New pages
Jump to navigation
Jump to search
- 12:38, 4 December 2025 Auxiliary equipment (hist | edit) [968 bytes] Voko (talk | contribs) (Created page with "Auxiliary Equipment represents supporting components that are part of the EMC test setup, but do not fall under any of the dedicated device driver categories. These items may not play an active role in controlling or measuring signals, yet they are relevant for defining a complete and traceable test environment. This device type is intended for equipment such as tables, fixtures, computers, mechanical accessories, simple auxiliary mechanisms, or any other elements that...")
- 08:27, 4 December 2025 Release Notes/Solved items Version 2025.1.5 (hist | edit) [2,259 bytes] Roge (talk | contribs) (Created page with "== RadiMation version 2025.1.5 == * #15505: Milmega: automatically detect which controller AC-001 or AC-002 is used * #16015: Added R&S BBA150 DDC25 couplers * #16066: Signal power graph is now available when a multiband closed loop field test level is used * #16129: Display a warning in the event log of a test if the measurement is not within the 'max difference' after the 'max measure' measurements * #16147: Driver: COM-POWER CLCI-400 * #16148: Driver: COM-POWER FCLC-...")
- 15:02, 3 December 2025 Release Notes/Solved items Version 2024.2.7 (hist | edit) [3,266 bytes] Roge (talk | contribs) (Created page with "== RadiMation version 2024.2.7 == * #12918: When pressing retry perform a full device driver check * #14893: Driver: Exodus AMP2070A * #14894: Driver: Exodus AMP2071A * #15414: Driver: Rohde & Schwarz UPV * #15626: Re-activate write termination to use implicit GPIB EOI * #15670: R&S FPC1500 driver improvements * #15897: Add hidden member to allow selection of DC high impedance coupling * #15994: Fix Attachment is not included in report with ||EUT|ATTACHMENT 1 CONTENTS||...")
- 08:56, 25 November 2025 RadiMation Application Note 168 (hist | edit) [3,578 bytes] Voko (talk | contribs) (Created page with "= EUT Attachments in RadiMation® = {{Note|These features are available starting from RadiMation 2025.2.1}} === Overview and Use Cases of EUT Attachments === The EUT Attachments feature allows to store additional files '''inside''' the .EUT file. This makes the EUT fully self-contained, portable and independent from the PC file structure. When a .EUT file is moved to another workstation, all embedded attachments are included. Attachments are useful for storing: * phot...")
- 11:21, 18 November 2025 BBAConfiguration (hist | edit) [258 bytes] Roge (talk | contribs) (Created page with "{{:DeviceDriverCommunicationTab}}")
- 15:51, 31 October 2025 RadiMation Application Note 167 (hist | edit) [6,200 bytes] Joro (talk | contribs) (Created page with "__NOTOC__ = Controlling a custom Arduino relay device via the Configurable Switch Matrix driver = This application note explains how a user-made Arduino device that controls a relay can be operated directly from {{RadiMation}} by using the Configurable Switch Matrix device driver. By configuring the correct serial communication and defining the proper commands, it is possible to automatically switch between a low-frequency and a high-frequency amplifier within the...")
- 12:48, 31 October 2025 RadiMation Error: 805354071 (hist | edit) [369 bytes] Jeru (talk | contribs) (Created page with "= The movement to the requested position did not start. = The movement requested from the positioner did not start. == Solution == * Check if nothing is blocking the movement of the device. * Check if additional requirements in order to control the device are met. Such as for example referencing the positioner. Category:RadiMation Error Category:RadiMation")
- 12:47, 31 October 2025 RadiMation Error: 805373169 (hist | edit) [373 bytes] Jeru (talk | contribs) (Created page with "= The movement to the requested height did not start. = The movement requested from the antenna tower did not start. == Solution == * Check if nothing is blocking the movement of the device. * Check if additional requirements in order to control the device are met. Such as for example referencing the antenna tower. Category:RadiMation Error Category:RadiMation")
- 12:46, 31 October 2025 RadiMation Error: 805373269 (hist | edit) [363 bytes] Jeru (talk | contribs) (Created page with "= The movement to the requested position did not start = The movement requested from the positioner did not start. == Solution == * Check if nothing is blocking the movement of the device. * Check if additional requirements in order to control the device are met. Such as for example referencing the positioner. Category:RadiMation Error Category:RadiMation")
- 11:42, 31 October 2025 AIM 7351731 (hist | edit) [4,239 bytes] Joro (talk | contribs) (Created page with "__NOTOC__ = AIM 7351731 = == Scope and Purpose == The AIM 7351731 standard provides test methods and test levels for evaluating the electromagnetic immunity of (non-implantable) medical electrical equipment and systems when exposed to electromagnetic emissions from radio-frequency identification (RFID) readers. The standard focuses on the most common RFID technologies currently deployed in health...")
- 11:13, 28 October 2025 RadiMation Application Note 166 (hist | edit) [7,031 bytes] Joro (talk | contribs) (Created page with "= RadiMation Application Note 139: Radiated Emission GTEM Measurement = == Introduction == This application note describes how a radiated emission test can be performed in a GTEM (Gigahertz Transverse Electromagnetic) cell using the {{RadiMation}} software. It explains the practical configuration steps in {{RadiMation}}, and also the basic theory behind the GTEM concept and the OATS (Open Area Test Site) correlation. Radiated emission testing is normally performed...")
- 10:21, 7 October 2025 RadiMation Error: 805372575 (hist | edit) [578 bytes] Voko (talk | contribs) (Created page with "= Netatmo Environmental Data Provider: Environmental Limits Error = '''Netatmo environmental data provider:''' The measured value of pressure is higher than the configured maximum environmental limit. This error indicates that the measured pressure value from the Netatmo environmental sensor exceeds the configured maximum environmental limit. == Configuration == This setting can be verified or adjusted in the device driver '''Advanced''' configuration dialog: ''Envi...")
- 10:20, 7 October 2025 RadiMation Error: 805372576 (hist | edit) [579 bytes] Voko (talk | contribs) (Created page with "= Netatmo Environmental Data Provider: Environmental Limits Error = '''Netatmo environmental data provider:''' The measured value of pressure is lower than the configured minimum environmental limit. This error indicates that the measured pressure value from the Netatmo environmental sensor is below the configured minimum environmental limit. == Configuration == This setting can be verified or adjusted in the device driver '''Advanced''' configuration dialog: ''Envi...")
- 10:19, 7 October 2025 RadiMation Error: 805372571 (hist | edit) [578 bytes] Voko (talk | contribs) (Created page with "= Netatmo Environmental Data Provider: Environmental Limits Error = '''Netatmo environmental data provider:''' The measured value of humidity is higher than the configured maximum environmental limit. This error indicates that the measured humidity value from the Netatmo environmental sensor exceeds the configured maximum environmental limit. == Configuration == This setting can be verified or adjusted in the device driver '''Advanced''' configuration dialog: ''Envi...")
- 10:18, 7 October 2025 RadiMation Error: 805372572 (hist | edit) [579 bytes] Voko (talk | contribs) (Created page with "= Netatmo Environmental Data Provider: Environmental Limits Error = '''Netatmo environmental data provider:''' The measured value of humidity is lower than the configured minimum environmental limit. This error indicates that the measured humidity value from the Netatmo environmental sensor is below the configured minimum environmental limit. == Configuration == This setting can be verified or adjusted in the device driver '''Advanced''' configuration dialog: ''Envi...")
- 10:17, 7 October 2025 RadiMation Error: 805372574 (hist | edit) [597 bytes] Voko (talk | contribs) (Created page with "= Netatmo Environmental Data Provider: Environmental Limits Error = '''Netatmo environmental data provider:''' The measured value of temperature is lower than the configured minimum environmental limit. This error indicates that the measured temperature value from the Netatmo environmental sensor is below the configured minimum environmental limit. == Configuration == This setting can be verified or adjusted in the device driver '''Advanced''' configuration dialog:...")
- 10:13, 7 October 2025 RadiMation Error: 805372573 (hist | edit) [606 bytes] Voko (talk | contribs) (Created page with "= Netatmo Environmental Data Provider: Environmental Limits Error = '''Netatmo environmental data provider:''' The measured value of temperature is higher than the configured maximum environmental limit. This error indicates that the measured temperature value from the Netatmo environmental sensor exceeds the configured maximum environmental limit. == Configuration == This setting can be verified or adjusted in the device driver '''Advanced''' configuration dialog:...")
- 13:39, 1 October 2025 Release Notes/Solved items Version 2025.1.4 (hist | edit) [798 bytes] Jeru (talk | contribs) (Created page with "== RadiMation version x.y.z == * #8655: GTEM correlation graph is now also shown when an ambient suppression line is present * #9118: GTEM correlation is now also calculated when ambient suppression is present in multiband emission GTEM test * #10837: Multiband GTEM is now quicker as x y z position has not to be rotated many times * #15027: Final measurement of GTEM Peaks is optimised to measure all frequencies of a given axis first * #15258: Placing of the EUT in the GT...")
- 13:42, 19 September 2025 UI.Graphs.Highlight.BringToFront (hist | edit) [498 bytes] Naka (talk | contribs) (Create page for Creating UI.Graphs.Highlight.BringToFront)
- 15:45, 16 September 2025 Release Notes/Solved items Version 2025.1.3 (hist | edit) [2,331 bytes] Jeru (talk | contribs) (Created page with "* #7078: Dialogs are now always shown on the same screen where RadiMation is open * #12906: Newly added rows to the correction file will contain the next logical frequency * #16111: Improvements relation the correction file UI * #16168: Remove the initial row from the correction file when data is pasted * #16176: The position of the external RadiMation windows is saved and restored the next time they are opened * #16194: Always display newly opened windows fully within t...")
- 12:33, 10 September 2025 RadiMation Error: 805351476 (hist | edit) [531 bytes] Joro (talk | contribs) (Created page with "= The Average detector can only be used if it is the only active detector. Disable other detectors = For the Rohde & Schwarz spectrum analyser, multiple trace detectors are activated, one of them being the average detector. The average detector can however only be used during the prescan if it is the only detector. == Solution == * Disable the average detector during the prescan. * Disable all the other detectors (and only enable the average detector) during the prescan...")
- 13:16, 9 September 2025 RadiMation Application Note 165 (hist | edit) [9,933 bytes] Roge (talk | contribs) (Created page with "__NOTOC__ == How to perform a IEC 61000-4-6, Conducted immunity test == This application note explains how the IEC 61000-4-6 conducted immunity test can be performed with {{RadiMation}}. The IEC 61000-4-6 conducted immunity test method is used for electrical and electronic equipment that may be subjected to radio-frequency disturbances conducted along cables coming from radio transmitters in the frequency range from 150 kHz up to 80 MHz. The exact requirements, calibrati...")
- 12:55, 8 September 2025 Font specification in an advanced option without color (hist | edit) [774 bytes] Joro (talk | contribs) (Created page with "<noinclude>{{Note|This page is only available to be included in another page, to give a more detailed description of the format that is allowed for the specification of the font in an advanced option}}{{Note|Also see the Font specification in an advanced option page which does specify something very similor, but including the color}}</noinclude> This advanced option allows the specification of a font and it characteristics in the following format: <FONT NAME>...")