User contributions for Joro

Jump to navigation Jump to search
Search for contributionsExpandCollapse
⧼contribs-top⧽
⧼contribs-date⧽
(newest | oldest) View ( | ) (20 | 50 | 100 | 250 | 500)

13 February 2020

  • 15:2415:24, 13 February 2020 diff hist −157 GAUSS INSTRUMENTS TDEMINo edit summary
  • 11:3411:34, 13 February 2020 diff hist +418 N RadiMation Error: 805322380Created page with "= Different frequency step sizes are used by different detectors = Two or more traces are selected to be measured simultaneously, however it is detected that the step frequenc..." current
  • 11:0811:08, 13 February 2020 diff hist +802 N RadiMation Error: 805322379Created page with "= Unable to set the scan measure time. Probably is measure time too short, increase the measure time value. Minimum scan measure time seems to be <MINIMUM> ms. = A measure tim..."
  • 11:0411:04, 13 February 2020 diff hist +462 N RadiMation Error: 805322378Created page with "= Preamplifier option is not present in this TDEMI. set preamplifier to 0 dB = It is detected that the TDEMI doesn't have the Preamplifier option installed. It is thus not pos..." current
  • 11:0111:01, 13 February 2020 diff hist +376 N RadiMation Error: 805322377Created page with "= The number of use-able detectors in receiver mode is limited to <NUMBER> = The number of simultaneously usable detectors in the TDEMI in receiver mode is limited to '<NUMBER..." current
  • 11:0011:00, 13 February 2020 diff hist +381 N RadiMation Error: 805322376Created page with "= The number of use-able detectors in spectrogram mode is limited to <NUMBER> = The number of simultaneously usable detectors in the TDEMI in spectogram mode is limited to '<N..." current
  • 10:5910:59, 13 February 2020 diff hist +495 N RadiMation Error: 805322375Created page with "= The TDEMI has changed the selected frequency range. Select a frequency range that is supported by the TDEMI = Due to TDEMI specific limitations, the desired frequency range..." current
  • 10:5510:55, 13 February 2020 diff hist +459 N RadiMation Error: 805322374Created page with "= RMS detector can only be used on first trace. RMS on second trace is not possible = The TDEMI is not able to use the RMS detector on a second trace. The configuration of the..." current
  • 10:5310:53, 13 February 2020 diff hist +516 N RadiMation Error: 805322373Created page with "= Actual resolution of the TDEMI cannot be determined = The resolution specifies the number of points that are present in a measured trace. The TDEMI device driver is unable..." current
  • 10:5210:52, 13 February 2020 diff hist +438 N RadiMation Error: 805322372Created page with "= No TDEMI State is available at this moment. = The data maintainer class that is used to maintain the state information of the TDEMI is not available. This is an internal de..." current
  • 10:5010:50, 13 February 2020 diff hist +430 N RadiMation Error: 805322371Created page with "= No TDEMICommunication instance is available at this moment = The communication class that is used to communicate with TDEMI is not available. This is an internal device dri..." current
  • 10:4610:46, 13 February 2020 diff hist +471 N RadiMation Error: 805322370Created page with "= TDEMI version is below 5.20 and thus the preamplifier is not supported = It is detected that the firmware version of the TDEMI is below 5.20. In these older firmware version..." current
  • 10:4510:45, 13 February 2020 diff hist +359 N RadiMation Error: 805322369Created page with "= TDEMI version is below 1.28d and thus zero-span mode is not supported = It is detected that the firmware version of the TDEMI is below 1.28. In these older firmware versions..." current
  • 10:4310:43, 13 February 2020 diff hist +472 N RadiMation Error: 805322368Created page with "= The LISN Phase '<PHASE>' could not be selected in the TDEMI. Currently selected phase: '<OTHER PHASE>' = It was requested to select the <PHASE> of the LISN that is connected..." current