Experience Levels: Difference between revisions

From RadiWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 19: Line 19:
* Able to specify Monitoring inputs
* Able to specify Monitoring inputs
* Able to create / modify Correction files
* Able to create / modify Correction files
* Able to create / modify a sequence
* [[Chapter 11#Creating and saving a sequence|  Able to create / modify a sequence]]
* Able to retrieve customer information from another database
* Able to retrieve customer information from another database
* Able to change / add information items
* Able to change / add information items

Revision as of 08:21, 3 December 2014

To structure the different levels of experience with RadiMation, we created an experience level matrix:

Novice Competent Master Expert
General
  • Able to create a new EUT file
  • Able to start an existing TSF
  • Able to enter / modify notes
  • Able to view test data
  • Able to start a sequence
  • Able to create / modify a TSF
  • Able to specify Monitoring inputs
  • Able to create / modify Correction files
  • Able to create / modify a sequence
  • Able to retrieve customer information from another database
  • Able to change / add information items
  • Able to use overlapping bands in a Multiband test
  • Able to optimize the change order in Multiband tests
  • Able to export graphs and data to other software programs
  • Able to use TSF file protection and user rights permissions
Radiated Immunity
  • Able to perform a calibration
  • Able to perform a 16 point UFA calculation
  • Aware of different modulation types
  • Able to use multiple test-levels and limits
  • Able to perform minimum performance testing
  • Able to evaluate and improve total test time
Conducted Immunity
  • Able to perform a calibration
  • Aware of different modulation types
  • Able to use multiple test-levels and limits
  • Able to perform minimum performance testing
  • Able to evaluate and improve total test time
Pulsed Immunity
Radiated Emission
  • Able to create / modify limit lines
  • Aware of receiver settings and consequences
Conducted Emission
  • Able to create / modify limit lines
  • Aware of receiver settings and consequences
  • Able to use continuous measurement
  • Able to use graph comparisons between multiple tests
Report Generator
  • Able to generate a report from an existing template
  • Able to use virtual test names in report generator templates
  • Able to use test specific templates
  • Able to use the ||IncludeFile(...)|| code
  • Able to use ||StartDeleteBlock()|| and ||EndDeleteBlock()|| codes
Configuration / Installation
  • Able to check if a device is connected
  • Able to install RadiMation on a PC
  • Able to update device drivers
  • Able to create and configure testsites
  • Able to add / modify test engineers
  • Able to configure RadiMation® for usage on a network
  • Able to add actions to a testsite
  • Able to configure a customer database interface
  • Able to configure basic standards and product standards
Measurement equipment
  • Able to add and configure device drivers for measurement equipment
  • Aware of diffences between spectrum analyzer / scanning receiver / receiver
  • Able to create NI-SPY files
  • Able to optimize powermeter and field sensor monitoring settings
  • Able to configure automatically controlled LISN's
  • Able to configure switch matrixes
  • Able to apply corrections to the measurement equipment
  • Able to use configurable device drivers to control equipment
RadiMation® Free
  • Able to connect to devices and perform measurements