The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
To structure the different levels of experience with RadiMation, we created an experience level matrix:
|
Novice
|
Competent
|
Master
|
Expert
|
General
|
- Able to create a new EUT file
- Able to start an existing TSF
- Able to enter / modify notes
- Able to view test data
- Able to start a sequence
|
- Able to create / modify a TSF
- Able to specify Monitoring inputs
- Able to create / modify Correction files
- Able to create / modify a sequence
- Able to retrieve customer information from another database
- Able to change / add information items
|
- Able to use overlapping bands in a Multiband test
- Able to optimize the change order in Multiband tests
- Able to export graphs and data to other software programs
- Able to use TSF file protection and user rights permissions
|
|
Radiated Immunity
|
|
- Able to perform a calibration
- Able to perform a 16 point UFA calculation
- Aware of different modulation types
|
- Able to use multiple test-levels and limits
- Able to perform minimum performance testing
|
- Able to evaluate and improve total test time
|
Conducted Immunity
|
|
- Able to perform a calibration
- Aware of different modulation types
|
- Able to use multiple test-levels and limits
- Able to perform minimum performance testing
|
- Able to evaluate and improve total test time
|
Pulsed Immunity
|
|
|
|
|
Radiated Emission
|
|
- Able to create / modify limit lines
- Aware of receiver settings and consequences
|
|
|
Conducted Emission
|
|
- Able to create / modify limit lines
- Aware of receiver settings and consequences
|
- Able to use continuous measurement
- Able to use graph comparisons between multiple tests
|
|
Report Generator
|
- Able to generate a report from an existing template
|
|
- Able to use virtual test names in report generator templates
- Able to use test specific templates
- Able to use the ||IncludeFile(...)|| code
- Able to use ||StartDeleteBlock()|| and ||EndDeleteBlock()|| codes
|
|
Configuration / Installation
|
- Able to check if a device is connected
|
- Able to install RadiMation on a PC
- Able to update device drivers
- Able to create and configure testsites
- Able to add / modify test engineers
|
- Able to configure RadiMation® for usage on a network
- Able to add actions to a testsite
- Able to configure a customer database interface
- Able to configure basic standards and product standards
|
|
Measurement equipment
|
|
- Able to add and configure device drivers for measurement equipment
- Aware of diffences between spectrum analyzer / scanning receiver / receiver
|
- Able to create NI-SPY files
- Able to optimize powermeter and field sensor monitoring settings
- Able to configure automatically controlled LISN's
- Able to configure switch matrixes
- Able to apply corrections to the measurement equipment
|
- Able to use configurable device drivers to control equipment
|
RadiMation® Free
|
- Able to connect to devices and perform measurements
|
|
|
|