Experience Levels: Difference between revisions

From RadiWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 38: Line 38:
|
|
* Able to use multiple [http://forum.radimation.com/viewtopic.php?f=5&t=81| test-levels] and limits
* Able to use multiple [http://forum.radimation.com/viewtopic.php?f=5&t=81| test-levels] and limits
* [http://forum.radimation.com/viewtopic.php?f=6&t=516&p=1041&hilit=export#p1041| Able to perform minimum performance testing]
* Able to perform minimum performance testing
|
|
* Able to evaluate and improve total test time
* Able to evaluate and improve total test time

Revision as of 12:22, 4 March 2019

To structure the different levels of experience with RadiMation, we created an experience level matrix:

Novice Competent Master Expert
General
  • Able to create a new EUT file
  • Able to start an existing TSF
  • Able to enter / modify notes
  • Able to view test data
  • Able to start a sequence
  • Able to use overlapping bands in a Multiband test
  • Able to optimize the change order in Multiband tests
  • Able to export graphs and data to other software programs
  • Able to use TSF file protection and user rights permissions
Radiated Immunity
  • Able to perform a calibration
  • Able to perform a 16 point UFA calculation
  • Aware of different modulation types
  • Able to use multiple test-levels and limits
  • Able to perform minimum performance testing
Conducted Immunity
  • Able to perform a calibration
  • Aware of different modulation types
  • Able to use multiple test-levels and limits
  • Able to perform minimum performance testing
  • Able to evaluate and improve total test time
Pulsed Immunity
Radiated Emission
  • Able to create / modify limit lines
  • Aware of receiver settings and consequences
Conducted Emission
  • Able to create / modify limit lines
  • Aware of receiver settings and consequences
  • Able to use continuous measurement
  • Able to use graph comparisons between multiple tests
Report Generator
  • Able to generate a report from an existing template
Configuration / Installation
  • Able to configure RadiMation® for usage on a network
  • Able to add actions to a testsite
  • Able to configure a customer database interface
  • Able to configure basic standards and product standards
Measurement equipment
  • Able to add and configure device drivers for measurement equipment
  • Aware of diffences between spectrum analyzer / scanning receiver / receiver
  • Able to create NI I/O Trace, RadiLog and Agilent Monitor files.
  • Able to optimize powermeter and field sensor monitoring settings
  • Able to configure automatically controlled LISN's
  • Able to configure switch matrixes
  • Able to apply corrections to the measurement equipment
  • Able to use configurable device drivers to control equipment
  • Able to use EUT Status interface to interface with EUT Controller
RadiMation® Free
  • Able to connect to devices and perform measurements