New pages
Jump to navigation
Jump to search
- 15:53, 21 November 2024 Release Notes/Solved items Version 2023.2.8 (hist | edit) [242 bytes] Roge (talk | contribs) (Created page with "== RadiMation version 2024.2.8 == * #15017: Check if the suggested RBW is a CISPR RBW in AUTO RBW receiver mode * #15273: Update documentation regarding the multiband VSWR test level * #15333: Printouts did not show graphs, this is fixed now.")
- 14:55, 21 November 2024 Release Notes/Solved items Version 2024.1.8 (hist | edit) [551 bytes] Roge (talk | contribs) (Created page with "== RadiMation version 2024.1.8 == * #15208: Don't send BAND:AUTO commands for the RS FSW * #15277: Update documentation regarding configuration of the serial number for Mini-Circuits GHS powermeters * #15290: SMCV100B Include password in lock command for firmware version 5.30 and higher * #15305: Add support for pulse modulated analysers as power meters * #15311: Printouts did not show graphs, this is fixed now. * #15333: Printouts did not show graphs, this is fixed now....")
- 11:32, 14 November 2024 RadiMation Application Note 161 (hist | edit) [8,611 bytes] Jeru (talk | contribs) (Created page with "== antenna spurious harmonics == ERP vs. EIRP: EIRP (Equivalent Isotropically Radiated Power): This is the power that would have to be radiated by an isotropic antenna (which radiates equally in all directions) to produce the same power density in a particular direction as the actual antenna. ERP (Effective Radiated Power): This is the power that would have to be radiated by a half-wave dipole antenna to achieve the same power density as the actual antenna in a particu...")
- 13:19, 11 November 2024 Testlevel calculated current limit (hist | edit) [1,616 bytes] Jeru (talk | contribs) (Created page with "==== Limit: calculated current ==== file:limit-calculated-current-testlevel.png")
- 13:19, 11 November 2024 Testlevel calculated voltage limit (hist | edit) [1,434 bytes] Jeru (talk | contribs) (Created page with "==== Limit: calculated voltage ==== file:limit-calculated-voltage-testlevel.png")
- 13:17, 11 November 2024 Testlevel voltage closed loop method (hist | edit) [841 bytes] Jeru (talk | contribs) (Created page with "==== Test level: voltage closed loop method ==== file:voltage-closed-loop-testlevel.png")
- 13:16, 11 November 2024 Testlevel voltage substitution method (hist | edit) [1,444 bytes] Jeru (talk | contribs) (Created page with "==== Test level: voltage substitution method ==== file:voltage-substitution-testlevel.png")
- 13:16, 11 November 2024 Testlevel current substitution method (hist | edit) [1,626 bytes] Jeru (talk | contribs) (Created page with "==== Test level: current substitution method ==== file:current-substitution-testlevel.png")
- 13:14, 11 November 2024 Testlevel current closed loop method (hist | edit) [698 bytes] Jeru (talk | contribs) (Created blank page)
- 12:45, 11 November 2024 Testlevel calculated magnetic field input (hist | edit) [1,861 bytes] Jeru (talk | contribs) (Created page with "=== Input: calculated magnetic field === file:Input-calculated-magnetic-field.png")
- 12:45, 11 November 2024 Testlevel magnetic field input (hist | edit) [862 bytes] Jeru (talk | contribs) (Created page with "=== Input: magnetic field === file:Input-magnetic-field.png")
- 12:44, 11 November 2024 Testlevel calculated voltage input (hist | edit) [1,424 bytes] Jeru (talk | contribs) (Created page with "=== Input: calculated voltage === file:Input-calculated-voltage.png")
- 12:43, 11 November 2024 Testlevel voltage measurement input (hist | edit) [825 bytes] Jeru (talk | contribs) (Created page with "=== Input: voltage measurement === file:Input-voltage-measurement.png")
- 12:43, 11 November 2024 Testlevel calculated current input (hist | edit) [1,606 bytes] Jeru (talk | contribs) (Created page with "=== Input: calculated current === file:Input-calculated-current.png")
- 12:43, 11 November 2024 Testlevel current sensor input (hist | edit) [672 bytes] Jeru (talk | contribs) (Created page with "=== Input: current sensor === file:Input-current-sensor.png")
- 12:42, 11 November 2024 Testlevel calculated electrical field calibration input (hist | edit) [1,485 bytes] Jeru (talk | contribs) (Created page with "=== Input: calculated electrical field calibration === file:Input-calculated-electrical-field-calibration.png")
- 12:41, 11 November 2024 Testlevel electrical field probe input (hist | edit) [998 bytes] Jeru (talk | contribs) (Created page with "=== Input: electrical field probe === file:Input-electrical-field-probe.png")
- 12:14, 11 November 2024 Testlevel calculated electrical field limit (hist | edit) [944 bytes] Jeru (talk | contribs) (Created page with "=== Limit Testlevel: calculated electrical field limit === file:Limit-calculated-electrical-field-testlevel.png")
- 12:13, 11 November 2024 Testlevel minimum performance limit (hist | edit) [414 bytes] Jeru (talk | contribs) (Created page with "=== Limit Testlevel: minimal performance limit === file:Limit-minimal-performance-testlevel.png") originally created as "Testlevel minimal performance limit"
- 12:13, 11 November 2024 Testlevel calculated magnetic field limit (hist | edit) [1,875 bytes] Jeru (talk | contribs) (Created page with "=== Limit Testlevel: calculated magnetic field limit === file:Limit-calculated-magnetic-field-testlevel.png")
- 12:12, 11 November 2024 Testlevel magnetic field limit (hist | edit) [877 bytes] Jeru (talk | contribs) (Created page with "=== Limit Testlevel: magnetic field limit === file:Limit-magnetic-field-testlevel.png")
- 12:12, 11 November 2024 Testlevel measured voltage limit (hist | edit) [826 bytes] Jeru (talk | contribs) (Created page with "=== Limit Testlevel: measured voltage limit === file:Limit-voltage-testlevel.png")
- 12:12, 11 November 2024 Testlevel measured current limit (hist | edit) [683 bytes] Jeru (talk | contribs) (Created page with "=== Limit Testlevel: measured current limit === file:Limit-current-testlevel.png")
- 12:11, 11 November 2024 Testlevel calculated electrical field calibration limit (hist | edit) [1,501 bytes] Jeru (talk | contribs) (Created page with "=== Limit Testlevel: calculated electrical field calibration limit === file:Limit-calculated-electrical-field-calibration-testlevel.png")
- 12:11, 11 November 2024 Testlevel measured electrical field limit (hist | edit) [1,003 bytes] Jeru (talk | contribs) (Created page with "=== Limit Testlevel: electrical field limit === file:Limit-electrical-field-testlevel.png")
- 12:10, 11 November 2024 Testlevel measured power limit (hist | edit) [1,128 bytes] Jeru (talk | contribs) (Created page with "=== Limit Testlevel: measured power limit === file:Limit-Power-testlevel.png")
- 11:47, 11 November 2024 Testlevel calculated electrical field method (hist | edit) [944 bytes] Jeru (talk | contribs) (Created page with "=== Test level: Calculated electrical field method === file:Calculated-electrical-field-testlevel.png")
- 11:36, 11 November 2024 Testlevel magnetic field substitution method (hist | edit) [1,880 bytes] Jeru (talk | contribs) (Created blank page)
- 11:36, 11 November 2024 Testlevel magnetic field closed loop method (hist | edit) [902 bytes] Jeru (talk | contribs) (Created blank page)
- 11:35, 11 November 2024 Testlevel electrical field closed loop method (hist | edit) [1,027 bytes] Jeru (talk | contribs) (Created blank page)
- 11:34, 11 November 2024 Testlevel electrical field substitution method (hist | edit) [1,481 bytes] Jeru (talk | contribs) (Created blank page) originally created as "Testlevel electrical field substitution"
- 11:27, 11 November 2024 Testlevel power testlevel (hist | edit) [1,141 bytes] Jeru (talk | contribs) (Created page with "file:TestLevel-Power-testlevel.png")
- 11:26, 11 November 2024 Testlevel power input (hist | edit) [1,113 bytes] Jeru (talk | contribs) (Created page with "file:TestLevel-Power-input.png") originally created as "Testlevel-power"
- 10:47, 11 November 2024 Multiband testlevels (hist | edit) [3,024 bytes] Jeru (talk | contribs) (Created page with "=== Test levels === In RadiMation’s MultiBand testing modules, "test levels" are settings that control how power is regulated, limited, and measured during EMC testing. They play a crucial role in ensuring that devices under test are exposed to consistent and precise levels across multiple frequency bands. Here’s how test levels work and how they affect your testing process in RadiMation: ==== Types of Test Levels ==== In RadiMation’s MultiBand modules, there ar...")
- 10:44, 11 November 2024 Testlevel VSWR (hist | edit) [1,519 bytes] Jeru (talk | contribs) (Created page with "==== Input Test level: VSWR ==== The VSWR (Voltage Standing Wave Ratio) test level in RadiMation is a measurement that indicates how well the energy from a signal source is being transferred to a device under test. It provides insight into the efficiency of power delivery, with a lower VSWR indicating better efficiency and minimal energy reflection. This is important in electromagnetic immunity testing to ensure accurate power application across test frequencies. In Ra...") originally created as "Testlevel-VSWR"
- 10:42, 11 November 2024 Multiband-conducted-immunity-testlevels (hist | edit) [1,091 bytes] Jeru (talk | contribs) (Created blank page)
- 10:42, 11 November 2024 Multiband-radiated-immunity-testlevels (hist | edit) [1,201 bytes] Jeru (talk | contribs) (Created blank page)
- 09:50, 11 November 2024 Mini-ciruits-configuration (hist | edit) [713 bytes] Jeru (talk | contribs) (Created page with "= Configuration = To use the power meter the serial number needs to be configured. # Find the serial number of the power meter. # Start RadiMation # Go to: Configuration > Configuration > Device drivers > Powermeters # Select the PWR-SEN-6GHS device driver, and press on 'Edit'. # Press the 'Shift' key on the keyboard and keep it pressed while you click with the mouse on the 'Advanced' button. # A Notepad window will appear. Find the part that shows something like: [...")
- 10:58, 7 November 2024 Release Notes/Solved items Version 2024.1.7 (hist | edit) [2,009 bytes] Jeru (talk | contribs) (Created page with "== RadiMation version 2024.1.7 == * #14719: Fix switching of the R&S OSP * #14794: Data files and TSF files from 2020.0.x can be opened again. * #15095: Driver: Haefely AXOS 5 * #15103: Add reseller: Altoo * #15106: RadiMation force closes when setting up GPIB connection to Keithley DMM7510 * #15137: Frankonia FPD-REM is now controlled using a single command byte * #15138: Frankonia RSU: No mutex error is raised anymore * #15139: Check of Frankonia VLH 500B1 amp...")
- 10:57, 7 November 2024 Release Notes/Solved items Version 2023.2.7 (hist | edit) [5,424 bytes] Jeru (talk | contribs) (Created page with "== RadiMation version 2023.2.7 == * #13571: Driver: Keithley DMM7510 * #13771: Driver: Agilent DSO9104A * #13865: Prevent DMM6500 from showing error -102 during measurement * #13911: TDEMI ULTRA changed RBW from 1 kHz to 120 kHz * #13911: TDEMI add MIL suffix to command when selecting MIL and DO RBW values * #14605: Clearing the time-out error resulting by an EP600 results in an infinite retry loop * #14385: Driver: Ceyear Technologies 87235H powermeter * #14394...")
- 13:34, 28 October 2024 RadiMation Error: 805784369 (hist | edit) [523 bytes] Roge (talk | contribs) (Created page with "= The expected switch state 'expected state' is not switched correctly. The actual state of the RSU is 'actual state' = The {{RadiMation}} driver sends the expected switch state to the RSU device and then checks if the state corresponds to the expected state. When the actual state differs from the expected, {{RadiMation}} raises an error. == Solution == * Reboot the Frankonia RSU switch unit. * Contact {{RadiMation}} support and send in an error report. Category:Radi...")
- 16:40, 5 October 2024 Terminology (hist | edit) [5,789 bytes] Joro (talk | contribs) (Created page with ";CDN :Coupling/Decoupling Network ;CE :Conducted Emission :Conformité Européenne - Complying to European regulations ;LISN :Line Impedance Stabilisation Network")
- 18:35, 1 October 2024 RohdeSchwarzNRPZSeriesPowermeters (hist | edit) [4,340 bytes] Joro (talk | contribs) (Created page with "<noinclude>{{Note|This page is used to show the configuration that is generic for all Rohde & Schwarz NRP Zxx-Series powermeter device drivers. This page can now easily be embedded on all relevant device driver pages.}}</noinclude> The {{PAGENAME}} is a power meter with a diode head connected by USB to the PC. = Notes = * The {{RadiMation}} device driver can only be used if the program NRPView, 1.0.27 or above, from Rohde & Schwarz is installed. When installing...")
- 18:51, 29 September 2024 Ticket database (hist | edit) [26 bytes] Joro (talk | contribs) (Redirected page to Error Report) Tag: New redirect
- 17:58, 29 September 2024 Release Notes (hist | edit) [37 bytes] Joro (talk | contribs) (Created page with "#REDIRECT [[Release Notes {{LatestMajorMinorVersion}}]]")
- 15:04, 26 September 2024 Release Notes/Drivers Version 2024.09.26.1702 (hist | edit) [130 bytes] DevicesBot (talk | contribs) (Initial Release_Notes/Drivers_Version_2024.09.26.1702 page creation)
- 10:19, 26 September 2024 Release Notes/Drivers Version 2024.09.26.1158 (hist | edit) [188 bytes] DevicesBot (talk | contribs) (Initial Release_Notes/Drivers_Version_2024.09.26.1158 page creation)
- 07:46, 25 September 2024 Release Notes/Solved items Version 2024.1.6 (hist | edit) [1,137 bytes] Jeru (talk | contribs) (Created page with "== RadiMation version 2024.1.6 == * #15133: Software protection key error without valid license * #15132: License key is sometimes detected as Essential even though it is a Pr...")
- 01:06, 25 September 2024 PONTIS Pecos 7 EUTController (hist | edit) [161 bytes] DevicesBot (talk | contribs) (Initial DeviceDriverInfo page creation)
- 01:06, 25 September 2024 PONTIS Pecos 7 ADConverter (hist | edit) [152 bytes] DevicesBot (talk | contribs) (Initial DeviceDriverInfo page creation)