Difference between revisions of "Experience Levels"

From RadiWiki
Jump to: navigation, search
 
(14 intermediate revisions by 3 users not shown)
Line 22: Line 22:
 
* Able to retrieve customer information from another database
 
* Able to retrieve customer information from another database
 
* Able to change / add information items
 
* Able to change / add information items
 +
* Able to use Attenuation/Gain calbiration to determine cable loss
 
|
 
|
 
* Able to use overlapping bands in a Multiband test
 
* Able to use overlapping bands in a Multiband test
 
* Able to optimize the change order in Multiband tests
 
* Able to optimize the change order in Multiband tests
 
* Able to export graphs and data to other software programs
 
* Able to export graphs and data to other software programs
* Able to use TSF file protection and user rights permissions
+
* Able to use TSF file protection and [[Chapter_2#User rights and installation| user rights permissions]]
 
|
 
|
 
* [[RadiMation Application Note 100|Able to configure and use the Enhanced status window]]
 
* [[RadiMation Application Note 100|Able to configure and use the Enhanced status window]]
Line 41: Line 42:
 
|
 
|
 
* Able to evaluate and improve total test time
 
* Able to evaluate and improve total test time
* Able to apply the [[How to apply the field correction factor|Field Correction factor]]
+
* [[How to apply the field correction factor| Able to apply the Field Correction factor]]
 
|-
 
|-
 
![[Conducted Immunity]]
 
![[Conducted Immunity]]
Line 105: Line 106:
 
* Able to update device drivers
 
* Able to update device drivers
 
* Able to create and configure testsites
 
* Able to create and configure testsites
* Able to add / modify test engineers
+
* [[Chapter_2#Test_engineers| Able to add / modify Test Engineers]]
 
|  
 
|  
 
* Able to configure {{RadiMation}} for usage on a network
 
* Able to configure {{RadiMation}} for usage on a network
Line 113: Line 114:
 
|
 
|
 
* [[EUT Information|Able to configure default EUT Information Items]]
 
* [[EUT Information|Able to configure default EUT Information Items]]
 +
* [[Auto create EUT directory]]
 
* [[:Category:Advanced_Option|Able to modify Advanced Options]]
 
* [[:Category:Advanced_Option|Able to modify Advanced Options]]
 
* Tuning and tweaking by using TUNING.INI
 
* Tuning and tweaking by using TUNING.INI
Line 122: Line 124:
 
|
 
|
 
* Able to add and configure device drivers for measurement equipment
 
* Able to add and configure device drivers for measurement equipment
* Aware of diffences between spectrum analyzer / scanning receiver / receiver
+
* Aware of diffences between spectrum analyser / scanning receiver / receiver
 
|
 
|
 
* Able to create [http://forum.radimation.com/viewtopic.php?f=3&t=126 NI I/O Trace], RadiLog and Agilent Monitor files.
 
* Able to create [http://forum.radimation.com/viewtopic.php?f=3&t=126 NI I/O Trace], RadiLog and Agilent Monitor files.
Line 131: Line 133:
 
|
 
|
 
* Able to use configurable device drivers to control equipment
 
* Able to use configurable device drivers to control equipment
 +
* Able to use EUT Status interface to interface with EUT Controller
 
|-  
 
|-  
 
!{{RadiMation}} Free
 
!{{RadiMation}} Free
Line 136: Line 139:
 
* Able to connect to devices and perform measurements
 
* Able to connect to devices and perform measurements
 
|
 
|
* [[RadiMation Application Note 102|Able to perform ETSI EN 300328 burst measurements]]
+
* [[RadiMation Application Note 102|Able to perform ETSI EN 300 328 burst measurements]]
 
|
 
|
 
|
 
|
 
|}
 
|}

Latest revision as of 19:44, 31 January 2024

To structure the different levels of experience with RadiMation, we created an experience level matrix:

Novice Competent Master Expert
General
  • Able to create a new EUT file
  • Able to start an existing TSF
  • Able to enter / modify notes
  • Able to view test data
  • Able to start a sequence
  • Able to use overlapping bands in a Multiband test
  • Able to optimize the change order in Multiband tests
  • Able to export graphs and data to other software programs
  • Able to use TSF file protection and user rights permissions
Radiated Immunity
  • Able to perform a calibration
  • Able to perform a 16 point UFA calculation
  • Aware of different modulation types
  • Able to use multiple test-levels and limits
  • Able to perform minimum performance testing
Conducted Immunity
  • Able to perform a calibration
  • Aware of different modulation types
  • Able to use multiple test-levels and limits
  • Able to perform minimum performance testing
  • Able to evaluate and improve total test time
Pulsed Immunity
Radiated Emission
  • Able to create / modify limit lines
  • Aware of receiver settings and consequences
Conducted Emission
  • Able to create / modify limit lines
  • Aware of receiver settings and consequences
  • Able to use continuous measurement
  • Able to use graph comparisons between multiple tests
Report Generator
  • Able to generate a report from an existing template
Configuration / Installation
  • Able to configure RadiMation® for usage on a network
  • Able to add actions to a testsite
  • Able to configure a customer database interface
  • Able to configure basic standards and product standards
Measurement equipment
  • Able to add and configure device drivers for measurement equipment
  • Aware of diffences between spectrum analyser / scanning receiver / receiver
  • Able to create NI I/O Trace, RadiLog and Agilent Monitor files.
  • Able to optimize powermeter and field sensor monitoring settings
  • Able to configure automatically controlled LISN's
  • Able to configure switch matrixes
  • Able to apply corrections to the measurement equipment
  • Able to use configurable device drivers to control equipment
  • Able to use EUT Status interface to interface with EUT Controller
RadiMation® Free
  • Able to connect to devices and perform measurements