- 11:27, 21 March 2025 Release Notes 2025.1 (hist | edit) [798 bytes] Roge (talk | contribs) (Created page with "__NOTOC__ {{:WarningLatestVersion}} = Introduction = We are proud to deliver you Version 2025.1 of our {{RadiMation}} EMC Test software. This 2024.2 version is the result of several major improvements that we have done. This letter contains all the information that is needed before your system is upgraded. If you have any additional questions or remarks please let us know through your reseller, or contact {{MailSupport}}. {{...")
- 11:16, 21 March 2025 Release Notes/Solved items Version 2025.1 (hist | edit) [48 bytes] Roge (talk | contribs) (Created page with "{{:Release Notes/Solved items Version 2025.1.1}}")
- 11:15, 21 March 2025 Release Notes/Solved items Version 2025.1.1 (hist | edit) [1,064 bytes] Roge (talk | contribs) (Created page with "== RadiMation version 2025.1.1 == * #9490: Double clicking on the name of a graph element in the legend of a multiband graph shows the graph customization for the element * #10299: A minimum RBW of 1 Hz can now be selected * #13086: The reveal buttons (with a magnifying glass symbol) in the list of correction files for a device driver now correctly show as enabled when a file is selected. * #13774: Correction files can be dragged to the correction file list of the device...")
- 09:29, 21 March 2025 Release Notes/Solved items Version 2024.1.10 (hist | edit) [581 bytes] Roge (talk | contribs) (Created page with "== RadiMation version 2024.1.10 == * #13537: When saving files fewer intermediate temporary files are created and then deleted again. * #14555: Improved R&S NRT configuration screen and added option checking * #15491: Fix rotate maturo turntable from 0 to 360 degrees * #15665: The 'Save as' menu for a new TSF file now loads much faster when there are many directories and files. * #15690: Configurable EUT controller now replaces the correct __polarisation__ value * #1571...")
- 10:32, 13 March 2025 Emission.RBW.Values (hist | edit) [456 bytes] Joro (talk | contribs) (Created page with "This advanced option specifies a ';' seperated list of RBW values expressed in kHz, that are listed in the dropdown box of the RBW in the TSF window. There are other advanced options available that determine the other limitations of the number of detectable peaks * Emission.RBW.Min * Emission.RBW.Max * Emission.RBW.Default * Emission.RBW.Values * Emission.RBW.Step {{AdvancedOption}} Category:RadiMation")
- 10:31, 13 March 2025 Emission.RBW.Step (hist | edit) [542 bytes] Joro (talk | contribs) (Created page with "This advanced option specifies the increment and decrement of the selected RBW expressed in kHz in the TSF window, if the up or down buttons are used. The default value is 1, corresponding to a 1 kHz increment or decrement of the RBW. There are other advanced options available that determine the other limitations of the number of detectable peaks * Emission.RBW.Min * Emission.RBW.Max * Emission.RBW.Default * Emission.RBW.Valu...")
- 10:29, 13 March 2025 Emission.RBW.Default (hist | edit) [472 bytes] Joro (talk | contribs) (Created page with "This advanced option specifies the default value (expressed in kHz) for the RBW value that can be selected. The default value is 120, corresponding to a 120 kHz RBW. There are other advanced options available that determine the other limitations of the number of detectable peaks * Emission.RBW.Min * Emission.RBW.Max * Emission.RBW.Default * Emission.RBW.Values * Emission.RBW.Step {{AdvancedOption}} Category:RadiMation")
- 10:29, 13 March 2025 Emission.RBW.Max (hist | edit) [473 bytes] Joro (talk | contribs) (Created page with "This advanced option specifies the maximum value (expressed in kHz) for the RBW value that can be selected. The default value is 50000, corresponding to a 50 MHz RBW. There are other advanced options available that determine the other limitations of the number of detectable peaks * Emission.RBW.Min * Emission.RBW.Max * Emission.RBW.Default * Emission.RBW.Values * Emission.RBW.Step {{AdvancedOption}} Category:RadiMati...")
- 10:28, 13 March 2025 Emission.RBW.Min (hist | edit) [471 bytes] Joro (talk | contribs) (Created page with "This advanced option specifies the minimum value (expressed in kHz) for the minimum RBW value that can be selected. The default value is 0.001, corresponding to a 1 Hz RBW. There are other advanced options available that determine the other limitations of the number of detectable peaks * Emission.RBW.Min * Emission.RBW.Max * Emission.RBW.Default * Emission.RBW.Values * Emission.RBW.Step {{AdvancedOption}} Category:Ra...")
- 14:54, 5 March 2025 DeviceDriverPreselectorTab (hist | edit) [377 bytes] Joro (talk | contribs) (Created page with "Image:DeviceDriverPreselector.png On the {{ScreenElement|Preselector}} tab, it can be selected if the preselector should be activated or not deactivated when the device driver of the {{PAGENAME}} is being used. {{ScreenElementDescriptionStart}} {{ScreenElementDescription|Enable preselector|If the preselector should be activated, or not.}} {{ScreenElementDescriptionEnd}}")
- 16:30, 25 February 2025 RadiMation Application Note 164 (hist | edit) [8,667 bytes] Roge (talk | contribs) (Created page with "__NOTOC__ == How to perform a MIL-STD-461 CS101, Conducted susceptibility, power leads == This application note explains how the MIL-STD-461 CS101, Conducted susceptibility, power leads test can be performed with {{RadiMation}} CS101 is a test method used in military and aerospace environments to assess the conducted susceptibility of equipment to low-frequency interference, 30 Hz - 150 kHz, ensuring it operates reliably in the presence of conducted disturbances. The e...")
- 10:02, 24 February 2025 UI.Graphs.Highlight.Thickness (hist | edit) [356 bytes] Naka (talk | contribs) (Add page)
- 09:59, 24 February 2025 UI.Graphs.Highlight.Transparency (hist | edit) [404 bytes] Naka (talk | contribs) (Add UI.Graphs.Highlight.Transparency page)
- 09:37, 24 February 2025 Release Notes/Solved items Version 2024.2.3 (hist | edit) [1,038 bytes] Jeru (talk | contribs) (Created page with "== RadiMation version 2024.2.3 == * #14602: Driver: Netatmo module, to retrieve temperature, humidity and pressure from Netatmo devices * #15286: Fixed an issue where opening test results could hang due to a deadlock * #15500: Pevent that MatchesString causes a crash in Microsoft - STL - xmemory * #15502: Improved stability when multiple RadiSense devices are controlled in parallel * #15528: Cryptographic library updated to latest version * #15564: Improved automatic re...")
- 13:14, 19 February 2025 RadiMation Error: 805317373 (hist | edit) [412 bytes] Roge (talk | contribs) (Created page with "= To use the RS SMR below 1 GHz, option B11 is required, adjust the start frequency to 1 GHz in the device driver advanced settings to use this driver without option B11 = To use the RS SMR below 1 GHz, option B11 is required == Solution == * adjust the start frequency to 1 GHz in the device driver advanced settings to use this driver without option B11. Category:RadiMation Error Category:RadiMation")
- 13:49, 24 January 2025 RadiMation Application Note 163 (hist | edit) [5,225 bytes] Joro (talk | contribs) (Created page with "__NOTOC__ == Automatically Retrieve and Log the Operating Mode of the Tested EUT == In EMC testing, it is sometimes necessary to check and document specific information about the Equipment Under Test (EUT), such as its operating mode, model number, firmware version, or activated options. RadiMation includes a 'General test information retriever' device driver, classified as an 'EUT controller' device driver, which can be configured to automatically retrieve this informat...")
- 14:57, 23 January 2025 Release Notes/Solved items Version 2024.2.2 (hist | edit) [385 bytes] Joro (talk | contribs) (Created page with "== RadiMation version 2024.2.2 == * #15485: Customized printout template with extension other than word documents are working again * #15503: Multiple report generator codes with digit only content are not converted into a single numeric value in Microsoft Excel anymore * #15531: If skip unknown mainkeywords is activated, a known and available test is not detected as unknown anymore")