FAQ
This page contains all the Frequently Asked Questions related the general usage of RadiMation®
How can I overlap two graphs in multi band?[edit]
To overlap two graphs, open both the test results. In one of the two test results press the graphs button. you will see that the other test is available for selection. You can add any line from the other test result into the current graph.
Creating a pause in a multi-band test[edit]
There is no real pause inside multi band, but in general the only time you need a pause is when changing the test set up. For this you can use the before and after action in the test set up.
How can I reset the administrator password in RadiMation®?[edit]
The password of the administrator cannot be cleared, it is however possible to remove the administrator account. If RadiMation® is started without an Administrator account, RadiMation® will automatically create a new Administrator account with the default RadiMation® password.
Use the following steps to remove the Administrator account:
- Close RadiMation® before continuing.
- In the RadiMation® CONFDVDR folder (most often: C:\Program Files\DARE Development\RadiMation\CONFDVDR\) the file SETTINGS.INI is present. Open this file, and search for the keyword [Engineers]. After this line, search for the engineer that is named Administrator. (for example: Engineer1=Administrator).
- Remove all the lines that start with: Engineer<NR>, where the <NR> is the same number (in the example: 1) as the number of the engineer that was named Administrator.
- Save the file and start RadiMation®.
What is the default RadiMation® password for the Administrator?[edit]
The default password for the administrator is: Radimation
What are the minimum PC requirements?[edit]
The minimum PC requirements are described in Chapter 2 of the manual
Where can I read the latest developments in RadiMation®?[edit]
The current development status page is regularly updated with the latest improvements to RadiMation®.
How can I see which pages have been changed recently?[edit]
This RadiWiki site is using the MediaWiki software that is also used by Wikipedia. Most of the features that are present on Wikipedia, are thus also present on this RadiWiki site. Some possibilities to monitor recent changes are:
- Use the Recent changes link on the 'tools' section on the top-left, to see all the recent changes.
- Use the New pages page, to see all recently added new pages
How can I add drivers of uncontrolled hardware like LISN's?[edit]
RadiMation® uses drivers for all devices used during an EMC measurement, even passive components. With passive components this may seem an overkill, as nothing is being changed/controlled with the device. Frequency limitation is the main reason, if RadiMation® does not know the frequency range, it can not warn you that you are making possible mistake. To add a passive component yourself, you go to the device group in the configuration window.
For example, a LISN.
- Select "Configurable LISN" and press the New button.
- Name device correctly, and press Ok.
- Select the device in the configuration window, and press Edit.
- In the device configuration window press the Advanced button.
- Change the frequency settings to match the specification of the device, and press Ok.
For all other passive devices there are configurable devices available.
I have found a problem. What should I do?[edit]
If you have found a problem in the RadiMation® software, it is best to report it to us. We will categorize the reported issue, register it in our defect database, and investigate the problem. When a workaround or solution is available, we will report this back to you.
I have another question, that is not answered yet[edit]
Just send your question by e-mail to the RadiMation® support team (radimation-support@raditeq.com), and we will give you an answer.