Performing an ETSI EN300328 MIMO measurement[edit]

This application note explains how a MIMO measurement can be performed with RadiMation® Free as it is described in the ETSI EN300328.

It is assumed that device drivers for the used powermeters are already configured in the configuration of RadiMation®. Otherwise see Device driver configuration in Chapter 2 of the RadiMation® Manual.

Create a new EUT-file by selecting from the menu bar:

   Menu.svg File
      Menu.svg New
         Menu.svg EUT

Specify a filename for the new EUT-file and select OK. A new EUT-window will now be opened.

To start the Burst measurement select from the menu bar:

   Menu.svg Tests
      Menu.svg Radiated Emission
         Menu.svg Burst

Press New to create a new TSF-file.   A new window will now be opened in which the test can be configured.

  • Press the + Add button to add all the power meters to your test.
  • Enter the correct parameters on the right hand side:
ScreenElementDescription.svg Frequency Different types of devices are available in RadiMation®. Only the created device drivers of the type that is selected for Device Driver Type will be shown in the list
ScreenElementDescription.svg Trigger level Shows a list of all the available device drivers for the selected Device Driver Type
ScreenElementDescription.svg etc..... Creates a new RadiMation® device driver for a specific device. It is only possible to create a new device driver for the selected Device Driver Type.


Press Start Test to start the measurement test with multiple power meters. Enter a filename to save the TSF-file, so it can be used again in the future.


  After a measurement has been performed, all parameter such as Max e.i.r.p, medium utilisation, Duty cycle, Min Gap time and Max. Sequence time and RMS are calculated by RadiMation®.