
;;(-?[0-9.,Ee-]+)
14.5
Takes the first number after ";;".
AC_FREQ;Channel1;1.23E3
;*;(-?[0-9.,Ee-]+)
1230
Takes the first number after the appearance of a second ";".


Read backs can always be tested trough the "Validate Expression tool"

ValidateExpressionTool.png<\div>